The role of trabeculae carneae in modulating left ventricular (LV) diastolic compliance remains unclear. The objective of this study was to determine the contribution of trabeculae carneae to the LV diastolic compliance. LV pressure-volume compliance curves were measured in six human heart explants from patients with LV hypertrophy at baseline and following trabecular cutting.
View Article and Find Full Text PDFBackground: Implantable cardioverter-defibrillators monitor intracardiac electrograms (EGMs) to discriminate between ventricular and supraventricular tachycardias. The incidence of inappropriate shocks remains high because of misclassification of the tachycardia in an otherwise hemodynamically stable individual. Coupling EGMs with an assessment of left ventricular (LV) stroke volume (SV) could help in gauging hemodynamics during an arrhythmia and reducing inappropriate shocks.
View Article and Find Full Text PDFBlood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile.
View Article and Find Full Text PDFThis paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. There are two main advantages of the admittance technique to measure volume.
View Article and Find Full Text PDFThere are two implanted heart failure warning systems incorporated into biventricular pacemakers/automatic implantable cardiac defibrillators and tested in clinical trials: right heart pressures, and lung conductance measurements. However, both warning systems postdate measures of the earliest indicator of impending heart failure: left ventricular (LV) volume. There are currently no proposed implanted technologies that can perform LV blood volume measurements in humans.
View Article and Find Full Text PDFAbstract The Scisense (London, ON, Canada) micro-manometer pressure sensor is currently being used by investigators to evaluate cardiovascular physiology in mice, but has not been validated to date. The purpose of the current study is to compare the 1.2 F Scisense pressure sensor to the current gold standard produced by Millar Instruments (Houston, TX) (1.
View Article and Find Full Text PDFThe conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine G(P) and Baan's equation calibrated with both stroke volume (SV) and cuvette.
View Article and Find Full Text PDFA classic problem in traditional conductance measurement of left ventricular (LV) volume is the separation of the contributions of myocardium from blood. Measurement of both the magnitude and the phase of admittance allow estimation of the time-varying myocardial contribution, which provides a substantial improvement by eliminating the need for hypertonic saline injection. We present in vivo epicardial surface probe measurements of electrical properties in murine myocardium using two different techniques (a digital and an analog approach).
View Article and Find Full Text PDFConf Proc IEEE Eng Med Biol Soc
June 2007
Cardiac volume can be estimated by a conductance catheter system. Both blood and myocardium are conductive, but only the blood conductance is desired. Therefore, the parallel myocardium contribution should be removed from the total measured conductance.
View Article and Find Full Text PDFConductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal. This system is based on the observation that myocardial resistivity varies with frequency, whereas blood resistivity does not.
View Article and Find Full Text PDFObjectives: The aim of this study was to evaluate the feasibility of optical coherence tomography (OCT) to identify the components of vulnerable plaques in a well-established murine model of human atherosclerosis.
Background: Although the pathologic features that predict plaque rupture at autopsy are well known, the development of a technology to identify these high risk features in vivo is lacking. OCT uses reflected light to provide histology-like images of plaque with higher resolution than competing imaging modalities.
It is unclear whether the increase in availability of substrates for energy production in diabetes can lead to enhanced systolic function early in the disease, before the onset of structural changes to the myocardium. To examine this issue, BKS.Cg-m +/+ Lepr db (db/db) mice with type 2 diabetes and wild type controls had left ventricular pressure-volume relationships determined in situ.
View Article and Find Full Text PDFBackground: It has been hypothesized that because of its rapid heart rate, the intact murine heart functions near maximal contractility in the basal state. If this hypothesis is correct, then the fast and slow components of myocardial length-dependent activation should be blunted compared with larger mammals.
Methods And Results: Mice (n=24) were anesthetized, and via an open chest, LV pressure-volume relationships were determined by a dual-frequency conductance catheter system.