Publications by authors named "D G Markhorst"

Article Synopsis
  • Noninvasive respiratory support via face masks is crucial for treating respiratory failure in adults and children, yet poor mask fit often leads to discomfort and ineffective treatment.
  • Customized, personalized masks tailored to individual facial dimensions have emerged as a solution over the past decade, with a review examining 23 studies highlighting advancements and ongoing gaps in knowledge.
  • While most studies show positive results regarding the comfort and performance of these personalized masks, further research is required on materials, design, and cost-effectiveness to support broader clinical implementation.
View Article and Find Full Text PDF

Background: Lung volume optimization maneuvers (LVOM) are necessary to make physiologic use of high-frequency oscillatory ventilation (HFOV), but lung behavior during such maneuvers has not been studied to determine lung volume changes after initiation of HFOV, to quantify recruitment versus derecruitment during the LVOM and to calculate the time to stabilization after a pressure change.

Methods: We performed a secondary analysis of prospectively collected data in subjects < 18 years on HFOV. Uncalibrated respiratory inductance plethysmography (RIP) tracings were used to quantify lung recruitment and derecruitment during the LVOM inflation and deflation.

View Article and Find Full Text PDF

Background: Obtaining a properly fitting non-invasive ventilation (NIV) mask to treat acute respiratory failure is a major challenge, especially in young children and patients with craniofacial abnormalities. Personalization of NIV masks holds promise to improve pediatric NIV efficiency. As current customization methods are relatively time consuming, this study aimed to test the air leak and surface pressure performance of personalized oronasal face masks using 3D printed soft materials.

View Article and Find Full Text PDF

In this case report, we describe two repeated transcutaneous electromyography of the diaphragm (dEMG) measurements in an infant with suspected paresis of the right hemidiaphragm after cardiac surgery. The first measurement, performed at the time of diagnosis, showed a lower electrical activity of the right side of the diaphragm in comparison with the left side. The second measurement, performed after a period of expectative management, showed that electrical activity of the affected side had increased and was similar to the activity of the left diaphragm.

View Article and Find Full Text PDF