J Biomed Mater Res B Appl Biomater
December 2024
Despite high total knee arthroplasty (TKA) survivorship after 10 years (92%-99%), a gap persists where patient satisfaction lags clinical success. Additionally, while cobalt chrome molybdenum (CoCrMo) use decreases in primary total hip arthroplasty, the alloy continues to be widely used in TKA femoral components. In vivo, CoCrMo degradation may be associated with adverse local tissue reactions (ALTR) and compared with the hip, the damage mechanisms that may release metal in the knee and the potential biological effects remain poorly understood.
View Article and Find Full Text PDFWith freshwater resources becoming increasingly scarce, the photocatalytic seawater splitting for hydrogen production has garnered widespread attention. In this study, a novel photocatalyst consisting of a Cu core coated is introduced with N-doped C and decorated with single Co atoms (Co-NC@Cu) for solar to hydrogen production from seawater. This catalyst, without using noble metals or sacrificial agents, demonstrates superior hydrogen production effficiency of 9080 µmolgh, i.
View Article and Find Full Text PDFvan der Waals (vdW) layered materials have been shown to have excellent optoelectronic properties relevant to photovoltaics. Despite their promise, the demonstrated efficiencies of vdW material solar cells remain low and are seldom supported by statistics or spectral quantum efficiency analysis. In this study, we utilize a p-type WSe absorber, forming a solar cell with a transparent front InO electron contact, and a rear Pd reflector/hole contact.
View Article and Find Full Text PDFLuminescent coupling (LC) is a key phenomenon in monolithic tandem solar cells. This study presents a nondestructive technique to quantitatively evaluate the LC effect, addressing a gap in the existing predictions made by optical modeling. The method involves measuring the ratio of photons emitted from the high bandgap top cell that escape through the rear, contributing additional current to the bottom cell, and to those escaping from the front side of top cell.
View Article and Find Full Text PDFBackground: The first generation of titanium nitride (TiN) coatings for orthopaedic implants was clinically introduced in the 1990s because of their promising biocompatibility, wear resistance, and corrosion resistance. This study evaluated the in vivo performance of early TiN-coated knee and hip implants, focusing on the bearing surfaces and mechanisms of in vivo damage.
Methods: There were 13 TiN-coated implants (5 knee and 8 hip) retrieved from 8 patients as part of a multi-institutional implant retrieval program.
Background: After clinical introduction in 2005, sequentially annealed, highly cross-linked polyethylene (SA HXLPE) was studied for retrievals with short implantation times; however, long-term follow-ups are lacking. The objective of this study was to examine and compare the revision reasons, damage mechanisms, and oxidation indices of SA HXLPE and conventional gamma inert-sterilized (Gamma Inert) ultra-high-molecular-weight polyethylene tibial inserts implanted for >5 years.
Methods: There were 74 total knee arthroplasty tibial inserts (46 SA HXLPEs, 28 Gamma Inerts) implanted for >5 years (mean 7 ± 2 years) retrieved as part of a multicenter retrieval program.
Background: Highly cross-linked polyethylene (HXLPE) was introduced to improve wear in total hip arthroplasty, with manufacturers implementing different thermal treatments to reduce oxidation. It is important to understand how long-term time in vivo affects the wear of these materials. The purpose of this study was to investigate the wear and oxidative performance of first-generation HXLPE hip inserts implanted for greater than 10 years and compare annealed and remelted HXLPE formulations.
View Article and Find Full Text PDFAmorphous thin-film TiO prepared via atomic layer deposition (ALD) has been identified as one of the most promising materials for use in transparent passivating contacts in high-efficiency and low-cost crystalline silicon (c-Si) solar cells. As highlighted in this work, the passivation performance of ALD TiO layers strongly depends on the metal precursor used, with films prepared using TiCl recently showing the best results. However, a full understanding of how such films achieve their high level of surface passivation has not yet been demonstrated.
View Article and Find Full Text PDFComput Methods Programs Biomed
November 2023
Background And Objective: Vessel geometry and hemodynamics are intrinsically linked, whereby geometry determines hemodynamics, and hemodynamics influence vascular remodeling. Both have been used for testing clinical outcomes, but geometry/morphology generally has less uncertainty than hemodynamics derived from medical image-based computational fluid dynamics (CFD). To provide clinical utility, CFD-based hemodynamic parameters must be robust to modeling errors and/or uncertainties, but must also provide useful information not more-easily extracted from shape alone.
View Article and Find Full Text PDFBackground: Previous retrieval studies of patellar components for total knee arthroplasty focused on historical designs and polyethylene materials that are no longer clinically relevant. Therefore, this study aimed to compare revision reasons and surface damage mechanisms of conventional, gamma inert sterilized polyethylene and highly cross-linked polyethylene (HXLPE) patellar components in contemporary designs from a single manufacturer.
Methods: A total of 114 gamma inert and 76 HXLPE patellar components were gathered in a multicenter orthopaedic implant retrieval program.
Introduction: Overestimation of intracranial aneurysm neck width by 3D angiography is a recognized clinical problem, and has long been a concern for image-based computational fluid dynamics (CFD). Recently, it was demonstrated that neck overestimation in 3D rotational angiography (3DRA) could be corrected via segmentation with upsampled resolution and gradient enhancement (SURGE). Our aim was to leverage this approach to determine whether and how neck overestimation actually impacts CFD-derived hemodynamics.
View Article and Find Full Text PDFBackground: Intracranial aneurysm neck width tends to be overestimated when measured with three-dimensional rotational angiography (3DRA) compared with two-dimensional digital subtraction angiography (2D-DSA), owing to high curvature at the neck. This may affect morphological and hemodynamic analysis in support of treatment planning. We present and validate a method for extracting high curvature features, such as aneurysm ostia, during segmentation of 3DRA images.
View Article and Find Full Text PDFThe Radiation and Dust Sensor is one of six sensors of the Mars Environmental Dynamics Analyzer onboard the Perseverance rover from the Mars 2020 NASA mission. Its primary goal is to characterize the airbone dust in the Mars atmosphere, inferring its concentration, shape and optical properties. Thanks to its geometry, the sensor will be capable of studying dust-lifting processes with a high temporal resolution and high spatial coverage.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
June 2022
Purpose: Communicating complex blood flow patterns generated from computational fluid dynamics (CFD) simulations to clinical audiences for the purposes of risk assessment or treatment planning is an ongoing challenge. While attempts have been made to develop new software tools for such clinical visualization of CFD data, these often overlook established medical imaging/visualization practice and data infrastructures. Here, leveraging the clinical ubiquity of the DICOM file format, we present techniques for the translation of CFD data to DICOM series, facilitating interactive visualization in standard radiological software.
View Article and Find Full Text PDFRecent studies using high-fidelity computational fluid dynamics (CFD) have revealed high-frequency flow instabilities consistent with clinical reports of bruits and "musical murmurs", which have been speculated to contribute to aneurysm growth and rupture. We hypothesized that harmonic flow instabilities ("spectral bandedness") in aneurysm CFD data may be associated with rupture status. Before testing this hypothesis, we first present a novel method for quantifying and visualizing spectral bandedness in cardiovascular CFD datasets based on musical audio-processing tools.
View Article and Find Full Text PDFACS Appl Mater Interfaces
November 2021
It has previously been shown that ex situ phosphorus-doped polycrystalline silicon on silicon oxide (poly-Si/SiO) passivating contacts can suffer a pronounced surface passivation degradation when subjected to a firing treatment at 800 °C or above. The degradation behavior depends strongly on the processing conditions, such as the dielectric coating layers and the firing temperature. The current work further studies the firing stability of poly-Si contacts and proposes a mechanism for the observed behavior based on the role of hydrogen.
View Article and Find Full Text PDFACS Appl Mater Interfaces
July 2021
Defects and impurities in silicon limit carrier lifetimes and the performance of solar cells. This work explores the use of fluorine to passivate defects in silicon for solar cell applications. We present a simple method to incorporate fluorine atoms into the silicon bulk and interfaces by annealing samples coated with thin thermally evaporated fluoride overlayers.
View Article and Find Full Text PDFBackground: Dual mobility (DM) articulations were introduced for total hip arthroplasty to reduce the risk of instability for patients who have a high risk of dislocation. The use of DM constructs in both primary and revision total hip arthroplasty has been steadily increasing, leading to concerns regarding potential risks of fretting corrosion, polyethylene wear, metal release, and failure due to component positioning.
Methods: A total of 56 retrieved DM constructs were collected.
For Ti6Al4V orthopedic and spinal implants, osseointegration is often achieved using complex porous geometries created via additive manufacturing (AM). While AM porous titanium (pTi) has shown clinical success, concerns regarding metallic implants have spurred interest in alternative AM biomaterials for osseointegration. Insights regarding the evaluation of these new materials may be supported by better understanding the role of preclinical testing for AM pTi.
View Article and Find Full Text PDFTwo-dimensional (2D) transition-metal dichalcogenide (TMD) semiconductors exhibit many important structural and optoelectronic properties, such as strong light-matter interactions, direct bandgaps tunable from visible to near-infrared regions, flexibility and atomic thickness, quantum-confinement effects, valley polarization possibilities, and so on. Therefore, they are regarded as a very promising class of materials for next-generation state-of-the-art nano/micro optoelectronic devices. To explore different applications and device structures based on 2D TMDs, intrinsic material properties, their relationships, and evolutions with fabrication parameters need to be deeply understood, very often through a combination of various characterization techniques.
View Article and Find Full Text PDFIn the past decade, high-fidelity computational fluid dynamics (CFD) has uncovered the presence of high-frequency flow instabilities (on the order of 100 s of Hz) in a variety of cardiovascular applications. These fluctuations are typically reported as pulsatile velocity-time traces or fast-Fourier-transformed power-frequency spectra, often from a single point or at most a handful of points. Originally inspired by its use in spectral Doppler ultrasound, here we demonstrate the utility of the simplest form of time-frequency representation - the spectrogram - as a more comprehensive yet still-intuitive means of visualizing the potential harmonic complexity of pulsatile cardiovascular flows.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
November 2020
Background: The purpose of this study was to evaluate ultrahigh-molecular-weight polyethylene (UHMWPE) wear and damage from retrieved total elbow arthroplasty components and compare in vivo wear with wear produced in vitro.
Methods: Explanted total elbow components were collected at revision surgery. UHMWPE damage was characterized visually, whereas penetration and wear were quantified using micro-computed tomography and gas pycnometry.
Long-range and fast transport of coherent excitons is important for the development of high-speed excitonic circuits and quantum computing applications. However, most of these coherent excitons have only been observed in some low-dimensional semiconductors when coupled with cavities, as there are large inhomogeneous broadening and dephasing effects on the transport of excitons in their native states in materials. Here, by confining coherent excitons at the 2D quantum limit, we first observed molecular aggregation-enabled 'supertransport' of excitons in atomically thin two-dimensional (2D) organic semiconductors between coherent states, with a measured high effective exciton diffusion coefficient of ~346.
View Article and Find Full Text PDFEfficient and stable electron selective materials compatible with commercial production are essential to the fabrication of dopant-free silicon solar cells. In this work, we report an air-stable TiN (titanium nitride) polycrystalline film, deposited using radio frequency sputtering process, as an electron selective contact in silicon solar cells. TiN films deposited at 300 W and 1.
View Article and Find Full Text PDFOrganic-inorganic (O-I) heterostructures, consisting of atomically thin inorganic semiconductors and organic molecules, present synergistic and enhanced optoelectronic properties with a high tunability. Here, we develop a class of air-stable vertical O-I heterostructures comprising a monolayer of transition-metal dichalcogenides (TMDs), including WS, WSe, and MoSe, on top of tetraphenylethylene (TPE) core-based aggregation-induced emission (AIE) molecular rotors. The created O-I heterostructures yields a photoluminescence (PL) enhancement of up to ∼950%, ∼500%, and ∼330% in the top monolayer WS, MoSe, and WSe as compared to PL in their pristine monolayers, respectively.
View Article and Find Full Text PDF