Objective: Toward the ultimate goal of robust cuff-less blood pressure (BP) tracking with wrist wearables against postural changes, the goal of this work was to investigate posture-dependent variability in pulse transit time (PTT) measured with ballistocardiogram (BCG) and photoplethysmogram (PPG) signal pair at the wrist.
Methods: BCG and PPG signals were acquired from 25 subjects under the combination of 3 body (standing, sitting, and supine) and 3 arm (vertical in head-to-foot direction, placed on the chest, and holding a shoulder) postures. PTT was computed as the time interval between the BCG J wave and the PPG foot, and the impact of the 9 postures on PTT was analyzed by invoking an array of possible physical mechanisms.
Vitamin D plays pivotal role in bone mineral homeostasis. But the association of vitamin D with muscle mass remains obscure, especially among young adults. Therefore, we assessed the association between muscle mass and 25-hydroxyvitamin D (25[OH]D) in South Korean adults using data from the 2009-2010 Korean National Health and Nutrition Examination Survey (KNHANES).
View Article and Find Full Text PDFObjective: Toward the ultimate goal of cuff-less blood pressure (BP) trend tracking via pulse transit time (PTT) using wearable ballistocardiogram (BCG) signals, we present a unified approach to the gating of wearable BCG and the localization of wearable BCG waves.
Methods: We present a unified approach to localize wearable BCG waves suited to various gating and localization reference signals. Our approach gates individual wearable BCG beats and identifies candidate waves in each wearable BCG beat using a fiducial point in a reference signal, and exploits a pre-specified probability distribution of the time interval between the BCG wave and the fiducial point in the reference signal to accurately localize the wave in each wearable BCG beat.
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions.
View Article and Find Full Text PDFBy virtue of its direct association with the cardiovascular (CV) functions and compatibility to unobtrusive measurement during daily activities, the limb ballistocardiogram (BCG) is receiving an increasing interest as a viable means for ultra-convenient CV health and disease monitoring. However, limited insights on its physical implications have hampered disciplined interpretation of the BCG and systematic development of the BCG-based approaches for CV health monitoring. In this study, a mathematical model that can predict the limb BCG in responses to the arterial blood pressure (BP) waves in the aorta was developed and experimentally validated.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
Objective: To investigate the association between a limb ballistocardiogram (BCG) and blood pressure (BP) based on data mining.
Approach: During four BP-perturbing interventions, the BCG and reference BP were measured from 23 young, healthy volunteers using a custom-manufactured wristband equipped with a MEMS accelerometer and a commercial continuous BP measurement device. Both timing and amplitude features in the wrist BCG waveform were extracted, and significant features predictive of diastolic (DP) and systolic (SP) BP were selected using stepwise linear regression analysis.
Annu Int Conf IEEE Eng Med Biol Soc
July 2017
The purpose of this study was to design a modified D-max method to determine heart rate at a ventilatory threshold (HRVT) and to investigate whether this method would be valid during incremental exercise tests. The HRVT was estimated from a new parameter defined as HR at the maximal difference point between linearly- and quadratically approximated HR trends (modified D-max method). HR and ventilatory gas data for 105 subjects (53 males and 52 females; 38.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
This preliminary study investigates feasibility of a running speed based heart rate (HR) prediction. It is basically motivated from the assumption that there is a significant relationship between HR and the running speed. In order to verify the assumption, HR and running speed data from 217 subjects of varying aerobic capabilities were simultaneously collected during an incremental treadmill exercise.
View Article and Find Full Text PDFIn this study, we developed a novel heart rate (HR) monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW) into electrical current, and the circuit module enhances the EPW and suppresses noise.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
January 2015
In this paper, we propose a novel method for enhancing pulse contour analysis-based arterial stiffness estimation using a simple and low-complexity photoplethysmographic parameter (P2Ocd). The method first eliminates baseline wanders in the digital volume pulse (DVP) by applying a simple morphological filter. The filtered DVP signal is then transformed into a slope sum function signal to simplify the pulse peak detection process by enhancing the upslope of the DVP signal while suppressing its downslope.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
January 2016
In this paper, we propose a new probabilistic approach to pulse transit time (PTT) estimation using a Gaussian distribution model. It is motivated basically by the hypothesis that PTTs normalized by RR intervals follow the Gaussian distribution. To verify the hypothesis, we demonstrate the effects of arterial compliance on the normalized PTTs using the Moens-Korteweg equation.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
October 2014
This paper presents a robust method for pulse peak determination in a digital volume pulse (DVP) waveform with a wandering baseline. A proposed new method uses a modified morphological filter (MMF) to eliminate a wandering baseline signal of the DVP signal with minimum distortion and a slope sum function (SSF) with an adaptive thresholding scheme to detect pulse peaks from the baseline-removed DVP signal. Further in order to cope with over-detected and missed pulse peaks, knowledge based rules are applied as a postprocessor.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
August 2012
We have developed a knowledge based approach for arterial stiffness estimation. The proposed new approach reliably estimates arterial stiffness based on the analysis of age and heart rate normalized reflected wave arrival time. The proposed new approach reduces cost, space, technical expertise, specialized equipment, complexity, and increases the usability compared to recently researched noninvasive arterial stiffness estimators.
View Article and Find Full Text PDFMental activity promotion system is presented that analyzes, quantifies, trains and prescribes based on analysis of logical, memorizing, concentrative, decisive, in conditions where time and space is involved, possibility of dementia, and on evaluation of lifestyle of subjects. Special consideration has been made to make the system motivational, persuasive, attractive and fun to use. The system has been successfully deployed in Bitgeoul Senior health town, Gwangju, South Korea.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
March 2011
This paper presents real-time signal processing algorithm for detection of onsets and peaks in Photoplethysmogram (PPG) waveform. Algorithm relies on the analysis of amplitude, slope and inter-beat intervals. The presented algorithm consists of four stages for characterizing PPG waveform.
View Article and Find Full Text PDF