  • The study aimed to evaluate a motion correction algorithm (MCA) for enhancing image quality in CT angiography at high heart rates.
  • Two blinded observers assessed the quality of images generated using MCA versus a conventional algorithm (CA) across various heart rates and energy levels.
  • The findings showed that MCA significantly improved image quality and interpretability, especially at heart rates of 90-100 beats/min and lower energy settings (50-70 keV).
View Article and Find Full Text PDF

To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s.

View Article and Find Full Text PDF

Cardiac hydatid cysts are uncommon but potentially fatal. We present a case of isolated unilocular and multivesicular hydatid cysts in the heart, and provide a literature review of this rare condition. A 35-year-old man presented to our cardiology unit with acute chest pain.