Although the innovation has come in ECMO field, many problems remain unresolved. One of the main problems is about long-term durability and biocompatibility. Another is the system's size, weight, and its complicated equipment.
View Article and Find Full Text PDFThe purpose of this study was to observe and clarify the interventricular dysscynchrony caused by continuous-flow left ventricular assist device (CF-LVAD) support using the conductance method. During CF-LVAD support, the systolic phase of the left ventricle (LV) becomes shorter than that of the right ventricle (RV). Accordingly, timing of the systole and diastole during the cardiac cycle is not synchronous between the LV and RV.
View Article and Find Full Text PDFWe developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of this study was to assess the postoperative performance, hemocompatibility, and anticoagulative status during an extended period of its use. A VAD system, consisting of a hydrodynamically levitated pump, measuring 64 mm by 131 mm in size and weighing 635 g, was used.
View Article and Find Full Text PDFAortic insufficiency (AI) is an intractable complication during long term left ventricular assist device (LVAD) support. Conventional evaluation of AI depends on ultrasound evaluation, which is mainly a qualitative, not a quantitative method. The pathophysiology of AI during LVAD is shunt formation.
View Article and Find Full Text PDFAortic insufficiency (AI) is a crucial complication during continuous-flow left ventricular assist device (LVAD) support. Our previous clinical study suggested that a larger angle between the outflow graft and the aorta (O-A angle) could cause AI progression. This study examined the effect of the O-A angle on the hemodynamics of AI under LVAD support in an acute animal experimental model.
View Article and Find Full Text PDFTissue-engineered heart valves (TEHVs) are expected to be viable grafts. However, it is unknown whether they transit their histological structure after implantation. We developed a novel autologous TEHV (named stent biovalve) for transcatheter implantation, using in-body tissue engineering based on a tissue encapsulation phenomenon.
View Article and Find Full Text PDFCarney complex(CNC) is a rare genetic syndrome, characterized by spotty pigmentation of the skin, cardiac myxomas and multiple endocrine tumors. We present a case of asymptomatic cardiac myxoma associated with CNC. She was 49 year-old healthy woman whose son was known to have CNC.
View Article and Find Full Text PDFAortic insufficiency (AI) is a worrisome complication under left ventricular assist device (LVAD) support. AI progression causes LVAD-left ventricular (LV) recirculation and can require surgical intervention to the aortic valve. However, the limitations of LVAD support are not well known.
View Article and Find Full Text PDFChemical conjugation between hydrophilic and hydrophobic components is difficult because of their extremely different solubility. Herein, we report a new versatile method with a solid-phase-assisted disulfide ligation to overcome the difficulty of conjugation attributed to solubility. The method involves two steps in a one-pot process: 1) loading of a hydrophobic molecule onto a resin in an organic solvent, and 2) release of the solid-supported hydrophobic molecule as a conjugate with a hydrophilic molecule into an aqueous solvent.
View Article and Find Full Text PDFAbdominal aortic aneurysm (AAA) is known to be rarely accompanied by disseminated intravascular coagulation (DIC). We report a case of AAA with DIC. An 81-year-old man with abdominal pain referred to our hospital.
View Article and Find Full Text PDFDuring cardiac surgery through midline sternotomy, sternum closure metal wires are usually used for. However, metal wires may damage the sternum and cause artifacts on X-ray. Therefore, we use a novel sternum closure technique in which metal wire is replaced by ultra-high molecular weight polyethylene(UHMWP) sutures.
View Article and Find Full Text PDFAlthough several approaches for making antibody-drug conjugates (ADC) have been developed, it has yet to be reported that an antibody binding peptide such as Z33 from protein A is utilized as the pivotal unit to generate the noncovalent-type ADC (NC-ADC). Herein we aim to establish a novel probe for NC-ADC by synthesizing the Z33-conjugated antitumor agent, plinabulin. Due to the different solubility of two components, including hydrophobic plinabulin and hydrophilic Z33, an innovative method with a solid-supported disulfide coupling reagent is required for the synthesis of the target compounds with prominent efficiency (29% isolated yield).
View Article and Find Full Text PDF