Publications by authors named "D S Kravchenko"

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Objectives: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2S and DWIS) and with BG (T2BG and DWIBG).

Materials And Methods: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions.

View Article and Find Full Text PDF

Background: This study aimed to determine whether artificial intelligence (AI)-based automated assessment of left atrioventricular coupling index (LACI) can provide incremental value above other traditional risk factors for predicting mortality among patients with severe aortic stenosis (AS) undergoing coronary CT angiography (CCTA) before transcatheter aortic valve replacement (TAVR).

Methods: This retrospective study evaluated patients with severe AS who underwent CCTA examination before TAVR between September 2014 and December 2020. An AI-prototype software fully automatically calculated left atrial and left ventricular end-diastolic volumes and LACI was defined by the ratio between them.

View Article and Find Full Text PDF

Rationale And Objectives: The purpose of this study was to explore intra-individual differences in pericoronary adipose tissue (PCAT) fat attenuation index (FAI) between photon-counting detector (PCD)- and energy-integrating detector (EID)-CT.

Material And Methods: Patients were prospectively enrolled for a PCD-CT research scan within 30 days of EID-CT. Both acquisitions were reconstructed using a Qr36 kernel at 0.

View Article and Find Full Text PDF

Objectives: To implement and evaluate a super-fast and high-quality biparametric MRI (bpMRI) protocol for prostate imaging acquired at a new ultra-high gradient 3.0-T MRI system.

Methods: Participants with clinically suspected prostate cancer prospectively underwent a multiparametric MRI (mpMRI) on a new 3.

View Article and Find Full Text PDF