Background And Purpose: Vasospasm is a common iatrogenic event during mechanical thrombectomy (MT). In such circumstances, intra-arterial nimodipine administration is occasionally considered. However, its use in the treatment of iatrogenic vasospasm during MT has been poorly studied.
View Article and Find Full Text PDFBackground: Although flow diverters (FDs) have benefited from several technical improvements, recently concerns have arisen regarding the braid stability after implantation. Thus, we investigated frequency, predictive factors, and clinical impact of the phenomenon of FD braid deformation (FDBD).
Methods: Consecutive intracranial aneurysms (IAs) treated with various FDs, between January 2018 and July 2023, were reviewed to identify FDBD (defined as the deformation of a FD without any external force applied to it).
Background: The Contour Embolization Device (CED) is typically assessed using coiling angiographic outcomes. However, these scales do not address device-specific problematics. We evaluated the usability of the Bicêtre occlusion scale (BOS) with the CED.
View Article and Find Full Text PDFLife (Basel)
March 2023
3D rotational angiography is now increasingly used in routine neuroendovascular procedures--in particular, for situations where the analysis of two overlayed sets of volume imaging proves useful for planning the treatment strategy or for confirming the optimal apposition of the intravascular devices used. The aim of this study is to identify and describe the decision algorithm for which the overlay function of 3D rotational angiography volumes, high-resolution contrast-enhanced flat panel detector CT adapted for intravascular devices (VasoCT/DynaCT), non-enhanced flat detector C-arm volume acquisition functionality integrated with the angiography equipment (XperCT/DynaCT), and isovolumetric MRI volumes were all used in treatments performed in a series of 29 patients. Two superposed 3DRA volumes were used in the treatment aneurysms located at the junction of two vascular territories and for arteriovenous malformations with compartments fed from different vascular territories.
View Article and Find Full Text PDFBackground And Purpose: Some Woven EndoBridge devices present a persistent intradevice opacification at imaging follow-up, described as the Bicêtre Occlusion Scale Score 1 (BOSS 1) phenomenon. The clinical implications remain unknown. We aimed here to analyze the factors influencing this occurrence and to precisely describe the evolution of BOSS 1 with time using conebeam CT.
View Article and Find Full Text PDF