Publications by authors named "DJ Wagenaar"

Despite its high sensitivity, the variable specificity of magnetic resonance imaging (MRI) in breast cancer diagnosis can lead to unnecessary biopsies and over-treatment. Scintimammography (SMM) could potentially supplement MRI to improve the diagnostic specificity. The synergistic combination of MRI and SMM (MRSMM) could result in both high sensitivity from MRI and high specificity from SMM.

View Article and Find Full Text PDF

We describe an MR-compatible SPECT camera for small animals. The SPECT camera system can be inserted into the bore of a state-of-the-art MRI system and allows researchers to acquire tomographic images from a mouse in-vivo with the MRI and the SPECT acquiring simultaneously. The SPECT system provides functional information, while MRI provides anatomical information.

View Article and Find Full Text PDF

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies.

View Article and Find Full Text PDF

The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts.

View Article and Find Full Text PDF

In this study, we investigated the in vivo application of an integrated small-animal magnetic resonance (MR) and gamma-ray imaging system that consists of a semiconductor-based radiation detector, a parallel-hole collimator, and a specialized radiofrequency coil. Gadodiamide and (99m)Tc sestimibi agents were injected simultaneously into a mouse, and simultaneous dynamic contrast-enhanced MR and scintigraphic images of the kidneys were acquired. The time curves of both the MR signal intensity and radioactivity indicate a rapid uptake of the agents followed by a more gradual excretion, consistent with the previously reported literature.

View Article and Find Full Text PDF

In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system.

View Article and Find Full Text PDF

Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system.

View Article and Find Full Text PDF

Multi-modality combinations of SPECT/CT and PET/CT have proven to be highly successful in the clinic and small animal SPECT/CT and PET/CT are becoming the norm in the research and drug development setting. However, the use of ionizing radiation from a high-resolution CT scanner is undesirable in any setting and particularly in small animal imaging (SAI), in laboratory experiments where it can result in radiation doses of sufficient magnitude that the experimental results can be influenced by the organism's response to radiation. The alternative use of magnetic resonance (MR) would offer a high-resolution, non-ionizing method for anatomical imaging of laboratory animals.

View Article and Find Full Text PDF

Unlabelled: The Internet and particularly the World-Wide-Web is becoming a useful tool for the nuclear medicine community.

Methods: The Computer and Instrumentation Council of the Society of Nuclear Medicine convened an Internet Focus group to discuss collaboration using the Internet. The prototype application considered was development of case-based teaching files using the World-Wide-Web.

View Article and Find Full Text PDF

The principle of the kinestatic charge detector (KCD) for digital radiography depends on the synchronization of the scan velocity of a parallel plate drift chamber with the cation drift velocity. Compared with line-beam scanners, this motion-compensated imaging technique makes better use of the x-ray tube output. A Frisch grid traditionally has been used within the KCD to minimize unwanted signal contributions from both cations and negative charge carriers during irradiation.

View Article and Find Full Text PDF

The engineering aspects of a nine-channel digital radiographic system developed for bioimaging research, based on high gas pressure ionography and kinestatic principles, are presented. The research imaging system uses a pulsed x-ray beam which allows one to study simultaneously the ionic signal characteristics at 10 different ionization sites along the drift axis. This research imaging detector system allows one to investigate methods to improve the detection and image quality parameters as part of the development of a large scale prototype medical imaging system.

View Article and Find Full Text PDF

Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and contrast.

View Article and Find Full Text PDF

The broadening of the line spread function (LSF) in the drift direction with increasing drift distance in the kinestatic charge detector is substantially reduced when small amounts (less than 1%) of trimethylamine [(CH3)3 N] are added to the x-ray detection medium (krypton or xenon). The LSF of a mixture of Kr and 0.01% trimethylamine (TMA) was measured as a function of distance at 15, 25, and 35 atm absolute pressure.

View Article and Find Full Text PDF

The effects of space charge in a kinestatic charge detector (KCD) were examined using computer solutions to Poisson's equation. The KCD is a strip-beam parallel-plate drift chamber used for digital radiography. It was assumed that there is negligible electron attachment, i.

View Article and Find Full Text PDF