Little is known about the effect of cardiopulmonary bypass alone on cardiac function; in an attempt to illuminate this relationship and test a possible mechanism, we used Cytosorb, a device capable of removing virtually all types of circulating cytokines to test the hypothesis that hemoadsorption of cytokines during bypass attenuates bypass-induced acute organ dysfunction. Twelve Yorkshire pigs (50-65 kg) were instrumented with a left ventricular conductance catheter. Baseline mechanics and cytokine expression (tumor necrosis factor [TNF], interleukin-6 [IL-6], and interleukin-10) were measured before and hourly after 1 hour of normothermic cardiopulmonary bypass.
View Article and Find Full Text PDFBackground: Clinical studies conducted to elucidate the systemic response to cardiopulmonary bypass (CPB) did not differentiate possible effect of different types of cardiac surgical pathologies and operations on outcomes and have typically combined different procedures. We hypothesized that valve surgery induces more prominent systemic reaction compared to isolated on-pump CABG.
Methods: Twenty-seven patients undergoing primary on-pump CABG (Group 1, n = 14) or valve surgery with or without CABG (Group 2, n = 13) were prospectively enrolled.
Heparin-coated circuits have been repeatedly proven to reduce the inflammatory response and foreign surface activation triggered upon initiation of cardiopulmonary bypass (CPB). In recent years, increasing numbers of studies are proving significant reductions in postoperative blood loss and transfusion requirements and improvements in clinical outcomes as a result of heparin-coated circuits. These results are promising steps in our efforts to improve CPB, as our patient population gets older and more complicated.
View Article and Find Full Text PDFA 37-year-old male with mitral valve regurgitation presented for mitral valve replacement. He has been a C5 quadriplegic for 13 years. The patient had been discharged 2 months before to this admission after a complicated hospital course for Staphylococcus aureus infection of the left hip.
View Article and Find Full Text PDFObjective: The objective of this study was to examine the mechanism of procoagulant activity and inhibition in whole blood during extracorporeal circulation.
Methods: In this study we examine the development of procoagulant activity and monocyte activation in heparinized whole blood passing through a closed circuit consisting of a pump and silicone envelope membrane oxygenator for 6 hours.
Results: Anaphylatoxins, C3a and C5a, determined by means of enzyme-linked immunosorbant assay, appeared in the blood within 30 minutes of circulation.
Objective: Reports evaluating the efficacy of heparin-bonded circuits to blunt inflammation, platelet dysfunction, and thrombin generation in response to cardiopulmonary bypass have varied. We hypothesized that this variability may in part be related to the use of cardiotomy suction, which has been demonstrated to reintroduce procoagulant and proinflammatory factors into the systemic circulation during cardiopulmonary bypass. A prospective, randomized study was undertaken to evaluate the specific effects of cardiotomy suction.
View Article and Find Full Text PDF