Publications by authors named "Cuypers H"

Epidemiological studies have reported on the detrimental effects on lung function after natural, and thus limited, weight gain in unselected populations. Studies on bariatric surgery, on the contrary, have indicated large improvements in lung function after substantial weight loss. To study the associations between profound weight loss or gain and pulmonary function within the same population.

View Article and Find Full Text PDF

Infection with a genotype G strain of hepatitis B virus (HBV-G) often occurs as a co-infection with HBV genotype A. In mono-infection with HBV-G, the production of hepatitis B surface antigen (HBsAg), HBe antigen and anti-HBe seems diminished, hampering the serological diagnosis of HBV-G mono-infection. To corroborate this notion, we studied in detail a series of samples of a blood donor with transient HBV-G infection.

View Article and Find Full Text PDF

Clinical management of short bowel syndrome remains a multistage process. Although PN is crucial, early introduction of enteral feeding is mandatory. We describe retrospectively 4 patients with an ultrashort bowel who could be weaned off PN on very short terms after introduction of an amino-acid-based formula (Neocate).

View Article and Find Full Text PDF

Background And Objectives: Parvovirus B19 (B19V) DNA screening has been introduced to comply with European regulations for certain plasma products. Current commercial and some in-house B19V DNA assays fail to detect or under-quantify the recently identified genotypes 2 and 3. In this report, we describe 2-year experience with B19V DNA screening using the commercial assay from Roche (detecting only genotype 1) combined with an in-house assay (detecting genotypes 1, 2 and 3).

View Article and Find Full Text PDF

Background And Objectives: West Nile virus (WNV) can be transmitted by transfusion through infected blood components. This study aimed to determine the prevalence of WNV infection among Dutch blood donors to assess whether WNV is a possible threat for the Dutch blood supply.

Materials And Methods: Plasma samples from 61 992 blood donations were pooled in 7,749 test pools of eight donations using a Tecan robot.

View Article and Find Full Text PDF

Background And Objectives: This report describes the evaluation of the COBAS AmpliPrep instrument for fully automated generic nucleic acid extraction in conjunction with hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA, and human immunodeficiency virus (HIV)-1 RNA COBAS AmpliScreen amplification and detection using serial dilutions of the WHO international standards (IS) and the PeliCheck reference panels.

Materials And Methods: Serial diluted samples of the WHO IS and the PeliCheck reference panels were tested 24 times to determine the HBV DNA, HCV RNA and HIV-1 RNA detection limits by Probit analysis. The existence and extent of cross-contamination were assessed by testing alternating high titre HBV DNA-positive and -negative samples.

View Article and Find Full Text PDF

Background: The performance of the recently launched Procleix Ultrio (Chiron/Gen-Probe) human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) blood screening assay was evaluated in a European multicenter study.

Study Design And Methods: Serial dilutions of reference materials were tested to determine the detection limits. Robustness and specificity were assessed by testing alternating high-load HCV RNA-positive and -negative samples, and 2912 test pools of eight donations.

View Article and Find Full Text PDF

The Nuclisens EasyQ HIV-1 v1.1 assay (Biomerieux) is a real-time detection method combined with NASBA technology designed to measure plasma HIV-RNA. Its performance was assessed in 1008 clinical specimens collected from individuals infected with clade B (774) and non-B (234) HIV-1 variants at four European laboratories.

View Article and Find Full Text PDF

Background: As of 2004, the European Pharmacopoeia demands that plasma pools for production of anti-D immunoglobulin should not contain more than 104 IU per mL of parvovirus B19 (B19V) DNA. Hence, before pooling, highly viremic donations have to be identified, and after pooling the level of B19V DNA must be determined. The performance of a new real-time B19V DNA PCR test (Roche, Mannheim, Germany) was studied, using a DNA extractor (NucliSens, bioMerieux, Boxtel, the Netherlands) for isolation of nucleic acid, and using a DNA quantification test (LightCycler apparatus, Roche, Mannheim, Germany) for amplification and detection.

View Article and Find Full Text PDF

Background: The FDA requirement for sensitivity of viral NAT methods used in blood screening is a 95-percent detection limit of 100 copies per mL, whereas the NAT screening system should have a sensitivity of at least 5000 copies per mL per individual donation. According to the Common Technical Specifications of the European Directive 98/79/EC for in vitro diagnostics, viral standard dilutions (calibrated against the WHO standard) should be tested at least 24 times for a statistically valid assessment of the 95-percent detection limit.

Study Design And Methods: Viral standard dilution panels (PeliCheck, VQC-CLB) were prepared for HCV RNA genotypes 1 and 3 and for HIV RNA genotypes B and E.

View Article and Find Full Text PDF

Background: In patients with chronic hepatitis C (HCV) Interferon-alpha (IFN) treatment for 12-18 months is more effective than 6 months in inducing a sustained virological response.

Methods: In a multicenter, randomized, controlled trial, 88 patients with chronic HCV were enrolled (47 treated with IFN-alpha2b and 41 constituted an untreated control group). Treatment consisted of 5 million units (MU) IFN thrice a week (tiw) for 8 weeks and subsequently 2.

View Article and Find Full Text PDF

Aims: To use laboratory data and liver biopsies, prospectively obtained from hepatitis B surface antigen (HBsAg) and anti hepatitis B e antigen (anti-HBe) positive patients, for the assessment of: (1) the relation between biopsy length/number of portal tracts and sampling error; (2) the relation between the severity of piecemeal necrosis and the new grading terminology (minimal, mild, moderate, and severe chronic hepatitis); and (3) liver pathology, which has not been studied in patients with this specific serological profile.

Methods: The study group (n = 174) included 104 patients with normal aminotransferase concentrations and no cases with clinically apparent cirrhosis. The specimen length and number of portal tracts were measured at light microscopy examination.

View Article and Find Full Text PDF

The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guidelines were followed.

View Article and Find Full Text PDF

A quantitative nucleic acid sequence-based amplification assay (NASBA-QT) for detection of hepatitis C virus RNA (HCV-RNA) was evaluated and compared with the HCV branched-DNA (bDNA) assay (Chiron Corporation) and the HCV MONITOR assay (Roche Diagnostic Systems). For this evaluation five panels were designed: (1) serial dilutions of genotype 1b in-vitro HCV-RNA; (2) standards of in-vitro HCV-RNA genotypes 1a, 1b, 2, 3, 4, and 5; (3) a proficiency panel consisting of 12 HCV-RNA positive plasma samples of different genotypes and HCV-RNA concentrations and a genotype 1a and 1b 3-fold dilution series; (4) a panel of 67 HCV-RNA positive plasma samples obtained from patients with HCV infection and (5) an HCV-RNA positive control sample, diluted 50-fold in 25 different HCV-RNA negative plasma samples. The quantitative detection limit was found to be 10(3) copies per 100 microl and the qualitative detection limit 10(2.

View Article and Find Full Text PDF

The prevalence of hepatitis G virus (HGV)-RNA and HGV-E2 antibodies was studied in a cohort of Dutch hemophilia patients in relation to clotting products used, age, and coinfection with hepatitis C. Between 1991 and 1995, blood samples were taken from 294 patients with hemophilia A, B, or von Willebrand disease. From each patient one fresh frozen sample was tested for HGV cDNA polymerase chain reaction (PCR) and HCV cDNA PCR.

View Article and Find Full Text PDF

Background: Used as a supplemental assay, new anti-human immunodeficiency virus (HIV) immunoblots, employing recombinant and synthetic antigens, appeared to resolve the majority of samples with false-reactive Western blot results. Would it be possible to completely replace the Western blot by an immunoblot for confirmation and exclusion of HIV infection?

Study Design And Methods: The sensitivity of the new LiaTek HIV III immunoblot assay (Organon Teknika, Turnhout, Belgium) was tested on 416 Western-blot positive samples (386 HIV-1, 22 HIV-2, 1 HIV-1/2, and 7 HIV-O) and on 45 HIV-1 seroconversion samples. The specificity was tested on 146 samples from noninfected donors with false-positive results on a HIV screening test.

View Article and Find Full Text PDF

The influence of different anticoagulants and pre-amplification storage conditions on the stability of hepatitis C virus (HCV)-RNA, as detected by the quantitative HCV NASBA assay (NASBA-QT), was studied. The HCV-RNA load remained stable for at least 15 months when serum or plasma samples (EDTA and heparin) were directly frozen at -70 degrees C in lysis buffer. At 4 degrees C, the HCV-RNA load in serum or plasma stored with lysis buffer did not decline for at least 14 days.

View Article and Find Full Text PDF

Background: Hepatitis B surface antigen (HBsAg) and antibodies to hepatitis B e antigen (anti-HBe) commonly coexist, and laboratory tests are often requested to assess histological hepatitis activity. An optimum panel of tests has not been found and the usefulness of hepatitis B virus (HBV) DNA assays in this context has not been established. We assessed various blood tests to find which best predicted hepatitis activity.

View Article and Find Full Text PDF

Background: Envelope mutant forms of hepatitis B virus (HBV), impairing HBV antibody recognition, have been reported with mutations in single or multiple sites of the hepatitis B surface antigen (HBsAg) group-specific "a" determinant. Blood donors infected with such an HBsAg mutant form of HBV may escape detection by HBsAg screening assays and therefore may affect the safety of the blood supply.

Case Report: A repeat blood donor became HBsAg-reactive in an enzyme immunoassay.

View Article and Find Full Text PDF

The influence of different storage temperatures and anticoagulation conditions on the HIV-1 RNA load as measured by NASBA-QT was examined. Blood specimens from 14 HIV-1 infected individuals were processed within 2 h after collection. The HIV-1 RNA load remained stable for at least 6 months when samples were frozen directly at -70 degrees C in lysis buffer.

View Article and Find Full Text PDF

Background: Prevention of posttransfusion non-A,non-B hepatitis in recipients of blood components improved considerably with the introduction of the second-generation of hepatitis C virus (HCV) antibody tests. In 1993, third-generation HCV antibody assays were introduced in Europe.

Study Design And Methods: The performance of three generations of anti-HCV enzyme-linked immunosorbent assay (ELISA) (ELISA-1, -2, -3) was compared in routine blood donor screening (99,394 donations were tested with ELISA-1, 167,999 donations with ELISA-2, and 262,090 donations with ELISA-3) and in serial samples from nine patients with documented acute posttransfusion HCV infection.

View Article and Find Full Text PDF

The activator-encoding gene phlR was identified upstream of the plasmid-encoded operon for phenol degradation in Pseudomonas putida strain H by cassette mutagenesis and DNA sequence analysis. The deduced amino acid sequence of PHLR shows high homology to DmpR of P. putida sp.

View Article and Find Full Text PDF

Background/aims: Hepatitis G virus is a recently characterized transfusion-transmissible RNA virus. Its pathogenicity remains to be established. We studied its prevalence in liver transplant patients and assessed the long-term influence on the liver graft.

View Article and Find Full Text PDF