Cavity disinfection is necessary to prevent a progressive infection of the crown dentin and pulp. Increasing intolerance and resistance to antiseptics and antibiotics as well as the controversy over the effects of those on the dental hard tissue and composite have prompted the investigation of alternative treatment options. The objective of this pilot study is to evaluate the antibacterial potential of a diode laser with a wavelength of 445 nm in the cavity preparation using the bacterium associated with caries in conjunction with the characteristics and influences of dentin on light transmission.
View Article and Find Full Text PDFAims: The aim of this study was to compare force loss due to friction (Fr) during simulated canine retraction using different archwire dimensions and materials between conventional and new self-ligating brackets.
Methods: The tested brackets were (1) conventional brackets (Victory series, GAC twin and FLI twin), (2) self-ligating brackets (Damon-Q, FLI-SL, new/improved FLI-SL (I FLI-SL), SPEED, GAC innovation (R) and Ortho Classic) and (3) a low-friction bracket (Synergy). All brackets had a 0.
Background/objective: The aim of this study was to evaluate the efficacy of tooth alignment with conventional and self-ligating labial and lingual orthodontic bracket systems.
Materials/methods: We tested labial brackets (0.022″ slot size) and lingual brackets (0.
Am J Orthod Dentofacial Orthop
January 2018
Introduction: The aim of this study was to analyze the time-dependent in-vitro behavior of the periodontal ligament (PDL) by determining the material parameters using specimens of porcine jawbone. Time-dependent material parameters to be determined were expected to complement the results from earlier biomechanical studies.
Methods: Five mandibular deciduous porcine premolars were analyzed in a combined experimental-numeric study.
Background/objective: The aim of this study was to evaluate force levels exerted by levelling arch wires with labial and lingual conventional and self-ligating brackets.
Materials/methods: The tested orthodontic brackets were of the 0.022-in slot size for labial and 0.
Aims: The goal was to determine the influence of different geometric parameters of the tooth on the initial tooth mobility and the position of the center of resistance employing numerical models based on scaled X-ray images and plaster casts.
Methods: The dimensions of tooth 21 were measured in 21 patients, using radiographs and dental casts. Length and mesiodistal width of the tooth were obtained from the X-ray image and the orovestibular diameter from the plaster cast.
Aims: The goal of this study was to determine the mechanical properties of different esthetic and conventional orthodontic wires in three-point and four-point bending tests, and in a biomechanical test employing three bracket systems.
Methods: The behavior of round wires with a diameter of 0.46 mm (0.
Statement Of Problem: Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery.
Purpose: The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up.
Objectives: Self-ligating brackets are widely believed to offer better clinical efficiency and, in particular, less friction. Thus, the goal of this in vitro investigation was to assess the friction behavior of different bracket/archwire/ligature combinations during simulated canine retraction. An important aspect of this work was to determine whether conventional bracket systems behave differently in passive or active self-ligating brackets used with a Slide™ ligature, an elastic ligature, or a steel ligature.
View Article and Find Full Text PDFObjectives: Bracket material, bracket design, archwire material, and ligature type are critical modifiers of friction behavior during archwire-guided movement of teeth. We designed this in vitro study to compare the friction losses of ceramic injection-molded (CIM) versus pressed-ceramic (PC) and metal injection-molded (MIM) brackets-used with different ligatures and archwires-during archwire-guided retraction of a canine.
Methods: Nine bracket systems were compared, including five CIM (Clarity™ and Clarity™ ADVANCED, both by 3M Unitek; discovery(®) pearl by Dentaurum; Glam by Forestadent; InVu by TP Orthodontics), two PC (Inspire Ice by Ormco; Mystique by DENTSPLY GAC), and two MIM (discovery(®) and discovery(®) smart, both by Dentaurum) systems.
Background: Physical and mental workload during cardiopulmonary resuscitation (CPR) is challenging under extreme working conditions. We hypothesized that the mechanical chest-compression device Lund University Cardiac Assist System (LUCAS) increases the effectiveness of CPR, decreases the physical workload and improves the mental performance of the emergency medical service (EMS) staff during simulated emergency helicopter flights.
Methods: During simulated helicopter flights, 12 EMS teams performed manual or LUCAS-CPR on a manikin at random order.
Peri-implantitis (PI) is characterized by inflammation and bone resorption eventually leading to implant failure, but the characteristic pathologic determinants are undefined to date. This study aims to elucidate the parameters involved in PI pathogenesis, including intraoral implant retention time, extent of bone loss, smoking history, and identification of osteoimmunological markers for inflammation and bone loss. Peri-implant tissues (n = 21) displaying clinically diagnosed PI from patients with vertical bone loss ranging from 0-12 mm and implant function period between 1 and 60 months were evaluated by histochemistry and immunohistochemistry for TRAP, CD3, RANK, RANKL, OPG, and TNF-α.
View Article and Find Full Text PDFBackground And Objective: Gingival invaginations are a frequent finding during tooth extraction and following orthodontic space closure. Based on the interdental localization and sometimes pronounced depth, it has been suggested that a gingival invagination may impede oral hygiene. In Part I of this series, the time until active tooth movement and the localization of extraction were identified as potential risk factors for the development of gingival invagination.
View Article and Find Full Text PDFMany orthodontic treatments involve tooth extraction. Gingival invagination is a common side effect after orthodontic extraction space closure leading to compromised oral hygiene and the space closure being hampered. Even the long-term stability of the orthodontic treatment result may be jeopardized.
View Article and Find Full Text PDF