Background: Coronary artery disease (CAD) burden for society is expected to steeply increase over the next decade. Improved feasibility and efficiency of preventive strategies is necessary to flatten the curve. Acute myocardial infarction (AMI) is the main determinant of CAD-related mortality and morbidity, and predominantly occurs in individuals with more advanced stages of CAD causing subclinical myocardial ischemia (obstructive CAD; OCAD).
View Article and Find Full Text PDFPurpose: To assess the repeatability and reproducibility of semiquantitative magnetic resonance (MR) perfusion analysis performed by using different software packages.
Materials And Methods: The study protocol was approved by the institutional ethics committee. Informed consent was obtained from each patient.
To assess the diagnostic value of adenosine "stress-only" myocardial perfusion MR for ischemia detection as an indicator for coronary angiography in patients without a prior myocardial infarction and a necessity to exclude ischemia. Adenosine perfusion MRI was performed at 1.5 T in 139 patients with a suspicion of ischemia and no prior myocardial infarction.
View Article and Find Full Text PDFLeft ventricular (LV) function assessment by dual-source computed tomography (DSCT) was compared with the reference standard method using magnetic resonance imaging (MRI). Accurate assessment of LV function is essential for the prediction of prognosis in cardiac disease. Thirty-four patients undergoing DSCT examination of the heart for various clinical indications underwent MRI after DSCT.
View Article and Find Full Text PDFBackground: Peripheral arterial disease (PAD) is a common disease associated with a considerably increased risk of future cardiovascular events and most of these patients will die from coronary artery disease (CAD). Screening for silent CAD has become an option with recent non-invasive developments in CT (computed tomography)-angiography and MR (magnetic resonance) stress testing. Screening in combination with more aggressive treatment may improve prognosis.
View Article and Find Full Text PDFThe purpose of this study was to assess whether accurate global left-ventricular (LV) functional parameters can be obtained by analyzing every second short-axis magnetic resonance imaging cine series instead of consecutive slices, in order to reduce post-processing time. Forty patients, were scanned on a 1.5 T MRI-system (Magnetom Sonata, Siemens Medical Systems, Erlangen, Germany) using a steady-state free precession (SSFP) sequence.
View Article and Find Full Text PDFPurpose of this study was to assess the additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress Cardiac-MR (CMR). Dobutamine Stress CMR was performed in 115 patients with an inconclusive diagnosis of myocardial ischemia on a 1.5 T system (Magnetom Avanto, Siemens Medical Systems).
View Article and Find Full Text PDFTwo parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA), which are both applied to a gradient-echo sequence. Both methods were tested on 12 patients with coronary artery disease.
View Article and Find Full Text PDF