Publications by authors named "D Tamez"

Purpose: CoRISMA MCS Systems Inc (Hamden CT) is developing an innovative mechanical circulatory support system (CMCS) as a durable therapeutic option for heart failure (HF) patients. The CMCS system is comprised of an axial flow pump, non-contacting hydrodynamic bearings, and integrated DC motor designed to be fully implantable in a left atrial (LA) to aortic (Ao) configuration; this unloading strategy may be particularly beneficial for HF patients with preserved ejection fraction (HFpEF). The small (5.

View Article and Find Full Text PDF

Background: Histology of thrombosis events in left ventricular assist devices (LVADs) may point to differences between the etiology of either ingested or de novo thrombus formation within LVADs. Materials ingested by the pump would have features suggestive of lifting and folding, whereas thrombi formed de novo would have uniform, parallel layers. This study tested this hypothesis in a cohort of explanted HeartWare Ventricular assist devices (HVADs) (Medtronic, Miami Lakes, Florida).

View Article and Find Full Text PDF

Liver transplant centers in the United States retain great autonomy in determining eligibility criteria for a liver transplant. This study aims to define the availability and content of liver transplant centers' publicly available Internet policies regarding eligibility criteria for liver transplant. Three trained undergraduate students performed a structured pilot-tested assessment of official websites of the United Network for Organ Sharing-registered liver transplant centers.

View Article and Find Full Text PDF

Unlabelled: Interactions between the life-sustaining ventricular assist devices and diagnostic therapies must be carefully considered to decrease the risk of inaccurate diagnostic imaging or pump failure.

Methods: The MVAD(®) pump, currently under investigational use, was tested for interaction with radiotracers in an in vitro flow-loop study. The radiotracers (18)F-sodium fluoride and (18)F-FDG were injected into a closed loop to determine the feasibility of direct imaging of the MVAD(®) pump in a PET scanner.

View Article and Find Full Text PDF

New left ventricular assist devices (LVADs) offer both important advantages and potential hazards. VAD development requires better and expeditious ways to identify these advantages and hazards. We validated in an isolated working heart the hemodynamic performance of an intraventricular LVAD and investigated how its outflow cannula interacted with the aortic valve.

View Article and Find Full Text PDF