Background: Pre-biopsy multiparametric magnetic resonance imaging (mpMRI) of the prostate is used to conduct targeted prostate biopsy (TB), guided by ultrasound and registered (fused) to the MRI. Systematic biopsy (SB) continues to be used together with TB or in mpMRI-negative patients. There is insufficient evidence on how to use SB to inform clinical decision-making in the mpMRI era.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
March 2024
Purpose: Bone biopsies are currently conducted under computed tomography (CT) guidance using a battery-powered drill to obtain tissue samples for diagnosis of suspicious bone lesions. However, this procedure is suboptimal as images produced under CT lack soft tissue discrimination and involve ionizing radiation. Therefore, our team developed an MRI-safe pneumatic drill to translate this clinical workflow into the MR environment, which can improve target visualization and eliminate radiation exposure.
View Article and Find Full Text PDFObjective: Use of medical devices in the magnetic resonance environment is regulated by standards that include the ASTM-F2213 magnetically induced torque. This standard prescribes five tests. However, none can be directly applied to measure very low torques of slender lightweight devices such as needles.
View Article and Find Full Text PDFAccurate estimation of stone fragment size during ureteroscopic lithotripsy procedures facilitates operative efficiency and predicts the safety of fragment extraction or spontaneous passage. Using a novel stone measurement software application, this study assesses the feasibility of performing integrated real-time digital stone measurement during ureteroscopy. This workflow feasibility study was conducted in two phases.
View Article and Find Full Text PDFIn recent years, there has been increasing interest in the use of ultrasound guidance for endoscopic and percutaneous procedures. Kidney mockups could be used for training, however, available mockups are normally incompatible with ultrasound imaging. We developed a reproducible method to manufacture an ultrasound-compatible collecting system mockup that can be made at urology laboratories.
View Article and Find Full Text PDFMinim Invasive Ther Allied Technol
August 2019
Needle insertion is a common component of most diagnostic and therapeutic interventions. Needles with asymmetrically sharpened points such as the bevel point are ubiquitous. Their insertion path is typically curved due to the rudder effect at the point.
View Article and Find Full Text PDFWe present a robot-assisted approach for transrectal ultrasound (TRUS) guided prostate biopsy. The robot is a hands-free probe manipulator that moves the probe with the same 4 DoF that are used manually. Software was developed for three-dimensional (3-D) imaging, biopsy planning, robot control, and navigation.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
January 2019
Rationale And Objectives: We have designed and constructed an MR-safe robot made entirely of nonmetallic components with pneumatic actuators and optical encoders. The robot was developed to enable bone biopsies to be performed under magnetic resonance imaging (MRI) guidance in pediatric patients. The purpose of this study was to show the feasibility of using the robot for biopsy of the femur and tibia in a cadaver leg.
View Article and Find Full Text PDFIntroduction: CT is the gold standard for visualizing renal and ureteral calculi. CT three-dimensional reformatting allows for automatic, accurate, and reliable measurement of stone size, volume, density, and location. In this study, we aimed to develop and test a software platform capable of calculating a battery of clinically important urinary stone parameters at the point-of-care (POC).
View Article and Find Full Text PDFBackground: In image-guided robotic interventions, an error component is related to the positioning error of the manipulator. Therefore, measuring the kinematic error is required during robot development. However, no specialized measurement device exists for this task.
View Article and Find Full Text PDFIntroduction: Currently, stone size cannot be accurately measured while performing flexible ureteroscopy (URS). We developed novel software for ureteroscopic, stone size measurement, and then evaluated its performance.
Methods: A novel application capable of measuring stone fragment size, based on the known distance of the basket tip in the ureteroscope's visual field, was designed and calibrated in a laboratory setting.
Rationale And Objectives: Our research team has developed a magnetic resonance imaging (MRI)-compatible robot for long bone biopsy. The robot is intended to enable a new workflow for bone biopsy in pediatrics under MRI imaging. Our long-term objectives are to minimize trauma and eliminate radiation exposure when diagnosing children with bone cancers and bone infections.
View Article and Find Full Text PDFIEEE ASME Trans Mechatron
February 2017
Compatibility of mechatronic devices with the MR environment has been a very challenging engineering task. After over a decade of developments, we report the successful translation to clinical trials of our MR Safe robot technology. MrBot is a 6-degree-of-freedom, pneumatically actuated robot for transperineal prostate percutaneous access, built exclusively of electrically nonconductive and nonmagnetic materials.
View Article and Find Full Text PDFObjective: To evaluate safety and feasibility in a first-in-human trial of a direct magnetic resonance imaging (MRI)-guided prostate biopsy using a novel robotic device.
Methods: MrBot is an MRI-safe robotic device constructed entirely with nonconductive, nonmetallic, and nonmagnetic materials and developed by our group. A safety and feasibility clinical trial was designed to assess the safety and feasibility of a direct MRI-guided biopsy with MrBot and to determine its targeting accuracy.
IEEE Trans Biomed Eng
January 2018
We report the development of a new robotic system for direct image-guided interventions (DIGI; images acquired at the time of the intervention). The manipulator uses our previously reported pneumatic step motors and is entirely made of electrically nonconductive, nonmetallic, and nonmagnetic materials. It orients a needle-guide with two degrees of freedom (DoF) about a fulcrum point located below the guide using an innovative remote center of motion parallelogram type mechanism.
View Article and Find Full Text PDFThe cancer community continues to search for an efficient and cost-effective technique to isolate and characterize circulating cells (CTCs) as a 'real-time liquid biopsy'. Existing methods to isolate and analyze CTCs require various transfer, wash, and staining steps that can be time consuming, expensive, and led to the loss of rare cells. To overcome the limitations of existing CTC isolation strategies, we have developed an inexpensive 'lab on a chip' device for the enrichment, staining, and analysis of rare cell populations.
View Article and Find Full Text PDFObjective: The common sextant prostate biopsy schema lacks a three-dimensional (3D) geometric definition. The study objective was to determine the influence of the geometric distribution of the cores on the detection probability of prostate cancer (PCa).
Methods: The detection probability of significant (>0.
We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots.
View Article and Find Full Text PDFPurpose Of Review: To present the recent advances in needle guidance and robotic ultrasound technology which are used for prostate cancer (PCa) diagnosis and management.
Recent Findings: Prostate biopsy technology has remained relatively unchanged. Improved needle localization and precision would allow for better management of this common disease.
Objectives: To study the feasibility and safety of using a magnetic resonance imaging (MRI)-safe robot for assisting MRI-guided transrectal needle placement and biopsy in the prostate, using a canine model. To determine the accuracy and precision afforded by the use of the robot while targeting a desired location in the organ.
Materials And Methods: In a study approved by the Institutional Animal Care and Use Committee, six healthy adult male beagles with prostates of at least 15 × 15 mm in size at the largest transverse section were chosen for the procedure.
This paper reports the development of an MRI-Safe robot for direct (interventional) MRI-guided endorectal prostate biopsy. The robot is constructed of nonmagnetic and electrically nonconductive materials, and is electricity free, using pneumatic actuation and optical sensors. Targeting biopsy lesions of MRI abnormality presents substantial clinical potential for the management of prostate cancer.
View Article and Find Full Text PDFImage-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device.
View Article and Find Full Text PDFPurpose: Transrectal ultrasound guided prostate biopsy results rely on physician ability to target the gland according to the biopsy schema. However, to our knowledge it is unknown how accurately the freehand, transrectal ultrasound guided biopsy cores are placed in the prostate and how the geometric distribution of biopsy cores may affect the prostate cancer detection rate.
Materials And Methods: To determine the geometric distribution of cores, we developed a biopsy simulation system with pelvic mock-ups and an optical tracking system.