Introduction: Percutaneous left atrial appendage occlusion (LAAO) is traditionally performed under general anesthesia with trans-esophageal echocardiography guidance. Intracardiac echo (ICE)-guided LAAO closure is increasing in clinical use. The ICE catheter is crossed into LA via interatrial septum (IAS) after the septum is dilated with LAAO delivery sheath.
View Article and Find Full Text PDFBackground: The long-term outcomes of patients with congenital and childhood complete atrioventricular block (CCAVB/CAVB) after pacemaker implantation are unclear.
Methods: We performed a meta-analysis of all the studies of CCAVB. A systematic search of PubMed and CENTRAL databases from January 1, 1967 to January 31, 2020 was performed.
Background: There are limited studies comparing the risk of osteoporosis and fractures between different direct oral anticoagulants (DOACs) and vitamin K antagonists (VKA) in non-valvular atrial fibrillation (AF). Using a network meta-analysis (NMA), we compared osteoporotic fractures among 5 different treatment arms, viz. dabigatran, rivaroxaban, apixaban, edoxaban, and VKA.
View Article and Find Full Text PDFBackground And Objectives: Persistent atrial fibrillation (PeAF) with heart failure (HF) arguably constitutes the sickest subset of atrial fibrillation (AF) patients.
Methods: A systematic search was made in PubMed, Embase, and Scopus databases. Network meta-analysis (NMA) of PeAF patients with systolic HF comparing all-cause mortality, change in HF-related quality of life (QoL) and hospitalization due to heart failure (HHF) were performed among catheter ablation (CA) of AF, rate-controlling drugs (RCDs), anti-arrhythmic drugs (AADs), and atrio-ventricular nodal ablation (AVNA) using Bayesian random effect model.
J Cardiovasc Electrophysiol
May 2021
The subcutaneous-implantable cardioverter-defibrillator (S-ICD) and its electrode were developed to avoid long-term complications of transvenous leads in the vasculature. We report a case of unexpected, inappropriate S-ICD shocks due to oversensing of high-amplitude, nonphysiologic, electrical noise artifacts that were not preceded by high-impedance alerts or sensing electrogram noise detections. Following explant, high-magnification X-ray imaging of the S-ICD electrode demonstrated partial fracture of the distal sensing conductor located near a short radius bend in the electrode at the electrode-header interface.
View Article and Find Full Text PDFIntroduction: Emerging data suggest that cardioversion for atrial fibrillation (AF) may be associated with acute kidney injury (AKI). However, limited data are available regarding the incidence and risk factors for AKI after direct current cardioversion (DCCV) of AF.
Methods: All patients undergoing DCCV at Mayo Clinic between 2001 and 2012 for AF were prospectively enrolled in a database.
Pacing Clin Electrophysiol
February 2021
Magnetic resonance imaging (MRI) has become a commonly used non-ionizing radiation dependent imaging modality which has an excellent spatial resolution with the capability to provide physiological information. Cardiac implantable electronic devices (CIEDs) are used in modern cardiology with a frequency of 1:50 over 75 years of age and nearly one in three people in this population required MRI during their lifetime. Changes in the CIED structure, electronics, and algorithms paired with changes in the protocol design of MRI have created a relatively safe environment for performing MRI in patients with CIED.
View Article and Find Full Text PDFBackground: Magnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.
Methods: This is a single-center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database.
J Cardiovasc Electrophysiol
September 2020
Ventricular arrhythmia (VA) is a rare complication of cardiac resynchronization therapy (CRT). Little is known about ventricular proarrhythmia related to the pacing vector of CRT. This case report describes the elimination of ventricular arrythmia using biventricular pacing in a patient with VT-storm related to LV only pacing as part of the AdaptivCRT algorithm (Medtronic Inc).
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2020
Introduction: Venous stenosis is a well-recognized complication of transvenous leads (TVLs) that is encountered during lead revisions or device upgrades. We here report the outcomes of TVL placement facilitated by fibroplasty or tunneling (TUN) procedure.
Methods: We conducted a single-center retrospective cohort study of all patients undergoing TVL implantation requiring fibroplasty or TUN from 2005 to 2017.
Indian Pacing Electrophysiol J
March 2020
Background: Voltage mapping is critical to define substrate during ablation. In ventricular tachycardia, abnormal potentials may be targets. However, wavefront of activation could impact local signal characteristics.
View Article and Find Full Text PDFIntroduction: Myocardial infarction (MI) is associated with an increase in subsequent heart failure (HF), recurrent ischemic events, sudden cardiac arrest, and ventricular arrhythmias (SCA-VA). The primary objective of the study to determine the role of intercurrent HF and ischemic events on the development of SCA-VA following first type I MI.
Methods And Results: A retrospective cohort study of patients experiencing first type 1 MI in Olmsted County, Minnesota (2002-2012) was conducted by identifying patients using the medical records linkage system (Rochester epidemiology project).
Background: During magnetic resonance imaging (MRI), cardiac implantable electronic device (CIED) leads can be antennae to focus energy onto myocardium, leading to heating and arrhythmias. Clinical data on thoracic MRI safety for patients with legacy devices are limited.
Objective: The purpose of this study was to identify patients undergoing thoracic MRI with legacy devices, compare the incidence of adverse events of those patients with control patients undergoing brain MRI with legacy devices, and compare paired cardiac troponin T (cTnT) values.
Background: Typical atrial flutter involving the cavotricuspid isthmus (CTI) is the most common reentrant arrhythmia in congenital heart disease and ablation is effective in its management. However, congenital heart disease patients often require surgical interventions on their tricuspid valve that utilize prosthetic material, making CTI ablation technically challenging.
Objective: To describe the techniques and outcomes of CTI ablation in the presence of prior tricuspid valve repair or replacement.
Purpose: There is a significant variation in the clinical approach of initiation and dose adjustment of dofetilide in atrial fibrillation (AF). Excessive QT prolongation could predispose patients to torsades de pointes (TdP), which can be fatal.
Methods: We performed a retrospective case-control study at Mayo Clinic Rochester (January 1, 2003 to December 31, 2016).
Purpose: This study aimed to assess the risk of procedure-related complications of percutaneous epicardial access (EpiAcc) for radiofrequency catheter ablation (RFA) of ventricular arrhythmias (VAs) in patients chronically treated oral anticoagulants (OACs) with warfarin compared to those not on OACs.
Methods: We analyzed 205 patients (53 ± 16 years, 155 males) undergoing percutaneous EpiAcc as part of an RFA for VAs, and compared the outcome between patients chronically on OACs with warfarin (OAC group) and those without (non-OAC group).
Results: Forty-seven patients (23%) were chronically treated on OACs before their procedure.
HeartRhythm Case Rep
September 2018
Background: Sleep duration has been shown to be associated with all-cause mortality; however, its relationship with cause-specific fatal events remains uncertain. We examined the relationship between sleep duration and risk of fatal coronary heart disease, sudden cardiac death, cancer-related death, and all-cause mortality.
Methods: Sleep duration was self-reported at baseline examinations performed between March 20, 1984, and December 5, 1989, in 2361 men aged 42-61 years from the Kuopio Ischemic Heart Disease study.
Background: During magnetic resonance imaging (MRI), abandoned leads may act as antennae that result in tissue heating and arrhythmia induction.
Objective: The purpose of this study was to assess the safety of MRI in patients with abandoned leads, with the addition of cardiac troponin T (cTnT) assessment to screen for myocardial damage.
Methods: We reviewed our prospectively collected database of patients with cardiovascular implantable electronic devices (CIEDs) undergoing MRI between 2008 and 2017 at Mayo Clinic, Rochester, MN, and selected patients who had abandoned leads.