Background And Aim: Elobixibat is a triple mode of action laxative that increases water secretion into the colon, promotes colonic motility, and reestablishes the defecation desire. This study aims to evaluate the effectivity and safety of elobixibat in chronic constipation (CC) patients refractory to conventional laxatives.
Methods: A single-center retrospective observational study was conducted in refractory CC patients diagnosed according to the Rome IV criteria and received elobixibat between April 2018 and June 2022 at Osaka Saiseikai Nakatsu Hospital.
Background/aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting.
View Article and Find Full Text PDFBackground/aims: Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) using oblique-view EUS in patients with a surgically altered anatomy (SAA) of the upper gastrointestinal tract is limited because of difficult scope insertion due to the disturbed anatomy. This study aimed to investigate the efficiency of forward-view (FV)-EUS in performing FNA in patients with a SAA.
Methods: We retrospectively investigated 32 patients with a SAA of the upper gastrointestinal tract who visited Aichi Cancer Center Hospital in Nagoya, Japan, between January 2014 and December 2020.
Background And Objectives: EUS-guided hepaticogastrostomy (EUS-HGS) is in widespread use; however, there are few dedicated devices. The B2 route is technically easier than the B3 route for guidewire insertion, dilation, and stenting but if performed with conventional oblique-viewing (OV) EUS, B2 puncture can cause transesophageal puncture and severe adverse events. The aim of this study was to assess the efficacy of forward-viewing (FV) EUS, which we have developed to improve safety for B2 puncture in EUS-HGS (B2-EUS-HGS).
View Article and Find Full Text PDFBACKGROUND : There are several types of pancreatic mass, so it is important to distinguish between them before treatment. Artificial intelligence (AI) is a mathematical technique that automates learning and recognition of data patterns. This study aimed to investigate the efficacy of our AI model using endoscopic ultrasonography (EUS) images of multiple types of pancreatic mass (pancreatic ductal adenocarcinoma [PDAC], pancreatic adenosquamous carcinoma [PASC], acinar cell carcinoma [ACC], metastatic pancreatic tumor [MPT], neuroendocrine carcinoma [NEC], neuroendocrine tumor [NET], solid pseudopapillary neoplasm [SPN], chronic pancreatitis, and autoimmune pancreatitis [AIP]).
View Article and Find Full Text PDFEndoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) is widely performed not only as an alternative to transpapillary biliary drainage, but also as primary drainage for malignant biliary obstruction. For anatomical reasons, this technique carries an unavoidable risk of mispuncturing intrahepatic vessels. We report a technique for troubleshooting EUS-guided portal vein coiling to prevent bleeding from the intrahepatic portal vein after mispuncture during interventional EUS.
View Article and Find Full Text PDFBackground/aims: The Japan Gastroenterological Endoscopy Society (JGES) has published guidelines for gastroenterological endoscopy in patients undergoing antithrombotic treatment. These guidelines classify endoscopic ultrasound-guided biliary drainage (EUS-BD) as a high-risk procedure. Nevertheless, the bleeding risk of EUS-BD in patients undergoing antithrombotic therapy is uncertain.
View Article and Find Full Text PDFEndoscopic ultrasonography (EUS) is an essential diagnostic tool for various types of pancreatic diseases such as pancreatic tumors and chronic pancreatitis; however, EUS imaging has low specificity for the diagnosis of pancreatic diseases. Artificial intelligence (AI) is a mathematical prediction technique that automates learning and recognizes patterns in data. This review describes the details and principles of AI and deep learning algorithms.
View Article and Find Full Text PDFLow birth weight (LBW) has been known to increase the susceptibility to renal injury in adulthood. A 26-year-old woman developed proteinuria in early pregnancy; she had been born with very LBW. The clinical course was progressive, and an emergency Caesarean section was performed at 36 weeks due to acute kidney injury.
View Article and Find Full Text PDFThe occurrence of preeclampsia before 20 weeks of gestation is rare and usually associated with trophoblastic diseases or antiphospholipid syndrome. Here, we report a case of preeclampsia before 20 weeks of gestation in the absence of the aforementioned disorders. A healthy 30-year-old nulliparous woman presented with new onset of hypertension and proteinuria at 18 weeks of gestation.
View Article and Find Full Text PDF