Publications by authors named "Critchfield L"

Treating multiple lung lesions synchronously using a single-isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) plan can improve treatment efficiency and patient compliance. However, due to set up uncertainty, aligning multiple lung tumors on a single daily cone beam CT (CBCT) image has shown clinically unacceptable loss of target(s) coverage. Herein, we propose a Restricted Single-Isocenter Stereotactic Body Radiotherapy (RESIST), an alternative treatment that mitigates patient setup uncertainties.

View Article and Find Full Text PDF

Synchronous treatment of two lung lesions using a single-isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) plan can decrease treatment time and reduce the impact of intrafraction motion. However, alignment of both lesions on a single cone beam CT (CBCT) can prove difficult and may lead to setup errors and unacceptable target coverage loss. A Restricted Single-Isocenter Stereotactic Body Radiotherapy (RESIST) method was created to minimize setup uncertainties and provide treatment delivery flexibility.

View Article and Find Full Text PDF

Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for selected lung cancer patients. Four-dimensional (4D) CT-based treatment plans were generated using advanced AcurosXB algorithm with heterogeneity corrections using an SBRT board and Halcyon couch insert. Halcyon VMAT-SBRT plans with stacked and staggered multileaf collimators produced highly conformal radiosurgical dose distribution to the target, lower intermediate dose spillage, and similar dose to adjacent organs at risks (OARs) compared to SBRT-dedicated highly conformal clinical noncoplanar Truebeam VMAT plans following the RTOG-0813 requirements.

View Article and Find Full Text PDF

Treating multiple lung lesions synchronously via single-isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) improves treatment efficiency and patient compliance. However, aligning multiple lung tumors accurately on single pretreatment cone beam CTs (CBCTs) can be problematic. Tumors misaligned could lead to target coverage loss.

View Article and Find Full Text PDF

Purpose A single-isocenter volumetric modulated arc therapy (VMAT) treatment to multiple brain metastatic patients is an efficient stereotactic radiosurgery (SRS) option. However, the current clinical practice of single-isocenter SRS does not account for patient setup uncertainty, which degrades treatment delivery accuracy. This study quantifies the loss of target coverage and potential collateral dose to normal tissue due to clinically observable isocenter misalignment.

View Article and Find Full Text PDF

Our patient is a 48-year-old gentleman who initially was diagnosed with stage IV colorectal cancer on presentation. He had a history of multiple lines of systemic therapy, primary local resection, radioembolization treatments to the liver, along with liver metastasectomy with intraoperative radiofrequency ablation. He initially presented and completed single-isocenter stereotactic body radiation therapy (SBRT) to five right lung metastases with a treatment response and then completed SBRT to two additional right lower lung metastases.

View Article and Find Full Text PDF