Publications by authors named "D F Schaling"

The double magnetic induction (DMI) method has successfully been used to record head-unrestrained gaze shifts in human subjects (Bremen et al., J Neurosci Methods 160:75-84, 2007a, J Neurophysiol, 98:3759-3769, 2007b). This method employs a small golden ring placed on the eye that, when positioned within oscillating magnetic fields, induces orientation-dependent voltages in a pickup coil in front of the eye.

View Article and Find Full Text PDF

The value of immunoscintigraphy in the diagnosis of choroidal melanoma is discussed and compared with other diagnostic procedures with isotopes and diagnostic modalities like fluorescein angiography, standardized ultrasonography and magnetic resonance imaging. Consecutive studies with immunoscintigraphy in choroidal melanoma show a sensitivity of 41 to 49%, which can be improved by use of single photon emission computerized tomography (SPECT). Another technique which has improved the results of radio-immunoscintigraphy is the use of a three-step labelling procedure with biotinylated anti-tumor antibodies and avidin.

View Article and Find Full Text PDF

A prospective clinical study to assess the value of immunoscintigraphy with a monoclonal antibody (MoAb) against high molecular weight melanoma associated antigen (225.28S) was performed in 43 patients with choroidal melanoma; in six patients with a lesion suspected of being choroidal melanoma, and in seven patients with a benign lesion simulating a choroidal melanoma. The results of immunoscintigraphy in choroidal melanoma were compared with results of conventional diagnostic modalities like ultrasonography and fluorescein angiography.

View Article and Find Full Text PDF

In view of the importance of clinical applications of ruthenium-106 beta-ray sources for the treatment of choroidal melanoma, experimental, and theoretical approaches are presented for the dosimetry of such sources. The absolute dose and percentage depth dose of ruthenium applicators have been measured with an extrapolation ionization chamber. For a special flat applicator the absolute dose could be measured with an accuracy of +/- 5%, which is determined by the collection efficiency of the extrapolation chamber.

View Article and Find Full Text PDF

A summary is given of data on the clinical experience with the anti-melanoma antibody 225.28S in ophthalmology and the tissue expression of the high molecular weight-melanoma associated antigen in choroidal melanoma. Results are discussed in relation to other detection methods for ocular melanoma currently employed by the ophthalmologist.

View Article and Find Full Text PDF