Background: Point-of-care (POC) testing equipment is commonly utilized in outpatient clinics. Our institution recently interfaced POC chemistry and hematology devices at two outpatient clinics via middleware software to the central electronic health record (EHR), facilitating a comparison of manual transcription versus automatic reporting via interface. This allowed for estimation of serious/obvious error rates and manual time savings.
View Article and Find Full Text PDFObjectives: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population.
Design And Methods: Retrospective study was done over an approximately 3.5 year period.
The measurement of free immunoglobulin light chains is typically performed on serum; however, the use of alternative specimen types has potential benefits. Using the Freelite™ kappa and lambda free light chains assay on a Roche Diagnostics cobas 8000 c502 analyzer, we compared three specimen types (serum, EDTA-plasma and lithium heparin plasma separator gel-plasma) on 100 patients. Using Deming regression and eliminating outliers (limiting data to light chain concentrations below 400 mg/L), the three specimen types showed comparable results for kappa light chain concentration, lambda light chain concentration, and kappa/lambda ratio with slopes close to 1.
View Article and Find Full Text PDFBackground: Pentobarbital is used for management of intractable seizures and for reducing elevated intracranial pressure. Dosing of pentobarbital can be aided by therapeutic drug monitoring (TDM). There is no commercially available automated assay for measurement of pentobarbital serum/plasma concentrations; consequently, chromatography-based assays are often used.
View Article and Find Full Text PDFEthylene glycol (EG) is a common cause of toxic ingestions. Gas chromatography (GC)-based laboratory assays are the gold standard for diagnosing EG intoxication. However, GC requires specialized instrumentation and technical expertise that limits feasibility for many clinical laboratories.
View Article and Find Full Text PDFBackground: Immunoassays are widely used in clinical laboratories for measurement of plasma/serum concentrations of steroid hormones such as cortisol and testosterone. Immunoassays can be performed on a variety of standard clinical chemistry analyzers, thus allowing even small clinical laboratories to do analysis on-site. One limitation of steroid hormone immunoassays is interference caused by compounds with structural similarity to the target steroid of the assay.
View Article and Find Full Text PDFBackground: Autoverification is a process of using computer-based rules to verify clinical laboratory test results without manual intervention. To date, there is little published data on the use of autoverification over the course of years in a clinical laboratory. We describe the evolution and application of autoverification in an academic medical center clinical chemistry core laboratory.
View Article and Find Full Text PDFA rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard. The method employed a single-step derivitization using phenylboronic acid, was linear to 200 mg/dL and had a lower limit of quantitation of 1 mg/dL suitable for clinical analyses. The analytical method described allows for laboratories with HS-GC instrumentation to analyze ethanol, methanol, isopropanol, ethylene glycol, and propylene glycol on a single instrument with rapid switch-over from alcohols to glycols analysis.
View Article and Find Full Text PDFBackground: Hepatitis B virus (HBV) is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg) are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients.
View Article and Find Full Text PDF