A residual false lumen after treatment for Aortic Dissection type A (AD) has been associated with early complications, such as A malperfusion or rupture and mid-term or delayed complications, such as aneurysm formation or dissection expansion. Thoracic Endovascular Aortic Repair (TEVAR) is considered an effective solution by several surgical teams to prevent future complications. In this systematic review, all published data regarding the implementation of TEVAR after previous treatment for AD were collected in order to investigate indications, methods, clinical outcomes and aortic remodeling in these patients.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
September 2024
Objective: To assess the comparative safety and efficacy of covered stents (CS) and bare metal stents (BMS) in the endovascular treatment of aorto-iliac disease in patients with peripheral arterial disease.
Data Sources: A systematic review was conducted adhering to the PRISMA 2020 and PRISMA for Individual Participant Data 2015 guidelines.
Review Methods: A search of PubMed, Scopus, and Web of Science for articles published by December 2023 was performed.
Objective: Late rupture after endovascular aortic aneurysm repair (EVAR) for an abdominal aortic aneurysm (AAA) is an increasing complication associated with a high mortality rate. This study aimed to analyse the causes and outcomes in patients with AAA rupture after EVAR.
Methods: A multi-institutional Greek study of late ruptures after EVAR between 2008 - 2022 was performed.
Objective: This study aimed to investigate the correlation between aneurysm sac behaviour and time to re-intervention after endovascular aneurysm repair (EVAR).
Methods: A retrospective observational cohort study of patients who underwent EVAR at a single centre between January 2008 and November 2011 and who were followed up for a mean of 6.6 ± 2.
Background: Venous leg ulcer (VLU) disease constitutes the most severe form of chronic venous insufficiency. We performed a network meta-analysis and meta-regression to investigate the efficacy and safety of the various available interventions in the treatment of VLU.
Methods: We conducted a systematic research corresponding to the instructions by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement for studies reporting on surgical or endovenous interventions for the treatment of VLU.
Background: Endovascular aortic repair (EVAR) has conferred an early survival advantage compared to an open surgical repair (OSR) in patients with ruptured abdominal aortic aneurysms (rAAA). However, the long-term survival benefit after EVAR was not displayed among randomized controlled trials (RCTs), whereas many non-RCTs have provided conflicting results. We conducted a time-to-event individual patient data (IPD) meta-analysis on long-term rAAA data.
View Article and Find Full Text PDFObjectives: A remarkable increase in the number of patients presenting with tracheal complications after prolonged endotracheal intubation and mechanical ventilation for the management of the severe COVID-19-associated respiratory failure has been observed. In this study, we assessed the postoperative outcomes of tracheal resection in patients with COVID-19.
Methods: We conducted a retrospective study in which all patients with a history of prolonged invasive mechanical ventilation due to COVID-19 infection, who were treated with tracheal resection and reconstruction, were included.
Background: Coarctation of the aorta (CoA) is a congenital cardiovascular malformation involving narrowing of the thoracic aorta just distal to the left subclavian artery. The aim of our study was to evaluate the hemodynamic effects of endovascular treatment for CoA by using invasive aortic catheterization.
Methods: All patients with CoA who underwent treatment by aortic stent implantation between September 1, 2003, and February 1, 2019, at the "Onassis Cardiac Surgery Center," in Athens, Greece, were evaluated.
Introduction: The aim of this study was to compare mean maximum ascending aortic diameter at the time of acute aortic dissection with the current surgical threshold for elective ascending aortic operations on non-syndromic thoracic aortic aneurysms.
Material And Methods: All consecutive non-syndromic adult patients admitted for acute type A aortic dissection in a single tertiary centre were prospectively enrolled from April 2020 to March 2021. The primary endpoint was the difference between mean maximum aortic diameter at the time of dissection and the 5.
Objective: To assess the efficacy and safety of carotid artery stenting for the treatment of extracranial carotid artery dissection (CAD).
Data Sources: Systematic review using Medline, Scopus, EMBASE, and the Cochrane Library.
Review Methods: A systematic search was performed according to the Preferred Reporting Items for Systematic reviews and Meta-analysis statement.
J Clin Med
June 2022
This study aims to assess the role of Color Duplex Ultrasound with or without contrast media for surveillance following endovascular aortic aneurysm repair (EVAR). A systematic search of the literature published until April 2022 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The pooled rates of endoleak detection through Contrast-Enhanced or Color Duplex Ultrasound (CEUS or CDUS) and Computed Tomography Angiography (CTA) with 95% confidence intervals (CIs) were estimated using random-effect analysis.
View Article and Find Full Text PDFObjective: To synthesise and present all available evidence regarding the surgical treatment of patients with aberrant subclavian artery (aSA) pathologies during the last 30 years. The study also aimed to create a checklist of suggested reporting items to help increase reporting homogeneity.
Methods: A systematic search of medical databases was performed to identify all studies published between 1990 and 2020 reporting on the outcomes of patients undergoing surgery for an aSA pathology.
Background: The ever-changing landscape of aortic arch surgery necessitates a constant update on the available devices and technologies for the contemporary management of complex aortic diseases. The E-Vita OPEN NEO hybrid stent graft system offers a unique approach for aortic arch replacement with the frozen elephant trunk technique. In contrast to its predecessors and other commercially available devices, it fits to each individual patient's needs by allowing for more proximal graft anastomosis.
View Article and Find Full Text PDFJ Vasc Surg
July 2022
Objective: We performed a systematic review and meta-analysis to assess the stroke rates after thoracic endovascular aortic repair (TEVAR) for descending thoracic aortic aneurysms and/or dissections.
Methods: A systematic search of all the literature reported until September 2021 was performed according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines. The pooled perioperative stroke rates and corresponding 95% confidence intervals (CIs) were estimated using fixed or random effect methods.
Introduction: Stenting of infrainguinal lesions can be rather challenging due to the mechanical stress applied on the arteries during motion. We assessed the short-term and mid-term safety and efficacy of Supera interwoven nitinol stent for the treatment of infrainguinal arterial disease.
Evidence Acquisition: We conducted a systematic review for articles published from December 2011 up to May 2021 regarding studies assessing the safety and efficacy of Supera interwoven nitinol stents for the treatment of infra-inguinal peripheral arterial disease.
Background: DFU (diabetic foot ulcer) represents a major global health and socioeconomic problem and a leading cause of lower limb amputation. Although many therapies have been tested, none has been proposed as a dominant wound healing treatment. We performed a prospective randomized controlled study in order to assess the role of autologous platelet rich plasma (PRP) for the promotion of non-ischemic DFU healing.
View Article and Find Full Text PDFSimultaneous EVAR and TAVR is technically feasible and is a reliable option in high-risk patients.
View Article and Find Full Text PDFImplantable cardioverter-defibrillators (ICDs) remain the standard of care in advanced heart failure with reduced ejection fraction patients for the prevention of sudden cardiac death. However, current guidelines remain conflicting with respect to the use of ICDs in patients supported with a continuous flow left ventricular assist device (CF-LVAD). The current review adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
View Article and Find Full Text PDFVascular
June 2022
Objectives: To collect and analyse the available evidence in the outcomes of patients treated with fenestrated endovascular aortic repair (f-EVAR) technique focusing specifically on visceral vessel outcomes.
Methods: The current meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All the studies reporting the f-EVAR technique for the management of degenerative pararenal and/or type IV thoracoabdominal aortic aneurysms (TAAA) were considered eligible for inclusion in the study.
Objective: We evaluated the safety and efficacy of multilayer flow modulator (MFM) stents (Cardiatis, Isnes, Belgium) for the treatment of complex aortic lesions.
Methods: A systematic electronic research was conducted for studies reported from December 2008 to May 2020. Data extracted from 15 eligible case series (CS) were appropriately pooled and analyzed in a meta-analysis.
Objective: Morbidity and mortality in patients experiencing the rupture of intracranial aneurysm ruptures are high. We conducted a systematic review and meta-analysis to investigate the role of stent-assisted coiling (SAC) for unruptured intracranial aneurysms (UIAs) with wide neck.
Materials And Methods: The current meta-analysis was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.