Rates of acute care use, including hospital admission and readmission, are high for people who misuse substances. Hospitalization provides a valuable opportunity for intervention, but addiction treatment is often not addressed in the inpatient setting. Addiction consult services are a novel intervention intended to change hospital practices.

View Article and Find Full Text PDF

Purpose: Trigeminal neuralgia (TN) can be treated on the CyberKnife system using two different treatment delivery paths: the general-purpose full path corrects small rotations, while the dedicated trigeminal path improves dose fall-off but does not allow rotational corrections. The study evaluates the impact of uncorrected rotations on brainstem dose and the length of CN5 (denoted as L) covered by the prescription dose.

Methods And Materials: A proposed model estimates the delivered dose considering translational and rotational delivery errors for TN treatments on the CyberKnife system.

View Article and Find Full Text PDF

Purpose: To investigate the feasibility of a 4D Monte Carlo based dose reconstruction method to study the dosimetric impact of respiratory motion using surface motion measurements for patients undergoing VMAT treatments for Non-Small Cell Lung Cancer.

Methods: The 4Ddefdosxyznrc/EGSnrc algorithm was used to reconstruct VMAT doses delivered to the patients using machine log files and respiratory traces measured with the RADPOS 4D dosimetry system. The RADPOS sensor was adhered to the patient's abdomen prior to each treatment fraction and its position was used as a surrogate for tumour motion.

View Article and Find Full Text PDF

Background: An analytical tool is empirically validated and used to assess the delivered dose to liver lesions accounting for different types of errors in robotic radiosurgery treatment.

Material And Methods: A tool is proposed to estimate the target doses taking into account the translation, rotation, and deformation of a target. Translational errors are modeled as a spatial convolution of the planned dose with a probability distribution function derived from treatment data.

View Article and Find Full Text PDF

Introduction: Discrimination toward sex and gender minority anesthesiologists and anesthesia trainees exists. Potential reasons for this discrimination are unclear and incompletely characterized. This study sought to better understand what discrimination looks like for sex and gender minorities in anesthesiology and the culture within anesthesiology that allows this discrimination to occur.

View Article and Find Full Text PDF

Purpose: Models of daytime and nighttime on-call responsibilities for residents vary across internal medicine training programs, but there are few data regarding residents' perceptions of their on-call experiences. The authors sought to understand what residents perceive as the benefits and detriments of 24-hour, in-house call, a perspective instrumental to informing change.

Method: The authors conducted in-depth individual interviews and focus groups between December 2018 and March 2019 with 17 internal medicine residents from postgraduate years 1, 2, and 3 at the University of Toronto about their on-call experiences.

View Article and Find Full Text PDF

Purpose: An adaptive planning target volume (PTV) margin strategy incorporating a volumetric tracking error assessment after each fraction is proposed for robotic stereotactic body radiation therapy (SBRT) liver treatments.

Methods And Materials: A supervised machine learning algorithm employing retrospective data, which emulates a dry-run session prior to planning, is used to investigate if motion tracking errors are <2 mm, and consequently, planning target volume (PTV) margins can be reduced. A fraction of data collected during the beginning of a treatment course emulates a dry-run session (mock) before planning.

View Article and Find Full Text PDF

Purpose: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an elastic tumor was modified to enable programming of arbitrary motion profiles. 4D simulations of the dose delivered to the phantom were compared with the measurements.

View Article and Find Full Text PDF

Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescence dosimetry in a clinical setting. This includes: (a) to review the variety of TLD/OSLD materials available, including features and limitations of each; (b) to outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used; (c) to develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice; and (d) to develop guidelines for special medically relevant uses of TLDs/OSLDs such as mixed photon/neutron field dosimetry, particle beam dosimetry, and skin dosimetry.

View Article and Find Full Text PDF

Purpose: Permanent implant prostate brachytherapy plays an important role in prostate cancer treatment, but dose evaluations typically follow the water-based TG-43 formalism, ignoring patient anatomy and interseed attenuation. The purpose of this study is to investigate advanced TG-186 model-based dose calculations via retrospective dosimetric and radiobiological analysis for a new patient cohort.

Methods And Materials: A cohort of 155 patients treated with permanent implant prostate brachytherapy from The Ottawa Hospital Cancer Centre is considered.

View Article and Find Full Text PDF

To assess the geometrical accuracy and estimate adequate PTV margins for liver treatments using the Synchrony respiratory tracking system. : Treatment log files are analyzed for 72 liver patients to assess tracking accuracy. The tracking error is calculated as the quadratic sum of the correlation, the predictor and the beam positioning errors.

View Article and Find Full Text PDF

Purpose: To explain the deviation observed between measured and Monaco calculated dose profiles for a small field (i.e., alternating open-closed MLC pattern).

View Article and Find Full Text PDF

Purpose: The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKnife treatments is assessed quantitatively for different phantom types and breathing motions, which increase in complexity to more closely resemble clinical situations.

View Article and Find Full Text PDF

Purpose: To verify the accuracy of 4D Monte Carlo (MC) simulations, using the 4DdefDOSXYZnrc user code, in a deforming anatomy. We developed a tissue-equivalent and reproducible deformable lung phantom and evaluated 4D simulations of delivered dose to the phantom by comparing calculations against measurements.

Methods: A novel deformable phantom consisting of flexible foam, emulating lung tissue, inside a Lucite external body was constructed.

View Article and Find Full Text PDF

During the HIV/AIDS epidemic of the 1980s, most of the developed world instituted a permanent ban on blood donations from men who have sex with men (MSM). In recent years, public health agencies across Europe and North America are reconsidering and rescinding these restrictions. We examine the Canadian climate, where MSM may donate blood only after a 5-year deferral period.

View Article and Find Full Text PDF

Purpose: To evaluate a novel 4D Monte Carlo simulation tool by comparing calculations to physical measurements using a respiratory motion phantom.

Methods: We used a dynamic Quasar phantom in both stationary and breathing states (sinusoidal motion of amplitude of 1.8 cm and period of 3.

View Article and Find Full Text PDF

This work retrospectively investigates patient-specific Monte Carlo (MC) dose calculations for (103)Pd permanent implant breast brachytherapy, exploring various necessary assumptions for deriving virtual patient models: post-implant CT image metallic artifact reduction (MAR), tissue assignment schemes (TAS), and elemental tissue compositions. Three MAR methods (thresholding, 3D median filter, virtual sinogram) are applied to CT images; resulting images are compared to each other and to uncorrected images. Virtual patient models are then derived by application of different TAS ranging from TG-186 basic recommendations (mixed adipose and gland tissue at uniform literature-derived density) to detailed schemes (segmented adipose and gland with CT-derived densities).

View Article and Find Full Text PDF

A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (S(c,p))(f(clin))(det), for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied for the RL detector response for the 5, 7.5 and 10 mm collimators in order to correct for the detector geometry and increased photoelectric cross section of Al2O3:C relative to water.

View Article and Find Full Text PDF

The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD), it is established that real-time IVD can provide efficient error detection and treatment verification.

View Article and Find Full Text PDF

Purpose: In this report the authors present the validation of a Monte Carlo dose calculation algorithm (XiO EMC from Elekta Software) for electron beams.

Methods: Calculated and measured dose distributions were compared for homogeneous water phantoms and for a 3D heterogeneous phantom meant to approximate the geometry of a trachea and spine. Comparisons of measurements and calculated data were performed using 2D and 3D gamma index dose comparison metrics.

View Article and Find Full Text PDF

Purpose: The in vivo dosimetry tool, RADPOS, has been modified to include a metal oxide-silicon semiconductor field effect transistor (MOSFET) array with an electromagnetic positioning sensor. This allows dose monitoring at five points rather than just at single dose point as in the other versions of the device. The detector has been used in a clinical trial, which is the first to measure both urethral dose and internal motion concurrently during permanent seed implantation for prostate brachytherapy using a single probe.

View Article and Find Full Text PDF

In vivo dosimetry (IVD) has been used in brachytherapy (BT) for decades with a number of different detectors and measurement technologies. However, IVD in BT has been subject to certain difficulties and complexities, in particular due to challenges of the high-gradient BT dose distribution and the large range of dose and dose rate. Due to these challenges, the sensitivity and specificity toward error detection has been limited, and IVD has mainly been restricted to detection of gross errors.

View Article and Find Full Text PDF

The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators.

View Article and Find Full Text PDF

Purpose: To determine the effect of different bleaching wavelengths on the response of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams.

Methods: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.

View Article and Find Full Text PDF

Novel dosimetry systems based on Al O :C radioluminescence (RL) and a 4D dosimetry system (RADPOS) from Best Medical Canada were used to measure the relative output factor (ROF) on Cyberknife. Measurements were performed in a solid water phantom at the depth of 1.5 cm and SSD = 78.

View Article and Find Full Text PDF