Background: Ultra-low dose computed tomography (ULD-CT) was shown to be a good alternative to digital radiographs in various locations. This study aimed to assess the diagnostic sensitivity and specificity of ULD-CT versus digital radiographs in patients consulting for extremity traumas in emergency room.

Methods: Digital radiography and ULD-CT scan were performed in patients consulting at the emergency department (February-August 2018) for extremity traumas.

View Article and Find Full Text PDF

Introduction: Ultrasound-guidance of radial artery catheter insertion improves the first attempt success and reduces the occurrence of hematomas. Needle-tracking devices optimize needle-ultrasound beam alignment by displaying in real-time the needle tip position. We compared the median time need by experienced physicians to achieve radial artery puncture using either a conventional ultrasonography device (CUD) or a magnetic needle-tracking ultrasound device (MUD) in a simulation training arm model.

View Article and Find Full Text PDF

Introduction: Ultrasound is a feasible and reproducible method for measuring right diaphragmatic excursion (RDE) in ED patients with acute dyspnea (AD). In AD patients, the correlation between the RDE value and the need for mechanical ventilation (MV) is not known.

Materials: This was a bicentric, observational prospective study.

View Article and Find Full Text PDF

Objectives: Global longitudinal strain (GLS) appears sensitive and reproducible to identify left ventricular systolic dysfunction. The main objective was to analyze the GLS changes in an anesthetized-piglet model of controlled hemorrhagic shock (HS). The secondary objective was to evaluate if GLS changes was different depending on the expansion fluid treatment with or without norepinephrine.

View Article and Find Full Text PDF

Objective: Minimizing out-of-hospital time reduces morbidity and mortality in patients with severe trauma, acute coronary syndrome, or acute stroke. Our objective was to compare out-of-hospital times by helicopter versus ground services when the estimated time of arrival on the scene was over 20 minutes.

Methods: We proposed a retrospective observational monocentric study following 2 cohorts.

View Article and Find Full Text PDF

Background: Ultrasound (US) guidance has yet to prove its applicability in radial arterial blood gas analysis (ABGA) punctures. The main objective of our study was to compare the number of first-attempt successes (NFAS) for radial arterial puncture in difficult patients with or without US guidance. The Secondary aims were to compare the number of punctures (NOP), puncture time, and patient pain.

View Article and Find Full Text PDF

Study Objective: To evaluate the diagnostic performance of chest ultralow-dose computed tomography (CT) compared with chest radiograph for minor blunt thoracic trauma.

Methods: One hundred sixty patients with minor blunt thoracic trauma were evaluated first by chest radiograph and subsequently with a double-acquisition nonenhanced chest CT protocol: reference CT and ultralow-dose CT with iterative reconstruction. Two study radiologists independently assessed injuries with a structured report and subjective image quality and calculated certainty of diagnostic confidence level.

View Article and Find Full Text PDF

Introduction: The aims of our study were to compare the performance of experienced emergency physicians for internal jugular vein puncture using a conventional ultrasound device versus a pocket-sized ultrasound in a training model.

Methods: In this single-center, prospective, randomized study, emergency physicians performed one puncture with each device in a randomized order. No emergency physicians used a pocket-sized ultrasound for central vascular catheter insertion in clinical practice.

View Article and Find Full Text PDF

Background: The correlation between cardiac output (CO) evaluated by echocardiography and CO measured by thermodilution (COth) varies according to different studies. A new transthoracic echocardiography (TTE) tool allows automatic calculation of the subaortic velocity time index (VTIauto) and CO (COauto). The main objective was to evaluate the correlation between COth and COauto in an anesthetized, ventilated piglet hemorrhagic shock (HS) model.

View Article and Find Full Text PDF

Introduction: Compression ultrasonography (CUS) is a validated technique for the diagnosis of deep venous thrombosis (DVT), but has never been studied with pocket-sized ultrasound device (PUD). The main objective of this study was to assess the diagnostic performance of CUS made by emergency physicians (EPs) using a PUD.

Materials: This was a prospective, diagnostic test assessment, single-center study.

View Article and Find Full Text PDF

Introduction: The present study was aimed at comparing the diagnosis concordance of five echo probes of lung ultrasound (LUS) with CT scans in intensive care and emergency patients with acute respiratory failure.

Materials: This prospective, observational, pilot study involved 10 acute patients in whom a thoracic CT scan was performed. An expert performed an LUS reference exam using five different probes: three probes with a high-quality conventional echo machine (cardiac phased-array probe, abdominal convex probe, linear probe) and two probes (cardiac and linear) with a pocket ultrasound device (PUD).

View Article and Find Full Text PDF

Introduction: Misdiagnosis in acute dyspneic patients (ADP) has consequences on their outcome. Lung ultrasound (LUS) is an accurate tool to improve diagnostic performance. The main goal of this study was to assess the determinants of increased diagnostic accuracy using LUS.

View Article and Find Full Text PDF

Background: After general anaesthesia (GA) in adults, the optimal tracheal extubation technique (positive pressure or suctioning) remains debated. The primary endpoint of this study was to assess the effects of these techniques on onset time of desaturation (SpO<92%).

Methods: Sixty-nine patients with a body mass index<30 scheduled for elective orthopaedic surgery were allocated to positive pressure (PP) or suctioning (SUC) group.

View Article and Find Full Text PDF

Objective: Ensuring the availability of ultrasound devices is the initial step in implementing clinical ultrasound (CUS) in emergency services. In France in 2011, 52% of emergency departments (EDs) and only 9% of mobile intensive care stations (MICS) were equipped with ultrasound devices. The main goal of this study was to determine the movement of these rates since 2011.

View Article and Find Full Text PDF

Objective: The main objectives of our study were to evaluate the prevalence of emergency point-of-care ultrasound (POCUS) use and to assess the impact of POCUS on: diagnostic, therapeutic, patient orientation and imaging practices.

Methods: This was a one-day, prospective, observational study carried out across multiple centers. Fifty emergency departments (EDs) recorded all POCUS performed over a 24h period.

View Article and Find Full Text PDF

Introduction: Presepsin (sCD14-ST) is an emerging biomarker for infection. We hypothesized that presepsin could specifically increase during acute pyelonephritis and correlate with severity.

Methods: We compared presepsin values in patients with acute pyelonephritis and controls, and we assessed its capacity to predict bacteraemia and admission in patients.

View Article and Find Full Text PDF

The Région Languedoc Roussillon is the umbrella organisation for an interconnected and integrated project on active and healthy ageing (AHA). It covers the 3 pillars of the European Innovation Partnership on Active and Healthy Ageing (EIP on AHA): (A) Prevention and health promotion, (B) Care and cure, (C) and (D) Active and independent living of elderly people. All sub-activities (poly-pharmacy, falls prevention initiative, prevention of frailty, chronic respiratory diseases, chronic diseases with multimorbidities, chronic infectious diseases, active and independent living and disability) have been included in MACVIA-LR which has a strong political commitment and involves all stakeholders (public, private, patients, policy makers) including CARSAT-LR and the Eurobiomed cluster.

View Article and Find Full Text PDF

Background: Sore throat is a common complaint after surgery. It affects patient satisfaction and can affect activity after discharge. The supraglottic airway device (SAD) offers an alternative to traditional tracheal intubation with potential benefit in preventing sore throat.

View Article and Find Full Text PDF

Objectives: Adverse drug events are the sixth-leading cause of death in Western countries and are also more frequent in emergency departments (EDs). In some hospitals or on some occasions, ED physicians prescribe for patients who they have admitted. These prescriptions are then followed by the wards and can persist for several days.

View Article and Find Full Text PDF