Background: Traumatic carotid artery pseudoaneurysms (PSAs) represent a vascular anomaly with potential for serious complications, including stroke. Traditional treatments involve endovascular stenting, which may not be ideally suited to otherwise healthy vessels that have the potential to remodel. Given the limitations of smaller animal models in replicating human vasculature and the need for improved treatment modalities, this study introduces a novel swine model for the creation and evaluation of carotid PSAs.
View Article and Find Full Text PDFValvular structural deterioration is of particular concern for transcatheter aortic valve replacements due to their suspected shorter longevity and increasing use in younger patient populations. In this work we investigated the mechanical and microstructural changes in commercial TAVR valves composed of both glutaraldehyde fixed bovine and porcine pericardium (GLBP and GLPP) following accelerated wear testing (AWT) as outlined in ISO 5840 standards. This provided greater physiological relevance to the loading compared to previous studies and by utilizing digital image correlation we were able to obtain strain contours for each leaflet pre and post fatigue and identify sites of fatigue damage.
View Article and Find Full Text PDFRecruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting.
View Article and Find Full Text PDFObjective: Bioresorbable flow diverters (BRFDs) could significantly improve the performance of next-generation flow diverter technology. In the current work, magnesium and iron alloy BRFDs were prototyped and compared in terms of porosity/pore density, radial strength, flow diversion functionality, and resorption kinetics to offer insights into selecting the best available bioresorbable metal candidate for the BRFD application.
Methods: BRFDs were constructed with braided wires made from alloys of magnesium (MgBRFD) or iron (FeBRFD).
The use of flow diverters is a rapidly growing endovascular approach for the treatment of intracranial aneurysms. All FDA-approved flow diverters are composed of nitinol or cobalt-chromium, which will remain in the patient for the duration of their life. Bioresorbable flow diverters have been proposed by several independent investigators as the next generation of flow diverting devices.
View Article and Find Full Text PDFThe metallurgical engineering of bioresorbable zinc (Zn)-based medical alloys would greatly benefit from clarification of the relationships between material properties and biological responses. Here we investigate the biocompatibility of three Zn-based silver (Ag)-containing alloys, ranging from binary to quinary alloy systems. Selected binary and quinary Zn-Ag-based alloys underwent solution treatment (ST) to increase the solubility of Ag-rich phases within the Zn bulk matrix, yielding two different microstructures (one without ST and a different one with ST) with the same elemental composition.
View Article and Find Full Text PDFThe endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function.
View Article and Find Full Text PDFSince tissue elasticity can change with pathology, noninvasive assessment of elasticity has received increasing attention. Emerging methods for assessing cardiac elasticity utilize either an external source to induce propagating shear waves or intrinsic longitudinal waves created by natural cardiac events such as left ventricle stretching that occurs due to atrial kick during late diastole. However, the effect of morphological variations that occur in diseased hearts on this longitudinal stretch wave and the corresponding estimate of elasticity is not well understood and is an active area of research.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
January 2022
Endovascular plaque composition is strongly related to stent strut stress and is responsible for strut fatigue, stent failure, and possible in-stent restenosis. To evaluate the effect of plaque on artery wall resistance to expansion we performed in silico analysis of atherosclerotic vessels. We generated finite element models from in vivo intravascular ultrasound virtual histology images to determine local artery surface stiffness and determined which plaque structures have the greatest influence.
View Article and Find Full Text PDFPeripheral artery disease (PAD) results from the buildup of atherosclerotic plaque in the arterial wall, can progress to severe ischemia and lead to tissue necrosis and limb amputation. We evaluated a means of assessing PAD mechanics using ten human peripheral arteries with PAD. Pressure-inflation testing was performed at six physiological pressure intervals ranging from 10-200 mmHg.
View Article and Find Full Text PDFComputational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes.
View Article and Find Full Text PDFObjective: To characterize the properties of the audible tones produced by current left ventricular assist device (LVAD) pumps approved for use, and to ascertain if changes in those may be present in the setting of pump thrombosis.
Patients And Methods: From August 31, 2016, to January 16, 2020, LVAD recipients consented to have surface recordings obtained using a high-fidelity digital stethoscope. Audio data were analyzed using digital recording and editing software to produce an acoustic spectrogram by Fast Fourier transformation.
Peripheral stent fracture is a major precursor to restenosis of femoral artery atherosclerosis that has been treated with stent implantation. In this work, we validate a workflow for performing in silico stenting on a patient specific peripheral artery with heterogeneous plaque structure. Six human cadaveric femoral arteries were imaged ex vivo using intravascular ultrasound virtual histology (IVUS-VH) to obtain baseline vessel geometry and plaque structure.
View Article and Find Full Text PDFSeptoplasty is one of the most commonly performed operations in the head and neck. However, the reasons for septoplasty failure and the additional stress of performing a chondrotomy on the septal cartilage are not well understood. A finite element model of the nasal septum was created using a microcomputed tomography scan of the nasoseptal complex that was reconstructed into a three-dimensional model in silico.
View Article and Find Full Text PDFBackground: "Remote aspiration," using suction from the proximal internal carotid artery (ICA) to open terminus occlusions, has been reported in small case series. However, it remains unclear whether remote aspiration is feasible for middle cerebral artery occlusions in the setting of potential inflow from communicating arteries. We performed an in vitro study to assess whether suction applied at various locations proximal to an occlusion could successfully aspirate the clot.
View Article and Find Full Text PDFPatient-specific finite element (FE) modeling of atherosclerotic plaque is challenging, as there is limited information available clinically to characterize plaque components. This study proposes that for the limited data available in vivo, material properties of plaque and artery can be identified using inverse FE analysis and either a simple neo-Hookean constitutive model or assuming linear elasticity provides sufficient accuracy to capture the changes in vessel deformation, which is the available clinical metric. To test this, 10 human cadaveric femoral arteries were each pressurized ex vivo at 6 pressure levels, while intravascular ultrasound (IVUS) and virtual histology (VH) imaging were performed during controlled pull-back to determine vessel geometry and plaque structure.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
December 2019
The purpose of the work presented here was to establish an experimental testing configuration that would generate a bending compression fracture in a laboratory setting. To this end, we designed and fabricated a fixture to accommodate a three level spine segment and to be able to perform mechanical testing by applying an off-centric compressive loading to create a flexion-type motion. Forces and moments occurring during testing were measured with a six-channel load cell.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
October 2019
Purpose: Assessing the rupture probability of intracranial aneurysms (IAs) remains challenging. Therefore, hemodynamic simulations are increasingly applied toward supporting physicians during treatment planning. However, due to several assumptions, the clinical acceptance of these methods remains limited.
View Article and Find Full Text PDFQuantitative computed tomography-based finite element analysis (QCT/FEA) is a promising tool to predict femoral properties. One of the modeling parameters required as input for QCT/FEA is the elastic modulus, which varies with the location-dependent bone mineral density (ash density). The aim of this study was to develop optimized equations for the femoral elastic modulus.
View Article and Find Full Text PDFPurpose: Tissue engineered heart valves (TEHV) are being investigated to address the limitations of currently available valve prostheses. In order to advance a wide variety of TEHV approaches, the goal of this study was to develop a cardiac valve bioreactor system capable of conditioning living valves with a range of hydrodynamic conditions as well as capable of assessing hydrodynamic performance to ISO 5840 standards.
Methods: A bioreactor system was designed based on the Windkessel approach.
Cardiovasc Eng Technol
December 2018
Purpose: Advanced morphology analysis and image-based hemodynamic simulations are increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the accuracy of those results strongly depends on the quality of the vessel wall segmentation.
Methods: To evaluate state-of-the-art segmentation approaches, the Multiple Aneurysms AnaTomy CHallenge (MATCH) was announced.
Many researchers have used cadaveric fracture tests to determine the relationship between proximal femur (hip) fracture strength and a multitude of possible explanatory variables, typically considered one or two at a time. These variables include subject-specific proximal femur variables such as femoral neck areal bone mineral density (aBMD), sex, age, and geometry, as well as physiological hip fracture event variables such as fall speed and angle of impact. However, to our knowledge, no study has included all of these variables simultaneously in the same experimental dataset.
View Article and Find Full Text PDFIncomplete endothelialization of intracoronary stents has been associated with stent thrombosis and recurrent symptoms, whereas prolonged use of dual antiplatelet therapy increases bleeding-related adverse events. Facilitated endothelialization has the potential to improve clinical outcomes in patients who are unable to tolerate dual antiplatelet therapy. The objective of this study was to demonstrate the feasibility of magnetic cell capture to rapidly endothelialize intracoronary stents in a large animal model.
View Article and Find Full Text PDFThis protocol describes the method using digital image correlation to estimate cortical strain from high speed video images of the cadaveric femoral surface obtained from mechanical testing. This optical method requires a texture of many contrasting fiduciary marks on a solid white background for accurate tracking of surface deformation as loading is applied to the specimen. Immediately prior to testing, the surface of interest in the camera view is painted with a water-based white primer and allowed to dry for several minutes.
View Article and Find Full Text PDFDual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) estimates fracture strength using 3D bone mineral distribution and geometry. By using experimentally-measured femoral stiffness and strength from a one hundred sample cadaveric cohort that included variations in sex and age, we wanted to determine if QCT/FEA estimates were able to better predict the experimental variations than DXA/aBMD.
View Article and Find Full Text PDF