J Int Soc Sports Nutr
December 2025
Background: The body composition of National Collegiate Athletic Association (NCAA) athletes is well documented but no such data exist for university club sports athletes. Additionally, the majority of norms for NCAA athletes were created from individual methods requiring assumptions.
Objective: This study used a four-component (4C) model to measure the body composition of university club sports athletes.
J Electr Bioimpedance
January 2022
This study aimed to evaluate the changes in impedance and estimates of body composition variables obtained from segmental multi-frequency bioelectrical impedance analysis (SMFBIA) following acute hydration change. All participants (N = 11 active adults) had SMFBIA measurements at baseline (euhydration), post-dehydration, and post-hyperhydration in an experimental repeated-measures design. Dehydration and hyperhydration trials were randomized with the opposite treatment given 24 h later.
View Article and Find Full Text PDFInt J Sport Nutr Exerc Metab
May 2021
Ultrasound is an appealing tool to assess body composition, combining the portability of a field method with the accuracy of a laboratory method. However, unlike other body composition methods, the effect of hydration status on validity is unknown. This study evaluated the impact of acute hydration changes on ultrasound measurements of subcutaneous fat thickness and estimates of body fat percentage.
View Article and Find Full Text PDFExaminers with minimal training and skill are often called upon to make body composition assessments using field methods. This study compared the interrater reliability of novice examiners for the skinfold (SKF) and A-mode ultrasound (US) methods of body composition assessment. Undergraduate Kinesiology majors (48 males, 32 females) with minimal training took both SKF and US measurements at three sites (males: chest, abdomen, thigh; females: triceps, suprailiac, thigh).
View Article and Find Full Text PDFThis case study examined the influence of a surgical metal implant on the bioelectrical impedance analysis (BIA) readings of an athlete. Single-frequency BIA using a tetrapolar electrode configuration was applied to both the right and left sides of a 23-year-old female jumper who had an 8 × 345 mm titanium alloy nail implanted in her left tibia. The metal implant reduced BIA resistance and reactance on the implanted side by 27 and 6 ohms, respectively.
View Article and Find Full Text PDFWilderness Environ Med
March 2020
Introduction: Wintertime thermal inversions can lead to the accumulation of small particulate matter (PM). Despite an association between respiratory hospital admissions and elevated PM levels, many people continue to exercise outdoors during inversions. This study compared pulmonary function and exercise performance during periods of low and high ambient PM concentrations.
View Article and Find Full Text PDFWith lower-cost devices and technologic advancements, ultrasound has been undergoing a resurgence as a method to measure subcutaneous adipose tissue. We aimed to determine whether a low-cost, 2.5-MHz amplitude (A-mode) ultrasound, designed specifically for body composition assessment, could produce subcutaneous fat thickness measurements comparable to an expensive, 12-MHz brightness (B-mode) device.
View Article and Find Full Text PDFBackground/objective: Wintertime thermal inversions in narrow mountain valleys create a ceiling effect, increasing concentration of small particulate matter (PM). Despite potential health risks, many people continue to exercise outdoors in thermal inversions. This study measured the effects of ambient PM exposure associated with a typical thermal inversion on exercise performance, pulmonary function, and biological markers of inflammation.
View Article and Find Full Text PDFThe purpose of this study was to compare power outputs of the flying start to the stationary start method on an electromagnetically-braked cycle ergometer. Twenty advanced resistance-trained men (age 24.6 ± 4.
View Article and Find Full Text PDFEarly adaptations in eccentric training show several advantages over those in concentric training. The purpose of this study was to quantify the effects of 4 weeks of multiple-joint eccentric versus traditional leg press (TLP) training on muscle strength, rate of torque development (RTD), and jump and sprint performance adaptations. Twenty-six resistance-trained adults performed either an eccentric or a TLP resistance-training program twice per week for 4 weeks.
View Article and Find Full Text PDFBackground/objectives: With technological advances, there has been a resurgence in ultrasound as a method to measure subcutaneous fat thickness. Despite the increased interest in this methodology, research comparing A-mode and B-mode ultrasound devices is lacking. Subcutaneous fat thickness measured by a low resolution (2.
View Article and Find Full Text PDFJ Strength Cond Res
June 2020
Bringhurst, RF, Wagner, DR, and Schwartz, S. Wingate anaerobic test reliability on the velotron with ice hockey players. J Strength Cond Res 34(6): 1716-1722, 2020-This study evaluated the test-retest reliability of the Wingate Anaerobic Test (WAnT) performed on a Velotron electromagnetically braked cycle ergometer for power-trained athletes and assessed whether a familiarization trial was necessary to achieve high test-retest reliability.
View Article and Find Full Text PDFObjectives: This study compared an 85-tooth versus the standard 62-tooth chainring for power outputs during a Wingate test using a Velotron electromagnetically-braked cycle ergometer.
Design: All participants completed trials using both chainring sizes in a repeated-measures cross-over design.
Methods: Resistance-trained male participants (n=20, 24.
High Alt Med Biol
September 2016
Unlabelled: Wagner, Dale R., Skyler Saunders, Brady Robertson, and John E. Davis.
View Article and Find Full Text PDFBackground: Different ultrasound parameters have been frequently used to assess changes associated with training, aging, immobilization, and neuromuscular diseases. However, an exploratory reliability analysis of the echo intensity (EI) and muscle thickness (MT) of the forearm flexors is scarce, especially in women.
Objective: The purpose of the present study was to determine the intra-rater reliability of MT and EI assessed by ultrasound in young women.
This study evaluated the validity and reliability of the BodyMetrix™ BX2000 A-mode ultrasound for estimating percent body fat (%BF) in athletes by comparing it to skinfolds and the BOD POD. Forty-five (22 males, 23 females) National Collegiate Athletic Association (NCAA) Division-I athletes volunteered for this study. Subjects were measured once in the BOD POD then twice by two technicians for skinfolds and ultrasound.
View Article and Find Full Text PDFAppl Physiol Nutr Metab
October 2015
Measured (TGVm) and predicted (TGVp) thoracic gas volumes from the BOD POD were compared in 33 lean, university athletes. On average, TGVp (3.529 L) was not significantly different (p = 0.
View Article and Find Full Text PDFInvestigations in the 1990s evaluated the influence of breathing assemblies on respiratory variables at rest and during exercise; however, research on new models of breathing assemblies is lacking. This study compared metabolic gas analysis data from a mouthpiece with a noseclip (MOUTH) and a face mask (MASK). Volunteers (7 males, 7 females; 25.
View Article and Find Full Text PDFStudies investigating the effect of rest interval length (RI) between sets on neuromuscular performance and metabolic response during power training are scarce. Therefore, the purpose of this study was to compare maximal power output, muscular activity and blood lactate concentration following 1, 2 or 3 minutes RI between sets during a squat power training protocol. Twelve resistance-trained men (22.
View Article and Find Full Text PDFBackground: High-altitude inhabitants have cardiovascular and respiratory adaptations that are advantageous for high-altitude living, but they may have impaired cognitive function. This study evaluated the influence of altitude of residence on cognitive and psychomotor function upon acute exposure to very high altitude.
Findings: Ecuadorians (31 residing at 0-1,500 m [LOW], 78 from 1,501-3,000 m [MOD], and 23 living >3,000 m [HIGH]) were tested upon their arrival to a hut at 4,860 m on Mount Chimborazo.
Session ratings of perceived exertion (SRPE) provide a valid and reliable indicator of resistance exercise session intensity. However, there is a lack of studies on the effects of resistance exercise with blood flow restriction (BFR) on SRPE. Thus, the aim of this study is to compare the effects of resistance exercise at high intensity versus low intensity with BFR on internal training load measured by SRPE.
View Article and Find Full Text PDFUltrasound has been used effectively to assess body fat for nearly 5 decades, yet this method is not known as well as many other body composition techniques. The purpose of this review is to explain the technical principles of the ultrasound method, explain the procedures for taking a measurement and interpreting the results, evaluate the reliability and validity of this method for measuring subcutaneous and visceral adipose tissue, highlight the advantages and limitations of ultrasound relative to other body composition methods, consider its utility to clinical populations, and introduce new body composition-specific ultrasound technology. The focus of this review is adipose, although various tissue thicknesses (e.
View Article and Find Full Text PDFHigh Alt Med Biol
September 2013
This study evaluated the influence of altitude of residence on orthostatic responses when exposed to high altitude. Data collection took place at the Carrel hut (4860 m) on Chimborazo in Ecuador. After being transported to the hut by vehicle, 69 people volunteered for the study.
View Article and Find Full Text PDF