This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies.
View Article and Find Full Text PDFThe personalised oncology paradigm remains challenging to deliver despite technological advances in genomics-based identification of actionable variants combined with the increasing focus of drug development on these specific targets. To ensure we continue to build concerted momentum to improve outcomes across all cancer types, financial, technological and operational barriers need to be addressed. For example, complete integration and certification of the 'molecular tumour board' into 'standard of care' ensures a unified clinical decision pathway that both counteracts fragmentation and is the cornerstone of evidence-based delivery inside and outside of a research setting.
View Article and Find Full Text PDFBackground: Respiratory motion artefacts are a pitfall in thoracic PET/CT imaging. A source of these motion artefacts within PET images is the CT used for attenuation correction of the images. The arbitrary respiratory phase in which the helical CT ( ) is acquired often causes misregistration between PET and CT images, leading to inaccurate attenuation correction of the PET image.
View Article and Find Full Text PDFBackground: Investigate the potential benefits of sequential deployment of two deep learning (DL) algorithms namely DL-Enhancement (DLE) and DL-based time-of-flight (ToF) (DLT). DLE aims to enhance the rapidly reconstructed ordered-subset-expectation-maximisation algorithm (OSEM) images towards block-sequential-regularised-expectation-maximisation (BSREM) images, whereas DLT aims to improve the quality of BSREM images reconstructed without ToF. As the algorithms differ in their purpose, sequential application may allow benefits from each to be combined.
View Article and Find Full Text PDFThe British Nuclear Medicine Society (BNMS) has developed a Research Strategy framework led by the Research Champions of the BNMS and overseen by the BNMS Research and Innovation Committee. The objectives of the Research Strategy are to improve translation of cutting-edge nuclear medicine research from bench to bedside, the implementation of state-of-the-art multimodality technologies and to enhance multicentre radionuclide research in the UK. It strives to involve patients and the public in radionuclide research and to contribute to and work with the multi-professional national and international organisations involved in research with an ultimate aim to improve nuclear medicine services, and patients' outcomes and care.
View Article and Find Full Text PDFPurpose: Nuclear medicine imaging modalities like computed tomography (CT), single photon emission CT (SPECT) and positron emission tomography (PET) are employed in the field of theranostics to estimate and plan the dose delivered to tumors and the surrounding tissues and to monitor the effect of the therapy. However, therapeutic radionuclides often provide poor images, which translate to inaccurate treatment planning and inadequate monitoring images. Multimodality information can be exploited in the reconstruction to enhance image quality.
View Article and Find Full Text PDFBackground: This work aimed to determine the implications of the variability in estimated glomerular filtration rate (eGFR) for the prediction of measured GFR (mGFR) for selection of sampling time-point in single-sample 99m Tc-diethylene-triamine-pentaacetate (DTPA) mGFR.
Methods: Patient studies were used to compare eGFR and mGFR ( n = 282). The eGFR was calculated using the Chronic Kidney Disease Epidemiology Collaboration 2009 equation, from serum creatinine values measured in the laboratory ( n = 27) or using a point-of-care testing device ( n = 255).
Positron emission tomography (PET)/computed tomography (CT) using the radiotracer 18F-Fluoromisonidazole (FMISO) has been widely employed to image tumour hypoxia and is of interest to help develop novel hypoxia modifiers and guide radiation treatment planning. Yet, the optimal post-injection (p.i.
View Article and Find Full Text PDFPurpose: Gliomas are the most commonly occurring brain tumour in adults and there remains no cure for these tumours with treatment strategies being based on tumour grade. All treatment options aim to prolong survival, maintain quality of life and slow the inevitable progression from low-grade to high-grade. Despite imaging advancements, the only reliable method to grade a glioma is to perform a biopsy, and even this is fraught with errors associated with under grading.
View Article and Find Full Text PDFIdiopathic rapid eye movement sleep behaviour disorder (iRBD) has now been established as an important marker of the prodromal stage of Parkinson's disease and related synucleinopathies. However, although dopamine transporter single photon emission computed tomography (SPECT) has been used to demonstrate the presence of nigro-striatal deficit in iRBD, quantifiable correlates of this are currently lacking. Sensitivity to rewarding stimuli is reduced in some people with Parkinson's disease, potentially contributing to aspects of the neuropsychiatric phenotype in these individuals.
View Article and Find Full Text PDFBackground: The 2018 BNMS Glomerular Filtration Rate (GFR) guidelines recommend a single-sample technique with the sampling time dictated by the expected renal function, but this is not known with any accuracy before the test. We aimed to assess whether the sampling regime suggested in the guidelines is optimal and determine the error in GFR result if the sample time is chosen incorrectly. We can then infer the degree of flexibility in the sampling regime.
View Article and Find Full Text PDFThe Ionising Radiation (Medical Exposure) Regulations require employers to appoint suitable medical physics experts (MPE) for nuclear medicine services, and they also define the areas where MPEs are required to provide advice and specify matters that they must contribute towards. Applications for employer licences under IR(ME)R require employers to specify the level of MPE support available and if this is provided by onsite MPEs or remotely. Assessment of these applications by the Administration of Radioactive Substances Advisory Committee (ARSAC) has highlighted variability in the levels of MPE support being provided for similar services across the UK.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
September 2022
Purpose: To improve the quantitative accuracy and diagnostic confidence of PET images reconstructed without time-of-flight (ToF) using deep learning models trained for ToF image enhancement (DL-ToF).
Methods: A total of 273 [F]-FDG PET scans were used, including data from 6 centres equipped with GE Discovery MI ToF scanners. PET data were reconstructed using the block-sequential-regularised-expectation-maximisation (BSREM) algorithm with and without ToF.
Respiratory motion degrades the quantification accuracy of PET imaging by blurring the radioactivity distribution. In the case of post-SIRT PET-CT verification imaging, respiratory motion can lead to inaccuracies in dosimetric measures. Using an anthropomorphic phantom filled with Y at a range of clinically relevant activities, together with a respiratory motion platform performing realistic motions (10-15 mm amplitude), we assessed the impact of respiratory motion on PET-derived post-SIRT dosimetry.
View Article and Find Full Text PDFBackground: Tumour hypoxia promotes an aggressive tumour phenotype and enhances resistance to anticancer treatments. Following the recent observation that the mitochondrial inhibitor atovaquone increases tumour oxygenation in NSCLC, we sought to assess whether atovaquone affects tumour subregions differently depending on their level of hypoxia.
Methods: Patients with resectable NSCLC participated in the ATOM trial (NCT02628080).
This article reviews the current evolution and future directions in PET/CT technology focusing on three areas: time of flight, image reconstruction, and data-driven gating. Image reconstruction is considered with advances in point spread function modelling, Bayesian penalised likelihood reconstruction, and artificial intelligence approaches. Data-driven gating is examined with reference to respiratory motion, cardiac motion, and head motion.
View Article and Find Full Text PDFThe Internal Dosimetry User Group (IDUG) is an independent, non-profit group of medical professionals dedicated to the promotion of dosimetry in molecular radiotherapy (www.IDUG.org.
View Article and Find Full Text PDFPurpose: To enhance the image quality of oncology [F]-FDG PET scans acquired in shorter times and reconstructed by faster algorithms using deep neural networks.
Methods: List-mode data from 277 [F]-FDG PET/CT scans, from six centres using GE Discovery PET/CT scanners, were split into ¾-, ½- and ¼-duration scans. Full-duration datasets were reconstructed using the convergent block sequential regularised expectation maximisation (BSREM) algorithm.
Purpose: Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time-activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
August 2021
We present 2 cases of iatrogenic retinal penetration from intravitreal (IVT) injections in a retrospective noncomparative case series of 2 patients. The first patient, an 81-year-old Caucasian male, developed dense vitreous hemorrhage soon after receiving an IVT bevacizumab injection for macular edema from central retinal vein occlusion. A 25-g vitrectomy 1 week later showed a retinal hole surrounded by fresh hemorrhages in the same quadrant as the IVT injection.
View Article and Find Full Text PDF