Publications by authors named "Daegab Gweon"

Atherosclerotic plaque is a chronic inflammatory disorder involving lipid accumulation within arterial walls. In particular, macrophages mediate plaque progression and rupture. While PPARγ agonist is known to have favorable pleiotropic effects on atherogenesis, its clinical application has been very limited due to undesirable systemic effects.

View Article and Find Full Text PDF

High internal phase emulsions have been widely used as templates for various porous materials, but special strategies are required to form, in particular, particle-covered ones that have been more difficult to obtain. Here, we report a versatile strategy to produce a stable high internal phase Pickering emulsion by exploiting a depletion interaction between an emulsion droplet and a particle using water-soluble polymers as a depletant. This attractive interaction facilitating the adsorption of particles onto the droplet interface and simultaneously suppressing desorption once adsorbed.

View Article and Find Full Text PDF
Article Synopsis
  • Fluorescence lifetime imaging microscopy (FLIM) allows for detailed visualization of biological targets but faces limitations in real-time, high-precision imaging.
  • Researchers developed a high-speed method combining a line-to-pixel referencing technique with the analog mean-delay (AMD) method to enhance photon accumulation and efficiency.
  • This new method achieved a frame rate of 3.73 fps and a pixel rate of 3.91 MHz while maintaining measurement precision under 20 ps, significantly improving real-time imaging capabilities.
View Article and Find Full Text PDF

In this paper, we propose a new in-plane XYθz nano-positioning stage that utilizes piezoelectric actuators and flexure mechanisms. The proposed stage has an aperture and is compact, which facilitates its application in measurement equipment, especially those used for biological specimens. The stage has four piezoelectric actuators and four bridge-type flexure mechanisms, which are used to amplify the small motions produced by the piezoelectric actuators.

View Article and Find Full Text PDF

Macrophages mediate atheroma expansion and disruption, and denote high-risk arterial plaques. Therefore, they are substantially gaining importance as a diagnostic imaging target for the detection of rupture-prone plaques. Here, we developed an injectable near-infrared fluorescence (NIRF) probe by chemically conjugating thiolated glycol chitosan with cholesteryl chloroformate, NIRF dye (cyanine 5.

View Article and Find Full Text PDF

We propose a new structure of confocal imaging system based on a direct-view confocal microscope (DVCM) with an electrically tunable lens (ETL). Since it has no mechanical moving parts to scan both the lateral (x-y) and axial (z) directions, the DVCM with an ETL allows for high-speed 3-dimensional (3-D) imaging. Axial response and signal intensity of the DVCM were analyzed theoretically according to the pinhole characteristics.

View Article and Find Full Text PDF

Aims: Inflammation plays essential role in development of plaque disruption and coronary stent-associated complications. This study aimed to examine whether intracoronary dual-modal optical coherence tomography (OCT)-near-infrared fluorescence (NIRF) structural-molecular imaging with indocyanine green (ICG) can estimate inflammation in swine coronary artery.

Methods And Results: After administration of clinically approved NIRF-enhancing ICG (2.

View Article and Find Full Text PDF

A nonresonant, fiber-optic raster scanning endomicroscope was developed using a quarter-tubular piezoelectric (PZT) actuator. A fiber lever mechanism was utilized to enhance the small actuation range of the tubular PZT actuator and to increase its field-of-view. Finite element method simulation of the endoscopic probe was conducted for various conditions to maximize its scanning range.

View Article and Find Full Text PDF

This paper presents the development of a new compact three-axis compliant stage employing piezoelectric actuators and a new flexure structure. A proposed stage works out-of-plane (Z, θx, θy) direction. The stage consists of 4 amplification flexures mounted piezoelectric actuators.

View Article and Find Full Text PDF

We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system.

View Article and Find Full Text PDF

Chromatic confocal microscopy (CCM) is a promising technology that enables high-speed three-dimensional surface profiling without mechanical depth scanning. However, the spectrometer, which measures depth information encoded by axial color, limits the speed of three-dimensional imaging. We present a novel method for chromatic confocal microscopy with transmittance detection.

View Article and Find Full Text PDF

We developed a multimodal microscopy based on an optical scanning system in order to obtain diverse optical information of the same area of a sample. Multimodal imaging researches have mostly depended on a commercial microscope platform, easy to use but restrictive to extend imaging modalities. In this work, the beam scanning optics, especially including a relay lens, was customized to transfer broadband (400-1000 nm) lights to a sample without any optical error or loss.

View Article and Find Full Text PDF

This paper describes the design, modeling, optimization, and validation of an active vibration isolation system using a voice coil motor. The active vibration isolating method was constructed with a passive isolator and an active isolator. A spring was used for passive isolating; an actuator was used for active isolating.

View Article and Find Full Text PDF

An integrated allele-specific polymerase chain reaction (AS PCR) and microarray chip has been developed for multiplex single nucleotide polymorphism (SNP) typing on a portable genetic analyzer instrumentation. We applied the integrated PCR-microarray system for on-site Hanwoo (Korean indigenous beef cattle) identification. Eleven sets of primers were designed, among which ten sets of primers targeted ten SNP loci to discriminate Hanwoo from the imported beef cattle and one primer set was used as a positive PCR control.

View Article and Find Full Text PDF

A simple structure of spectral fluorescence lifetime imaging microscope (SLIM) is designed with the use of tunable bandpass filter, a kind of Fabry-perot filter that transmission wavelength is varying according to incident angle of light. Feasibility tests of this angle-tuned bandpass filter (ATBF) are performed and it shows high transmission and constant spectral bandwidth (20 nm) with respect to angle of incidence. Furthermore, using two ATBFs in series, spectral bandwidth can be adjustable down to 4 nm.

View Article and Find Full Text PDF

In this study, we describe the development of a novel, compact, and long range in-plane XYθ(z) nano-positioning stage with piezoelectric actuator and flexure mechanism. The stage is composed of an X-directional motion part and a Y, θ(z)-directional motion part, which are linked serially. The stage consists of a bridge-type amplifying mechanism for the amplification of deformation of the piezoelectric actuator, a double compound guide mechanism for performing only desired motion, and a circular hinge mechanism that permits rotational motion in the Y and θ(z)-stages.

View Article and Find Full Text PDF

Flexure mechanisms have been widely used for nanometer positioning systems. This article presents a novel conceptual design of an ultra-precision 3-degrees of freedom (XYθ(Z)) positioning system with nanometer precision. The main purpose of this novel stage design is for the application of measurement equipment, in particular biological specimens.

View Article and Find Full Text PDF

Spectral (or multi-color) microscopy has the ability to detect the fluorescent light of biological specimens with a broad range of wavelengths. Currently, the acousto-optic tunable filter (AOTF) is widely used in spectral microscopy as a substitute for a multiple-dichroic mirror to divide excitation and emission signals while maintaining sufficient light efficiency. In addition, systems which utilize an AOTF have a very fast switching speed and high resolution for wavelength selection.

View Article and Find Full Text PDF

An integrated allele-specific (AS) polymerase chain reaction (PCR) and capillary electrophoresis (CE) microdevice has been developed for multiplex single nucleotide polymorphism (SNP) genotyping on a portable instrumentation, which was applied for on-site identification of HANWOO (Korean indigenous beef cattle). Twelve sets of primers were designed for targeting beef cattle's eleven SNP loci for HANWOO verification and one primer set for a positive PCR control, and the success rate for identification of HANWOO was demonstrated statistically. The AS PCR and CE separation for multiplex SNP typing was carried out on a glass-based microchip consisting of four layers: a microchannel plate for microfluidic control, a Pt-electrode plate for a resistance temperature detector (RTD), a poly(dimethylsiloxane) (PDMS) membrane and a manifold glass for microvalve function.

View Article and Find Full Text PDF

This paper details the development of a novel flexure jointed precision parallel nano-positioning system in combination with piezo-electric stepping motor for the application of precise optics alignment. The characteristics of the developed system are evaluated in this paper by the simulation and experiments. Based on the precision piezo-electric stepping motor and flexure joints, a high precision motion is obtained.

View Article and Find Full Text PDF

We describe a polarization sensitive spectral domain optical coherence tomography technique based on a single camera spectrometer that includes a multiplexed custom grating, camera lenses, and a high-speed three-line CCD camera. Two orthogonally polarized beams could be separately taken by two lines of the camera as a result of vertically different incident angles. The system could provide the imaging capabilities of a full camera speed and increased measurable depth.

View Article and Find Full Text PDF

In this research, chromatic confocal microscopy with transverse point beam scanning is constructed for three-dimensional surface measurement without longitudinal mechanical translation. In beam scanning chromatic confocal microscopy, the wavelength-to-depth relation and the lateral field of view should be determined considering the beam scanning angle. With the experimental results from a sample structure, the three-dimensional profile is reconstructed by relating the wavelength and scanning angle to the axial and the lateral coordinates.

View Article and Find Full Text PDF

Next-generation lithography requires a high precision stage, which is compatible with a high vacuum condition. A magnetic levitation stage with six degrees-of-freedom is considered state-of-the-art technology for a high vacuum condition. The noncontact characteristic of magnetic levitation enables high precision positioning as well as no particle generation.

View Article and Find Full Text PDF

This paper describes the design and control of a nanoprecision XY Theta scanner consisting of voice coil motors and air bearing guides. The proposed scanner can be installed on a conventional XY stage with long strokes to improve the positioning accuracy and settling performance. Major design considerations in developing a high precision scanner are sensor accuracy, actuator properties, structural stability, guide friction, and thermal expansion.

View Article and Find Full Text PDF

In this article, a linear piezoelectric stepping positioner developed by Kang et al. [Rev. Sci.

View Article and Find Full Text PDF