An advanced design of a denuder impactor (DI) sampler has been developed for characterization of possible airborne isocyanate exposure in different particle size fractions. The sampler is equipped with 12 different parallel denuder tubes, 4 impaction stages with the cut-off values (d50) of: 9.5, 4, 2.
View Article and Find Full Text PDFThe performance of a dry sampler, with an impregnated denuder in series with a glass fibre filter, using di-n-butylamine (DBA) for airborne isocyanates (200ml min(-1)) is investigated and compared with an impinger flask with a glass fibre filter in series (1 l min(-1)). An exposure chamber containing 1,6-hexamethylene diisocyanate (HDI), isophorone diisocyanate (IPDI), and 2,4- and 2,6-toluene diisocyanate (TDI) in the concentration range of 5-205 μg m(-3) [0.7-33 p.
View Article and Find Full Text PDFA method is presented for the determination of aromatic amines in aqueous extracts of polyurethane (PUR) foam. The method is based on the extraction of PUR foam using aqueous acetic acid (0.1%, w/v) followed by determination of extracted aromatic amines using hydrophilic interaction liquid chromatography (HILIC) and tandem mass spectrometry (MS/MS) with positive electrospray ionisation.
View Article and Find Full Text PDFIn some industries, the temperature and the humidity will vary greatly between different work places, such as outdoor work in arctic or tropical climates. There is therefore a need to test respirator filters at conditions that simulate conditions that are relevant for the industries that they are used in. Filter cartridges were exposed to controlled atmospheres of varying isocyanate concentration, air humidity, and temperature in an exposure chamber.
View Article and Find Full Text PDFIsocyanates in the workplace atmosphere are typically present both in gas and particle phase. The health effects of exposure to isocyanates in gas phase and different particle size fractions are likely to be different due to their ability to reach different parts in the respiratory system. To reveal more details regarding the exposure to isocyanate aerosols, a denuder-impactor (DI) sampler for airborne isocyanates was designed.
View Article and Find Full Text PDFA new type of isocyanate sampler has been used to investigate aging aerosols generated during thermal degradation of polyurethane (PUR). The sampler consists of a denuder connected in series with a three-stage cascade impactor and a filter. The denuder collects gas-phase isocyanates.
View Article and Find Full Text PDFThe solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.
View Article and Find Full Text PDFAn air sampling method for simultaneous determination of organic acid anhydrides and isocyanates is presented. Air samples are collected in impinger flasks filled with 0.01 M di-n-butylamine (DBA) in a mixture of toluene-acetonitrile (7:3, v/v) with a 13 millimetre glass fibre filter in series.
View Article and Find Full Text PDFA method for determination of technical grade isocyanates used in the production of polyurethane (PUR) is presented. The isocyanates in technical grade products were characterised as di-n-butylamine (DBA) derivatives using LC-MS and LC-chemiluminescent nitrogen detection (CLND) and the total isocyanate content was compared to a titration assay. For collection of isocyanates in air, an impinger-filter sampling technique with DBA as derivatisation reagent was used.
View Article and Find Full Text PDFDetermination of amines in biological samples as markers of exposure to the amines or the corresponding isocyanates is an important tool for industrial exposure assessment. In this study, a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for determination of amines in biological samples as perfluorofatty amides derivatives is presented. The method enables determination of diamines such as methylene diamine (MDA), toluene diamine (TDA), naphthalene diamine (NDA), hexamethylene diamine (HDA), isophorone diamine (IPDA), methylenedi(cyclohexylamine)(HMDA) and 4,4'-methylene-(2-chloroaniline)(MOCA) in human urine and plasma.
View Article and Find Full Text PDFInt Arch Occup Environ Health
September 2002
Objective: To test the hypothesis that exposure to thermal-degradation products of polyurethane (PUR), particularly isocyanates, induced nasal inflammation.
Methods: Thirty-eight workers -14 with a history of work-related nasal symptoms (WRS/Nose), and 15 referents without such history - exposed to sprayed and heated PUR glue, were studied with regard to biomarkers of isocyanate exposure [4,4'-diphenylmethane diisocyanate (4,4'-methylenediphenyl diisocyanate; MDI) and 2,4- and 2,6-toluene diisocyanate (TDI), determined as 4,4'-diphenylmethane (U-MDX) and 2,4- and 2,6-toluene (U-2,4 and U-2,6-TDX) diamine in hydrolysed urine and nasal lavage fluid (NAL)], inflammation [albumin; eosinophilic cationic protein (ECP); myeloperoxidase (MPO) and cells in NAL], serum IgG specific for MDI (S-IgG-MDI) and TDI (S-IgG-TDI), and nose symptoms. Nine unexposed office workers were also examined.
An air sampling method for the determination of isocyanates, aminoisocyanates and amines formed during the thermal degradation of polyurethane (PUR) is presented. The method is based on the collection of air samples using impinger flasks containing di-n-butylamine (DBA) in toluene with a glass fibre filter in series. Isocyanates are derivatized with DBA to urea derivatives, and amines are derivatized in a subsequent work-up procedure with ethyl chloroformate (ET) to carbamate esters.
View Article and Find Full Text PDFA method is presented for the determination of isocyanic acid (ICA), HNCO, in air samples as a di-n-butylamine (DBA) derivative. The method is based on sampling in midget impinger flasks containing 10 ml of 0.01 mol l-1 DBA in toluene.
View Article and Find Full Text PDFJ Environ Monit
October 2000
A methodology for workplace air monitoring of aromatic and aliphatic, mono- and polyisocyanates by derivatisation with di-n-butylamine (DBA) is presented. Air sampling was performed using midget impinger flasks containing 10 ml of 0.01 mol l(-1) DBA in toluene and a glass-fibre filter in series after the impinger flask, thereby providing the possibility of collecting and derivatising isocyanates in both the gas and particle phases.
View Article and Find Full Text PDFObjectives: To define the relation between exposure to polyurethane (PUR) glue, biomarkers of exposure and effect, and work related symptoms that occur at least once a week.
Methods: In a cross sectional study, 152 workers and 14 clerks in a factory with exposure to sprayed and heated PUR glue containing 4, 4'-diphenylmethane (MDI) or 1,6-hexamethylene (HDI) di-isocyanate were examined with gas chromatography-mass spectrometry (GC-MS) for metabolites of MDI in plasma (P-MDX) and urine (U-MDX), 2,4- and 2, 6-toluene di-isocyanate (TDI; P-TDX, U-TDX) and HDI in plasma and urine, specific serum IgG (S-IgG-MDI, S-IgG-HDI, and S-IgG-TDI, respectively) and IgE (S-IgE-MDI). Work related symptoms of the eyes and airways (nose or lower airways, or both), and lung function were also evaluated.
A method is presented for the determination of low molecular weight aliphatic isocyanates, methyl isocyanate (MIC), ethyl isocyanate (EIC), propyl isocyanate (PIC) and butyl isocyanate (BIC), as their dibutylamine (DBA) derivatives. The method is based on sampling in midget impinger flasks containing 10 ml of 0.01 mol l-1 DBA in toluene (as in Parts 1-4 in this series).
View Article and Find Full Text PDFThe aim of the study was to investigate biomarkers of exposure to thermal degradation products of 2,4- and 2,6-toluene diisocyanate (TDI)- and 4,4'-methylenediphenyl diisocyanate (MDI)-based polyurethane and the toxicokinetics of these products. Blood and urine were collected from 15 factory workers exposed to thermal degradation products of MDI-based polyurethane glue and TDI-based flexible foam. Four of these workers were also studied during an exposure-free period.
View Article and Find Full Text PDFA method is presented for the determination of isocyanates in polymeric methylenediphenyl diisocyanate (MDI) and related compounds formed during the thermal decomposition of polyurethane (PUR). Derivatization of isocyanates was performed in impinger flasks containing dibutylamine (DBA) with the formation of urea derivatives. Compounds containing amine groups were then derivatized with ethyl chloroformate (ET to give urethane derivatives.
View Article and Find Full Text PDFAm Ind Hyg Assoc J
March 1997
Comparative air measurements of toluene diisocyanate (TDI) were performed in a 5.6 m3 standard atmosphere and at a TDI flexible foam plant. Air samples were collected in midget impinger flasks containing 9-(N-methyl-amino-methyl)-anthracene (MAMA) in toluene and on 13-mm glass-fiber filters impregnated with MAMA and glycerol analyzed by LC-UV and with filter-tape instruments.
View Article and Find Full Text PDFDesalted plasma from a 2,4- and 2,6-toluene diisocyanate (2,4- and 2,6-TDI) exposed worker at a factory producing flexible polyurethane foam was separated and fractionated into 200 fractions using ion-exchange chromatography followed by a gel-filtration separation and fractionation into 59 fractions. The corresponding amines (to the isocyanates), 2,4- and 2,6-toluenediamine (2,4- and 2,6-TDA), were determined in each fraction after sulfuric acid hydrolysis as pentafluoropropionic anhydride derivatives by capillary gas chromatography and chemical ionisation mass spectrometry monitoring negative ions. The ion exchange fractions containing TDA (81-115) were added together and the solution was separated and fractionated on the gel-filtration column.
View Article and Find Full Text PDFBlood and urine samples were collected from six workers and two volunteers exposed to thermal degradation products from toluene diisocyanate (TDI)-based polyurethane (PUR) before and during the summer vacation. Air samples were collected on filters impregnated with 9-(N-methylaminomethyl)anthracene. The concentrations of the amines corresponding to 2,4- and 2,6-TDI, i.
View Article and Find Full Text PDFObjectives: The pathogenic basis of respiratory disorders associated with isocyanates are still obscure. One reason for this is the lack of good estimates of human exposure. In this study exposure was estimated by measurement of isocyanate metabolites in biological samples.
View Article and Find Full Text PDFObjectives: To assess the toxicokinetics of 2,4- and 2,6- toluenediisocyanate (TDI) in chronically exposed subjects.
Methods: Blood and urine, from 11 workers at two flexible foam polyurethane production plants, were sampled. By gas chromatography-mass spectrometry (GC-MS) 2,4- and 2,6-toluene diamine (TDA) were measured as pentafluoropropionic anhydride (PFPA) derivatives after acidic hydrolysis of plasma (P-TDA, ng/ml) and urine (U-TDA, microgram/h).
The object of this study was to investigate whether exposure of pipe-layers to thermal degradation products of diphenylmethane diisocyanate (MDI) could be assessed by analysing 4,4-methylenedianiline (MDA) in hydrolysed plasma and urine, and whether the genotype for N-acetylation affected these biomarker levels. Blood and urine samples were drawn from 30-pipe-layers who had been welding polyurethane (PUR) insulated pipes during the preceding 3 months. MDA in hydrolysed plasma and urine was determined with a gas chromatography-mass spectrometry technique, and genotype for N-acetylation was analysed with a polymerase chain reaction technique.
View Article and Find Full Text PDFChem Biol Interact
November 1995
An isolated, perfused, guinea pig lung model was used to investigate the molecular events which occur when a 14C-labeled TDI vapor reaches the airways. Exposure concentrations of 0.2 and 0.
View Article and Find Full Text PDF