Publications by authors named "D P Naughton"

Objective: To assess the reliability of implant stability measurements recorded with the Periotest device and to investigate the differences in values when these measurements were taken on implant retained crowns and healing abutments.

Materials And Methods: Fifty-six implants in eight synthetic bone blocks were used to carry out implant stability measurements using the Periotest device by two different operators. Each block constituted an example of bone of density D1, D2, D3, or D4, and two blocks of each density were used.

View Article and Find Full Text PDF

Cervical carcinogenesis is the leading cause of cancer-related deaths in women, and the role of high-risk human papillomavirus (HR-HPV) as a possible risk factor in the development of this cancer is well recognized. Despite the availability of multi-therapeutic approaches, there is still major concern regarding the prevention of metastatic dissemination and excessive tissue injuries. Therefore, it is imperative to develop a safer and more efficient treatment modality.

View Article and Find Full Text PDF

Lipid oxidations products (LOPs) are reactive mutagenic and carcinogenic species known to be generated in thermally stressed culinary oils. Mapping the evolution of LOPs in culinary oils exposed to standard frying practices - both continuous and discontinuous thermo-oxidation - at 180 °C is vital to our understanding of these processes, and to the development of scientific solutions for their effective suppression. Modifications in the chemical compositions of the thermo-oxidised oils were analysed using a high-resolution proton nuclear magnetic resonance (H NMR) technique.

View Article and Find Full Text PDF

Objectives: To evaluate the efficacy of a novel mount with torque control for tightening of Osstell® transducers and to determine the reliability of recorded ISQ measurements from implants placed in various bone densities. MATERIAL AND METHODS: Fifty-six implants, comprising seven different implant types, were placed in eight polyurethane blocks representing D1, D2, D3, and D4 bone densities. Resonance frequency analysis (RFA) transducers were attached to each implant in four different ways: (a) hand tightening, (b) hand tightening with a SmartPeg Mount™, (c) hand tightening using the novel mount with torque control (SafeMount) and (d) tightening to 6 Ncm with a calibrated torque device.

View Article and Find Full Text PDF

Background: In laboratory-based neuroanatomical studies, surgical freedom, the most important metric of instrument maneuverability, has been based on Heron's formula. Inaccuracies and limitations hinder this study design's applicability. A new methodology, volume of surgical freedom (VSF), may produce a more realistic qualitative and quantitative representation of a surgical corridor.

View Article and Find Full Text PDF