Objective: To evaluate the safety, feasibility, and tissue response of a novel device for the treatment of lower urinary tract symptoms secondary to benign prostatic hyperplasia, using the first-generation Urocross Expander System (Mercury Expander System).

Methods: The implant was deployed and retrieved using flexible cystoscope in 8 adult male canines, separated into three study arms by retrieval date (1-, 6-, and 12- months post-deployment). Cystoscopy and urethrograms verified implant position/diameter; bladder neck and external sphincter function/changes; prostatic tissue response; and implant condition.

View Article and Find Full Text PDF

Background: MIV-711 is a highly potent and selective cathepsin K inhibitor. The current article summarizes the therapeutic effects of MIV-711 on joint pathology in rabbits subjected to anterior cruciate ligament transection (ACLT), and the prophylactic effects on joint pathology in dogs subjected to partial medial meniscectomy, two surgical models of osteoarthritis (OA).

Methods: Starting 1 week after surgery, rabbits were dosed daily via oral gavage with either MIV-711 or vehicle (n = 7/group) for 7 weeks.

View Article and Find Full Text PDF

Purpose: Surface microtopography offers a promising approach for infection control. The goal of this study was to provide evidence that micropatterned surfaces significantly reduce the potential risk of medical device-associated infections.

Methodology: Micropatterned and smooth surfaces were challenged in vitro against the colonization and transference of two representative bacterial pathogens - Staphylococcus aureus and Pseudomonas aeruginosa.

View Article and Find Full Text PDF

Introduction: Radiofrequency ablation (RFA) is used for the local treatment of liver cancer. RFA is effective for small (<3 cm) tumors, but for tumors > 3 cm, there is a tendency to leave viable tumor cells in the margins or clefts of overlapping ablation zones. This increases the possibility of incomplete ablation or local recurrence.

View Article and Find Full Text PDF

Objective: The objective of this study was to compare the biomechanical strength of two barbed suture devices: V-Loc™ 180 Wound Closure Device and Quill™ PDO Knotless Tissue-Closure Device following primary cosmetic skin closures in a porcine dermal model.

Method: This prospective randomized, controlled in vivo trial compared size 3/0 V-Loc™ 180 device to size 2/0 Quill™ PDO device. Both products were tested for dermal closure in adult porcine models and evaluated at five timepoints.