We report the behavior of OptiVol2 fluid index (OVFI2) and intrathoracic impedance on remote monitoring before the appearance of signs of infection. A sustained rise in OVFI2 early after implantation reflects peri-device fluid retention.

View Article and Find Full Text PDF

A 70-year-old patient with paroxysmal atrial fibrillation underwent left atrial appendage closure. The patient experienced transient hypotension during device implantation. The procedure was abandoned because of ST-T-wave changes on electrocardiography and elevated coronary flow velocity on transesophageal echocardiography, which indicated that the device caused coronary artery compression.

View Article and Find Full Text PDF

Background: High shock impedance is associated with conversion failure among patients with subcutaneous implantable cardioverter defibrillators (S-ICD). Currently, there is no preoperative assessment method for predicting high shock impedance. This study examined the efficacy of chest computed tomography (CT) as a preoperative evaluation tool to assess the shock impedance of S-ICDs.

View Article and Find Full Text PDF

A 59-year-old man who had been diagnosed with human immunodeficiency virus-associated cardiomyopathy was referred for catheter ablation of ventricular tachycardia (VT). An electrocardiogram (ECG) waveform revealed that the clinical VT originated from the epicardium. A deceleration zone (DZ) was identified on an isochronal late activation map.

View Article and Find Full Text PDF

Background: Predictors of worsening atrioventricular valve regurgitation and left ventricular (LV) systolic function after implantation of a leadless pacemaker (LPM) remain unclear compared with those of a transvenous pacemaker (TPM).

Methods: We retrospectively analyzed 205 patients who were newly implanted with a permanent pacemaker (119 LPMs and 86 TPMs) and underwent transthoracic echocardiography before and 8 ± 5 months after implantation. We evaluated the worsening of tricuspid and mitral regurgitation (TR and MR), defined as at least one-grade aggravation in severity, and changes in LV ejection fraction (LVEF).

View Article and Find Full Text PDF

Ventricular-demand leadless pacemakers (VVI-LPMs) have often been used as an alternative to atrioventricular (AV) synchronous transvenous pacemakers (DDD-TPMs) in patients with high-grade AV block following transcatheter aortic valve replacement (TAVR). However, the clinical outcomes of this unusual usage are not elucidated. Patients who received permanent pacemakers (PPMs) owing to new-onset high-grade AV block after TAVR from September 2017 to August 2020 at a high-volume center in Japan were included in the analysis, and the clinical courses of VVI-LPM and DDD-TPM implants through 2 years of follow-up were compared retrospectively.

View Article and Find Full Text PDF

Background: Implanting a ventricular demand leadless pacemaker (VVI-LPM) for patients with non-atrial fibrillation (AF) bradyarrhythmias such as sick sinus syndrome (SSS) or high-grade (i.e., second- or third-degree) atrioventricular (AV) block is not recommended unless they have limited vascular access or a high infection risk; nevertheless, an unexpectedly high number of VVI-LPM implantations have been performed.

View Article and Find Full Text PDF

Background: The optimum cut-off value of premature atrial contraction (PAC) burden (CV-PACb) in 24-h Holter electrocardiography (24-h ECG) for predicting atrial fibrillation (AF) is debatable, with few validation data.

Methods and results: We retrospectively analyzed 61 patients already diagnosed with AF (AD-AF) and 147 patients never diagnosed with AF (ND-AF), aged ≥50 years, free of heart disease, and who had undergone 24-h ECG and transthoracic echocardiography (TTE). Receiver operating characteristic analysis demonstrated that 0.

View Article and Find Full Text PDF