Publications by authors named "D Zverev"

The excellent versatility of 5-axis computer numerical control (CNC) micromilling has led to its application for prototyping NMR microcoils tailored to mass-limited samples (reducing development time and cost). However, vibrations during 5-axis milling can hinder the creation of complex 3D volume microcoils (i.e.

View Article and Find Full Text PDF

Purpose: In a cohort, observational prospective trial, we assessed the long-term dynamics of sleep-disordered breathing in patients with resistant hypertension after renal denervation and their association with blood pressure change at remote follow-up.

Materials And Methods: Twenty-eight patients with stable hypertension who were recruited for endovascular radiofrequency renal denervation in 2012-2019 and had valid both baseline and follow-up sleep study, were included in the analysis. All patients underwent physical examination, anthropometry, office and ambulatory blood pressure measurements, blood and urine tests, kidney visualization, and full polysomnography before and within 12-36 months after renal denervation.

View Article and Find Full Text PDF

In environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR).

View Article and Find Full Text PDF

Positive allosteric modulators (PAMs) of AMPA receptors represent attractive candidates for the development of drugs for the treatment of cognitive and neurodegenerative disorders. Dimeric molecules have been reported to have an especially potent modulating effect, due to the U-shaped form of the AMPA receptor's allosteric binding site. In the present work, novel bis(pyrimidines) were studied as AMPA receptor modulators.

View Article and Find Full Text PDF

A coherent X-ray beam expander based on a multilens interferometer is proposed in this paper. The multilens interferometer allows efficient generation of a highly diverging coherent beam up to several milliradians in the hard X-ray energy range. The optical properties of the interferometer were experimentally demonstrated at the ESRF ID13 undulator beamline (Grenoble, France), using 12.

View Article and Find Full Text PDF