Background: Portable, smartphone-sized electrocardiography (ECG) has the potential to reduce time to treatment for patients suffering acute cardiac ischemia, thereby lowering the morbidity and mortality. In the UMC Utrecht, a portable, smartphone-sized, multi-lead precordial ECG recording device (miniECG 1.0, UMC Utrecht) was developed.
View Article and Find Full Text PDFBackground: To determine the use of four-dimensional CT as first-line imaging compared to the traditional combination of ultrasound and [Tc]Tc-Sestamibi SPECT.
Materials And Methods: Retrospective review of preoperative imaging in patients with primary hyperparathyroidism, who underwent parathyroidectomy between 2012 and 2021. In one group, the combination ultrasound and [Tc]Tc-Sestamibi SPECT was used as first-line imaging (n = 54), in the other group four-dimensional CT was the first-line imaging modality (n = 51).
Purpose: Follow-up guidelines barely diverge from a one-size-fits-all approach, even though the risk of recurrence differs per patient. However, the personalization of breast cancer care improves outcomes for patients. This study explores the variation in follow-up pathways in the Netherlands using real-world data to determine guideline adherence and the gap between daily practice and risk-based surveillance, to demonstrate the benefits of personalized risk-based surveillance compared with usual care.
View Article and Find Full Text PDFTo investigate flow conditions in a double-layered carotid artery stent, a bench-top in vitro flow setup including a bifurcation phantom was designed and fabricated. The geometry of the tissue-mimicking phantom was based on healthy individuals. Two identical phantoms were created using 3D-printing techniques and molding with PVA-gel.
View Article and Find Full Text PDFBackground: Reliably capturing sub-millimeter vessel wall motion over time, using dynamic Computed Tomography Angiography (4D CTA), might provide insight in biomechanical properties of these vessels. This may improve diagnosis, prognosis, and treatment decision making in vascular pathologies.
Purpose: The aim of this study is to determine the most suitable image reconstruction method for 4D CTA to accurately assess harmonic diameter changes of vessels.
JVS Vasc Sci
September 2023
Objective: The goal of this study was to determine to what extent aortic stent graft motion quantification is comparable between electrocardiogram (ECG)-gated computed tomography (CT) scans with reconstructions into 8 and 10 cardiac phases on CT scanners from two different vendors.
Methods: An experimental setup that induces motion of an aortic stent graft, according to a predefined aortic blood pressure wave, was placed in two CT scanners of different vendors. The stent graft motion was captured using an ECG-gated CT technique and quantified using dedicated analysis algorithms.
Objectives: We sought to investigate if artificial medical images can blend with original ones and whether they adhere to the variable anatomical constraints provided.
Methods: Artificial images were generated with a generative model trained on publicly available standard and low-dose chest CT images (805 scans; 39,803 2D images), of which 17% contained evidence of pathological formations (lung nodules). The test set (90 scans; 5121 2D images) was used to assess if artificial images (512 × 512 primary and control image sets) blended in with original images, using both quantitative metrics and expert opinion.
Objective: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability.
Design: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups.
Cancers (Basel)
August 2023
Unintentional local temperature effects can occur during irreversible electroporation (IRE) treatment, especially near the electrodes, and most frequently near the tip. Partial electrical insulation of the IRE electrodes could possibly control these temperature effects. This study investigated and visualized the effect of partial electrical insulation applied to the IRE electrodes on the electric field line pattern and temperature gradient.
View Article and Find Full Text PDFFour-dimensional computed tomography (4DCT) is one of the preoperative imaging modalities that can be used to localize a parathyroid adenoma in primary hyperparathyroidism patients however, sensitivity differs in literature and could be improved especially for multiglandular hyperplasia or double adenomas. The most robust feature on the 4DCT for the differentiation between parathyroid adenoma and thyroid gland tissue is arterial enhancement. To make this better visible, we have developed a subtraction map that shows arterial enhancement as a color scale to increase sensitivity for 4DCT.
View Article and Find Full Text PDFPurpose: 4D Transperineal ultrasound (TPUS) is used to examine female pelvic floor disorders. Muscle movement, like performing a muscle contraction or a Valsalva maneuver, can be captured on TPUS. Our work investigates the possibility for unsupervised analysis and classification of the TPUS data.
View Article and Find Full Text PDFTo what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE).
View Article and Find Full Text PDFThe aim of this study was to review the effect of irreversible electroporation parameter settings on the size of the ablation zone and the occurrence of thermal effects. This insight would help to optimize treatment protocols and effectively ablate a tumor while controlling the occurrence of thermal effects. Various individual studies report the influence of variation in electroporation parameters on the ablation zone size or occurrence of thermal effects.
View Article and Find Full Text PDFPurpose: Visual assessment of Rubidium (Rb-82) PET myocardial perfusion images is usually combined with global myocardial flow reserve (MFR) measurements. However, small regional blood flow deficits may go unnoticed. Our aim was to compare the diagnostic value of regional with global MFR in the detection of obstructive coronary artery disease (oCAD).
View Article and Find Full Text PDFBioengineering (Basel)
September 2022
This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions.
View Article and Find Full Text PDFObjectives: Based on germline and somatic mutation profiles, pheochromocytomas and paragangliomas (PPGLs) can be classified into different clusters. We investigated the use of [F]FDG-PET/CT radiomics, SUV and biochemical profile for the identification of the genetic clusters of PPGLs.
Methods: In this single-centre cohort, 40 PPGLs (13 cluster 1, 18 cluster 2, 9 sporadic) were delineated using a 41% adaptive threshold of SUV ([F]FDG-PET) and manually (low-dose CT; ldCT).
Purpose: Thromboembolic events (TE), including limb graft occlusion (LGO) and distal limb embolization (DLE), are common complications after endovascular aneurysm repair (EVAR). The aim of this study was to find predictors for TE in patients treated with the Anaconda stent-graft for infrarenal aneurysms.
Materials And Methods: Geometrical and anatomical variables were retrospectively analyzed in a consecutive Anaconda cohort.
Semin Thorac Cardiovasc Surg
June 2022
Patients suffering from pectus excavatum often experience psychosocial distress due to perceived anomalies in their physical appearance. The ability to visually inform patients about their expected aesthetic outcome after surgical correction is still lacking. This study aims to develop an automatic, patient-specific model to predict aesthetic outcome after the Nuss procedure.
View Article and Find Full Text PDFBackground: Absolute myocardial perfusion imaging (MPI) is beneficial in the diagnosis and prognosis of patients with suspected or known coronary artery disease. However, validation and standardization of perfusion estimates across centers is needed to ensure safe and adequate integration into the clinical workflow. Physical myocardial perfusion models can contribute to this clinical need as these can provide ground-truth validation of perfusion estimates in a simplified, though controlled setup.
View Article and Find Full Text PDFThe RelayBranch stent-graft (Terumo Aortic, Sunrise, FL, USA) offers a custom-made endovascular solution for complex aortic arch pathologies. In this technical note, a modified electrocardiography (ECG)-gated computed tomography (CT)-based algorithm was applied to quantify cardiac-pulsatility-induced changes of the aortic arch geometry and motion before and after double-branched endovascular repair (bTEVAR) of an aortic arch aneurysm. This software algorithm has the potential to provide novel and clinically relevant insights in the influence of bTEVAR on aortic anatomy, arterial compliance, and stent-graft dynamics.
View Article and Find Full Text PDFBackground And Purpose: To apply and evaluate an intensity-based interpolation technique, enabling segmentation of motion-affected neonatal brain MRI.
Methods: Moderate-late preterm infants were enrolled in a prospective cohort study (Brain Imaging in Moderate-late Preterm infants "BIMP-study") between August 2017 and November 2019. T2-weighted MRI was performed around term equivalent age on a 3T MRI.
Objectives: This study aimed to systematically review recent health economic evaluations (HEEs) of artificial intelligence (AI) applications in healthcare. The aim was to discuss pertinent methods, reporting quality and challenges for future implementation of AI in healthcare, and additionally advise future HEEs.
Methods: A systematic literature review was conducted in 2 databases (PubMed and Scopus) for articles published in the last 5 years.
Purpose: Changes in the flared end of balloon-expandable covered stent (BECS) may precede BECS-associated complications but are not regularly assessed with computed tomographic angiography (CTA) after fenestrated endovascular aneurysm repair (FEVAR). Validation of the flare geometric analysis (FGA) and assessment of intraobserver and interobserver variability are investigated in this study.
Methods: Two series of 3 BeGraft BECSs (Bentley InnoMed GmbH, Hechingen, Germany) and 1 series of 3 Advanta V12 BECSs (Getinge AB, Göteborg, Sweden) were deployed in 3 side branches (45°, 60°, and 90° aortic branch angles) of an aorta phantom model.