Background: Misalignment to the incorrect vertebral body remains a rare but serious patient safety risk in image-guided radiotherapy (IGRT).
Purpose: Our group has proposed that an automated image-review algorithm be inserted into the IGRT process as an interlock to detect off-by-one vertebral body errors. This study presents the development and multi-institutional validation of a convolutional neural network (CNN)-based approach for such an algorithm using patient image data from a planar stereoscopic x-ray IGRT system.
Purpose: Single-isocenter multiple brain metastasis stereotactic radiosurgery is an efficient treatment modality increasing in clinical practice. The need to provide accurate, patient-specific quality assurance (QA) for these plans is met by several options. This study reviews some of these options and explores the use of the Octavius 4D as a solution for patient-specific plan quality assurance.
View Article and Find Full Text PDFPurpose: With the advent of volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) treatment techniques, the requirement for more elaborate approaches in reviewing linac components' integrity has become even more stringent. A possible solution to this challenge is to employ the usage of log files generated during treatment. The log files generated by the new generation of Elekta linacs record events at a higher frequency (25 Hz) than their predecessors, which allows for retrospective analysis and identification of subtle changes and provides another means of quality assurance.
View Article and Find Full Text PDFJ Appl Clin Med Phys
January 2019
Purpose: The Brainlab Elements treatment planning system utilizes distinct modules for treatment planning specific to stereotactic treatment sites including single or multiple brain lesions as well as spine. This work investigates the hypothesis that an optimization tailored specifically to spine can in fact create dosimetrically superior plans to those created in more general use treatment planning systems (TPS).
Methods: Ten spine patients at our institution were replanned in Brainlab Elements, Phillips Pinnacle , and Elekta Monaco.
Background And Purpose: With the increasingly prominent role of stereotactic radiosurgery in radiation therapy, there is a clinical need for robust, efficient, and accurate solutions for targeting multiple sites with one patient setup. The end-to-end accuracy of high definition dynamic radiosurgery with Elekta treatment planning and delivery systems was investigated in this study.
Materials And Methods: A patient-derived CT scan was used to create a radiosurgery plan to seven targets in the brain.
Purpose: While external beam radiotherapy treatment planning determines nearly every mechanical and dosimetric parameter of the linear accelerator (LINAC), the table coordinates in all three dimensions are generally unknown until initial patient setup at the LINAC. Knowing these parameters in advance could help verify the direction of patient shifts and prevent wrong-site errors. This study aims to determine the feasibility and accuracy of table coordinate prediction for indexed immobilization devices.
View Article and Find Full Text PDFThe purpose of this study is to perform dosimetric validation of Monaco treatment planning system version 5.1. The Elekta VersaHD linear accelerator with high dose rate flattening filter-free photon modes and electron energies was used in this study.
View Article and Find Full Text PDFThe primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed.
View Article and Find Full Text PDFPurpose: Temperature and pressure corrections are necessary to account for the varying mass of air in the sensitive volume of a vented ionization chamber (IC) when performing absolute dose measurements. Locations commonly used to measure the presumed IC air temperature may not accurately represent the chamber cavity air temperature, and phantoms undergoing temperature changes further compound the problem. Prior studies have characterized thermal equilibrium in separate phantoms for Farmer chambers alone.
View Article and Find Full Text PDFOur institution performs in vivo verification measurement for each of our total body irradiation (TBI) patients with optically stimulated luminescent dosimeters (OSLD). The lung block verification measurements were commonly higher than expected. The aim of this work is to understand this discrepancy and improve the accuracy of these lung block verification measurements.
View Article and Find Full Text PDFThe Elekta Versa HD incorporates a variety of upgrades to the line of Elekta linear accelerators, primarily including the Agility head and flattening filter-free (FFF) photon beam delivery. The completely distinct dosimetric output of the head from its predecessors, combined with the FFF beams, requires a new investigation of modeling in treatment planning systems. A model was created in Pinnacle3 v9.
View Article and Find Full Text PDFViewRay is a novel MR-guided radiotherapy system capable of imaging in near real-time at four frames per second during treatment using 0.35T field strength. It allows for improved gating techniques and adaptive radiotherapy.
View Article and Find Full Text PDFViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.
View Article and Find Full Text PDF