Background Conventionally, two-dimensional (2D) fast spin-echo (FSE) sequences have been widely used for clinical cartilage imaging as well as gradient (GRE) sequences. Recently, three-dimensional (3D) volumetric magnetic resonance imaging (MRI) has been introduced with one 3D volumetric scan, and this is replacing slice-by-slice 2D MR scans. Purpose To evaluate the image quality and diagnostic performance of two 3D sequences for abnormalities of knee cartilage: fat-suppressed (FS) FSE-based 3D volume isotropic turbo spin-echo acquisition (VISTA) and GRE-based 3D T1 high-resolution isovolumetric examination (THRIVE).

View Article and Find Full Text PDF

Background: Although many three-dimensional (3D) magnetic resonance imaging (MRI) sequences have been used in the clinical field, there are no studies on fat-suppressed (FS) 3D sequences for the diagnosis of knee abnormalities.

Purpose: To evaluate the usefulness of FS 3D volume isotropic turbo spin echo acquisition (VISTA) imaging for diagnosis of internal structures of knee.

Material And Methods: In 137 patients with 138 knee MRI examinations who had undergone both FS 3D VISTA MRI and two-dimensional (2D) MRI of the knee at 3.

View Article and Find Full Text PDF

Background And Purpose: Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 3T in patients with spinal prostheses.

Methods: Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed.

View Article and Find Full Text PDF

Background: Dual-energy computed tomography (DECT) images may be underutilized for the evaluation of skeletal metastasis. Spectral parametric segmentation of DECT can produce bone-iodine separated images, which have the potential to detect bone metastases.

Purpose: To evaluate the potential of bone-iodine separation in the detection of bone metastasis with spectral parametric segmentation of DECT images which are acquired at clinical follow-up for patients with prior malignancy.

View Article and Find Full Text PDF

Rationale And Objectives: To assess the usefulness of T2*-corrected fat fraction (FF) map from volume-interpolated breathhold examination (VIBE) magnetic resonance (MR) sequence in patients with the rotator cuff pathology.

Materials And Methods: The phantom study was performed to validate the FF maps. Eighty-nine shoulder MR arthrographies were analyzed: (1) divided into three groups namely tendinopathy/normal tendons, partial-thickness tears, and full-thickness tears, and (2) occupation ratio (OR) was measured for muscular atrophy.

View Article and Find Full Text PDF

Objective: To assess the diagnostic value of fat-suppressed (FS) three-dimensional (3D) volume isotropic turbo spin echo acquisition (VISTA) imaging in detecting radial and root tears of the meniscus, including the reader-defined reformatted axial (RDA) plane.

Materials And Methods: Twenty-three patients with arthroscopically confirmed radial or root tears of the meniscus underwent magnetic resonance imaging (MRI) with 2D and FS 3D VISTA sequences. MRIs were reviewed independently by two musculoskeletal radiologists blinded to the arthroscopic findings.

View Article and Find Full Text PDF

Objective: The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined.

Subjects And Methods: From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded.

View Article and Find Full Text PDF

Purpose: The purpose of the study was to assess the usefulness of slice encoding for metal artifact correction (SEMAC) in 3.0-T magnetic resonance (MR) in minimizing metallic artifacts in patients with spinal prostheses.

Materials And Methods: Institutional review board approval and informed consent were obtained for this study.

View Article and Find Full Text PDF

Background: Plain chest radiographs and pulmonary function tests have been used for pulmonary screening for flight duties of aircrews of the Republic of Korea Air Force. However, the screening accuracy of plain chest radiographs is controversial. Chest CT imaging with low-dose protocol (LDCT) improves detection of intra-thoracic abnormalities compared to plain chest radiographs.

View Article and Find Full Text PDF

Introduction: As modern aircraft fly at higher altitudes with rapid velocity, pilots have been put in the environment with a possible increasing risk of brain injury and could sustain cumulative brain damage. However, very few studies have investigated brain lesions using MRI in asymptomatic pilots. We evaluated asymptomatic pilots for the presence of cerebral lesions using MRI.

View Article and Find Full Text PDF

Migraine has been found to be associated with patent foramen ovale. However, in practice, it is difficult to show that microemboli via patent foramen ovale can induce a migraine attack. Our patient showed transient sulcal hyperintensities on fluid-attenuated inversion recovery images during a migraine attack.