Objectives: To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices.
Methods: This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational-age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer.