Trends toward the use of irradiator parameter release (also called machine-based release) put pressure on equipment manufacturers to guarantee accuracy and reliability of monitored process parameters. In the specific case of X-ray processing, relevance of these monitored parameters is questionable due to the additional difficulty coming from the fact that the X-ray converter does not have associated parameters or a monitored feedback mechanism. To bridge this gap, this article presents a novel method to verify in real-time consistency of certain X-ray field properties.
View Article and Find Full Text PDFObjectives: Prompt gamma (PG) imaging has previously been demonstrated for use in proton range verification of a brain treatment with a homogeneous target region. In this study, the feasibility of PG imaging to detect anatomic change within a heterogeneous region is presented.
Methods: A prompt gamma camera recorded several fractions of a patient treatment to the base of skull.
Int J Radiat Oncol Biol Phys
September 2017
Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode.
Methods And Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan.
More and more camera concepts are being investigated to try and seize the opportunity of instantaneous range verification of proton therapy treatments offered by prompt gammas emitted along the proton tracks. Focusing on one-dimensional imaging with a passive collimator, the present study experimentally compared in combination with the first, clinically compatible, dedicated camera device the performances of instances of the two main options: a knife-edge slit (KES) and a multi-parallel slit (MPS) design. These two options were experimentally assessed in this specific context as they were previously demonstrated through analytical and numerical studies to allow similar performances in terms of Bragg peak retrieval precision and spatial resolution in a general context.
View Article and Find Full Text PDFBackground And Purpose: To improve precision of particle therapy, in vivo range verification is highly desirable. Methods based on prompt gamma rays emitted during treatment seem promising but have not yet been applied clinically. Here we report on the worldwide first clinical application of prompt gamma imaging (PGI) based range verification.
View Article and Find Full Text PDFPurpose: To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron.
Methods: An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone.
Background And Purpose: To investigate the use of a fast analytical prediction algorithm in the evaluation of the accuracy in Bragg peak position estimation using prompt gamma imaging in realistic anatomies.
Material And Methods: Brain, nasal cavity and lung spot scanning treatments were planned on an anthropomorphic phantom. Plan delivery in a clinical proton therapy facility was monitored using a prompt gamma camera.
Ion beam therapy promises enhanced tumour coverage compared to conventional radiotherapy, but particle range uncertainties significantly blunt the achievable precision. Experimental tools for range verification in real-time are not yet available in clinical routine. The prompt gamma ray timing method has been recently proposed as an alternative to collimated imaging systems.
View Article and Find Full Text PDFProton range monitoring may facilitate online adaptive proton therapy and improve treatment outcomes. Imaging of proton-induced prompt gamma (PG) rays using a knife-edge slit collimator is currently under investigation as a potential tool for real-time proton range monitoring. A major challenge in collimated PG imaging is the suppression of neutron-induced background counts.
View Article and Find Full Text PDFPurpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry.
View Article and Find Full Text PDFIt was proposed recently that time-resolved dose measurements during proton therapy treatment by passively scattered beams may be used for in vivo range verification. The method was shown to work accurately in a water tank. In this paper, we further evaluated the potential of the method for more clinically relevant situations where proton beams must pass through regions with significant tissue heterogeneities.
View Article and Find Full Text PDF