Publications by authors named "Daniel O Ellert"

Purpose: To compare retentive forces of removable partial denture clasps traditionally fabricated with cobalt-chromium (CoCr) material and two computer-aided design and computer-aided manufactured (CAD/CAM) thermoplastic polymers.

Materials And Methods: Forty-eight clasp assemblies (16 CoCr, 16 polyetheretherketone (PEEK) and 16 polyetherketoneketone (PEKK) thermoplastic polymer) were fabricated for 48 mandibular tooth analogs. Individual clasps were inserted and removed on the tooth analogs utilizing a chewing simulator for 15,000 cycles to simulate 10 years of use.

View Article and Find Full Text PDF

Purpose: The purpose of this in vitro study was to evaluate the effect of software on scan time, trueness, and precision of digital scans created using the CEREC Omnicam.

Material And Methods: Sixty scans (20 scans/provider) of a standard reference cast were made by three different providers using the CEREC Omnicam with both CEREC Ortho 1.2.

View Article and Find Full Text PDF

Statement Of Problem: Intraoral scanners have shown varied results in complete-arch applications.

Purpose: The purpose of this in vitro study was to evaluate the complete-arch accuracy of 4 intraoral scanners based on trueness and precision measurements compared with a known reference (trueness) and with each other (precision).

Material And Methods: Four intraoral scanners were evaluated: CEREC Bluecam, CEREC Omnicam, TRIOS Color, and Carestream CS 3500.

View Article and Find Full Text PDF