Publications by authors named "Crins L"

Objectives: This study aimed to develop and evaluate a fully automated method for visualizing and measuring tooth wear progression using pairs of intraoral scans (IOSs) in comparison with a manual protocol.

Methods: Eight patients with severe tooth wear progression were retrospectively included, with IOSs taken at baseline and 1-year, 3-year, and 5-year follow-ups. For alignment, the automated method segmented the arch into separate teeth in the IOSs.

View Article and Find Full Text PDF

Purpose: This study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP).

Materials And Methods: Four dental resin composites were selected. 30 discs (Ø12.

View Article and Find Full Text PDF

Objectives: Aim of this prospective study was to assess full mouth rehabilitation of severe tooth wear patients using minimally invasive CAD/CAM resin-based composite (RBC) restorations and direct veneers by evaluating restoration survival up to 5.5-years.

Methods: Twenty-two patients with generalized severe tooth wear with functional and/or esthetic problems were included.

View Article and Find Full Text PDF

Patients with tooth wear are commonly encountered in general dental practice. When indicated, restorative rehabilitation is often accompanied by a request from the patient for an aesthetic, tooth-coloured outcome. This article seeks to provide an evidence-based approach, focussing on the longevity of the materials which can be used for the restorative treatment of tooth wear, as well as their modes of failure and observed performance.

View Article and Find Full Text PDF
Article Synopsis
  • Non-carious tooth wear can cause both functional issues and dissatisfaction with dental aesthetics, negatively affecting a person's oral health quality of life (OHRQoL).
  • This study evaluated the long-term impacts of restorative treatment on tooth wear patients' OHRQoL and aesthetic perceptions over five years using specific questionnaires before and after treatment.
  • Results showed significant improvements in OHRQoL and aesthetic appreciation immediately after and sustained through the five-year follow-up, indicating the lasting benefits of restorative dental work.
View Article and Find Full Text PDF

A 24-year-old patient with generalized tooth wear was referred to the Radboud Tooth Wear Project. The tooth wear had a chemical aetiology, caused by gastro-oesophageal reflux and resulting in functional problems of the masticatory system and a reduced quality of life. The treatment of the patient was minimally invasive, with directly applied composite restorations on all teeth, by means of which an increase of vertical dimension of occlusion was introduced.

View Article and Find Full Text PDF

Background: Evaluation of a new vertical dimension of occlusion (VDO) in complex restorative treatments is considered a necessary step prior to placement of restorations.

Objectives: This randomised controlled trial (RCT) aimed to assess the effects of using an evaluation of a VDO increase before restorative treatment in patients with moderate-to-severe tooth wear, on OHRQoL, freeway space (FWS) and interventions to restorations.

Methods: Forty-two patients with tooth wear were included and randomly allocated to either a test phase with a Removable Appliance (RA) or no test phase.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the wear behaviour of direct composite restorations after 5 years and associated patient factors.

Methods: 38 patients (6 females, 32 males; 35.2 ± 7.

View Article and Find Full Text PDF

Objectives: Deterioration in anterior resin composite restorations placed in tooth wear patients was investigated after 36 months.

Materials And Methods: Data collected prospectively for 47 participants of the Radboud Tooth Wear Project were used (41 ± 8 years, 90% male, n = 270 restorations). Restorations were individually evaluated using intraoral photographs and 3D scans to rate modified FDI scores and to record the presence of degradation features.

View Article and Find Full Text PDF

Purpose: To describe the digital workflow applied for restoring a severely worn dentition with minimally invasive CAD/CAM resin nano-composite restorations.

Materials And Methods: A 40-year-old male in good general health and with full-arch dentition suffered from dentin hypersensitivity and wanted to improve the esthetics of his worn anterior teeth. The dental wear can be described as general, grade 3, according to the Tooth Wear Index,27 with more wear in maxillary than in mandibular teeth.

View Article and Find Full Text PDF

Purpose: The aim of this prospective study was to evaluate the clinical performance of minimally invasive, CAD/CAM nano-ceramic (composite) restorations in patients with severe tooth wear, the effect of the restorative treatment on the oral health-related quality of life (OHRQoL), and the etiology of tooth wear as a risk factor for restoration failure.

Materials And Methods: Patients with generalized severe tooth wear were included. Restorations (LAVA Ultimate, 3M Oral Care) were cemented (RelyX Ultimate, 3M Oral Care) on all teeth and were evaluated after 1 month and 1 year.

View Article and Find Full Text PDF

Objective: The study aimed to evaluate survival and failure behavior of Direct Composite Restorations (DRC) and Indirect Composite Restorations (ICR) on molars and anterior teeth, in a Randomized Controlled Trial (RCT).

Methods: Patients with generalized severe tooth wear were included, and randomly assigned to one of 2 protocols: (1) DCR: All teeth were restored with directly applied micro-hybrid composite restorations (Clearfil AP-X, Kuraray) for load bearing areas and nano-hybrid composite restorations (IPS Empress Direct, Ivoclar Vivadent) for buccal veneers; (2) ICR: First molars were restored with indirect composite 'tabletop' restorations and maxillary anterior teeth were restored with indirect palatal veneer restorations (Clearfil Estenia C&B, cemented with Panavia F, Kuraray). Remaining teeth were restored directly.

View Article and Find Full Text PDF

Objectives: To evaluate the 5.5-year performance of direct resin composite restorations, prescribed for patients with severe tooth wear, requiring full-mouth rehabilitation.

Methods: A convenience sample of 34 patients were recruited to a prospective trial between December 2010 and June 2013.

View Article and Find Full Text PDF

Objectives: To investigate the effects of the level of pre-treatment tooth wear and increasing the VDO on the performance of direct resin composite restorations for the rehabilitation of pathological tooth wear.

Methods: Full-mouth (pre-treatment) grading was performed on digital greyscale scan records for 34 participants (35.3 ± 8.

View Article and Find Full Text PDF

Background: The Tooth Wear Evaluation System (TWES) is a type of tooth wear index. To date, there is the lack of data comparing the reliability of the application of this index on gypsum cast records and digital greyscale intra-oral scan records.

Objectives: A comparative evaluation between the use of gypsum cast records and digital greyscale intra-oral scan records with the reliability of tooth wear scoring using the TWES amongst a group of patients with tooth wear.

View Article and Find Full Text PDF

Background: Three-dimensional scans are increasingly used to quantify biological topographical changes and clinical health outcomes. Traditionally, the use of 3D scans has been limited to specialized centers owing to the high cost of the scanning equipment and the necessity for complex analysis software. Technological advances have made cheaper, more accessible methods of data capture and analysis available in the field of dentistry, potentially facilitating a primary care system to quantify disease progression.

View Article and Find Full Text PDF