Publications by authors named "Connolley T"

Understanding the correlation between chemical and microstructural properties is critical for unraveling the fundamental relationship between materials chemistry and physical structures that can benefit materials science and engineering. Here, we demonstrate novel in situ correlative imaging of the X-ray Compton scattering computed tomography (XCS-CT) technique for studying this fundamental relationship. XCS-CT can image light elements that do not usually exhibit strong signals using other X-ray characterization techniques.

View Article and Find Full Text PDF

Three-dimensional X-ray diffraction (3DXRD) is shown to be feasible at the I12 Joint Engineering, Environmental and Processing (JEEP) beamline of Diamond Light Source. As a demonstration, a microstructually simple low-carbon ferritic steel was studied in a highly textured and annealed state. A processing pipeline suited to this beamline was created, using software already established in the 3DXRD user community, enabling grain centre-of-mass positions, orientations and strain tensor elements to be determined.

View Article and Find Full Text PDF

The performance of Li ion batteries (LIBs) is hindered by steep Li ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li ion concentration gradient problem is exacerbated. Most understanding of Li ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li.

View Article and Find Full Text PDF

Experimental and field studies reported a significant discrepancy between the cleanup and contamination time scales, while its cause is not yet addressed. Using high-resolution fast synchrotron x-ray computed tomography, we characterized the solute transport in a fully saturated sand packing for both contamination and cleanup processes at similar hydrodynamic conditions. The discrepancy in the time scales has been demonstrated by the nonuniqueness of hydrodynamic dispersion coefficient versus injection rate (Péclet number).

View Article and Find Full Text PDF

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion.

View Article and Find Full Text PDF

Numerous aspects of early hominin biology remain debated or simply unknown. However, recent developments in high-resolution imaging techniques have opened new avenues in the field of paleoanthropology. More specifically, X-ray synchrotron-based analytical imaging techniques have the potential to provide crucial details on the ontogeny, physiology, biomechanics, and biological identity of fossil specimens.

View Article and Find Full Text PDF

An experimental technique is described for the collection of time-resolved X-ray diffraction information from a complete commercial battery cell during discharging or charging cycles. The technique uses an 80 × 80 pixel 2D energy-discriminating detector in a pinhole camera geometry which can be used with a polychromatic X-ray source. The concept was proved in a synchrotron X-ray study of commercial alkaline Zn-MnO AA size cells.

View Article and Find Full Text PDF

As a part of a research into new techniques for purifying recycled aluminium alloys, a novel electromagnetic apparatus had been developed for investigating in real-time the separation mechanisms of detrimental inclusions in aluminium alloy melts under alternating magnetic fields. The magnetic coil was designed based on the Helmholtz coil design. A viewing gap was designed for imaging studies using synchrotron X-rays.

View Article and Find Full Text PDF

Quantitative understanding of the interactions of ultrasonic waves with liquid and solidifying metals is essential for developing optimal processing strategies for ultrasound processing of metal alloys in the solidification processes. In this research, we used the synchrotron X-ray high-speed imaging facility at Beamline I12 of the Diamond Light Source, UK to study the dynamics of ultrasonic bubbles in a liquid Sn-30wt%Cu alloy. A new method based on the X-ray attenuation for a white X-ray beam was developed to extract quantitative information about the bubble clouds in the chaotic and quasi-static cavitation regions.

View Article and Find Full Text PDF

Internal flow behaviour during melt-pool-based metal manufacturing remains unclear and hinders progression to process optimisation. In this contribution, we present direct time-resolved imaging of melt pool flow dynamics from a high-energy synchrotron radiation experiment. We track internal flow streams during arc welding of steel and measure instantaneous flow velocities ranging from 0.

View Article and Find Full Text PDF

The high flux of the white X-ray beams from third-generation synchrotron light sources can significantly benefit the development of high-speed X-ray imaging, but can also bring technical challenges to existing X-ray imaging systems. One prevalent problem is that the image quality deteriorates because of dust particles accumulating on the scintillator screen during exposure to intense X-ray radiation. Here, this problem has been solved by embedding the scintillator in a flowing inert-gas environment.

View Article and Find Full Text PDF

The data presented in this article are related to the paper entitled 'Ultrafast synchrotron X-ray imaging studies of microstructure fragmentation in solidification under ultrasound' [Wang et al., Acta Mater. 144 (2018) 505-515].

View Article and Find Full Text PDF

The cavitation-induced fragmentation of primary crystals formed in Al alloys were investigated for the first time by high-speed imaging using a novel experimental approach. Three representative primary crystal types, AlTi, Si and AlV with different morphologies and mechanical properties were first extracted by deep etching of the corresponding Al alloys and then subjected to ultrasonic cavitation processing in distilled water. The dynamic interaction between the cavitation bubbles and primary crystals was imaged in situ and in real time.

View Article and Find Full Text PDF

This paper discusses the possibility of using Compton scattering--an inelastic X-ray scattering process that yields a projection of the electron momentum density--to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO3.

View Article and Find Full Text PDF

A new synchrotron-based technique for elemental imaging that combines radiography and fluorescence spectroscopy has been developed and applied to study the spatial distribution of Ag, Zr and Mo in an Al alloy during heating and melting to 700, and then re-soldification. For the first time, multi-element distributions have been mapped independently and simultaneously, showing the dissolution of Ag- and Zr-rich particles during melting and the inter-dendritic segregation of Ag during re-solidification. The new technique is shown to have wide potential for metallurgical and materials science applications where the dynamics of elemental re-distribution and segregation in complex alloys is of importance.

View Article and Find Full Text PDF

Grain refinement via semi-solid deformation is desired to obtain superior mechanical properties of cast components. Using quantitative in situ synchrotron X-ray tomographic microscopy, we show an additional mechanism for the reduction of grain size, via liquation assisted transgranular cracking of semi-solid globular microstructures. Here we perform localized indentation of Al-15wt.

View Article and Find Full Text PDF

I12 is the Joint Engineering, Environmental and Processing (JEEP) beamline, constructed during Phase II of the Diamond Light Source. I12 is located on a short (5 m) straight section of the Diamond storage ring and uses a 4.2 T superconducting wiggler to provide polychromatic and monochromatic X-rays in the energy range 50-150 keV.

View Article and Find Full Text PDF

The behaviour of granular solid-liquid mixtures is key when deforming a wide range of materials from cornstarch slurries to soils, rock and magma flows. Here we demonstrate that treating semi-solid alloys as a granular fluid is critical to understanding flow behaviour and defect formation during casting. Using synchrotron X-ray tomography, we directly measure the discrete grain response during uniaxial compression.

View Article and Find Full Text PDF

In recent times, there has been a drive to develop non-destructive X-ray imaging techniques that provide chemical or physical insight. To date, these methods have generally been limited; either requiring raster scanning of pencil beams, using narrow bandwidth radiation and/or limited to small samples. We have developed a novel full-field radiographic imaging technique that enables the entire physio-chemical state of an object to be imaged in a single snapshot.

View Article and Find Full Text PDF

A complete calibration method to characterize a static planar two-dimensional detector for use in X-ray diffraction at an arbitrary wavelength is described. This method is based upon geometry describing the point of intersection between a cone's axis and its elliptical conic section. This point of intersection is neither the ellipse centre nor one of the ellipse focal points, but some other point which lies in between.

View Article and Find Full Text PDF

The focus in macromolecular crystallography is moving towards even more challenging target proteins that often crystallize on much smaller scales and are frequently mounted in opaque or highly refractive materials. It is therefore essential that X-ray beamline technology develops in parallel to accommodate such difficult samples. In this paper, the use of X-ray microradiography and microtomography is reported as a tool for crystal visualization, location and characterization on the macromolecular crystallography beamlines at the Diamond Light Source.

View Article and Find Full Text PDF

The present investigation establishes the feasibility of using synchrotron-generated X-ray beams for time-resolved in situ imaging and diffraction of the interior components of an internal combustion engine during its operation. The demonstration experiment was carried out on beamline I12 (JEEP) at Diamond Light Source, UK. The external hutch of the JEEP instrument is a large-scale engineering test bed for complex in situ processing and simulation experiments.

View Article and Find Full Text PDF

There are many cases where it is desirable to reconstruct at high resolution a small volume from a larger sample. Here we describe the outcomes of a reconstruction trial based on real samples aimed at delineating the practical limits to which a small region of interest can be viewed from a large sample. Our approach has been to artificially truncate the sinograms of whole sample scans to simulate region of interest tomography.

View Article and Find Full Text PDF
Article Synopsis
  • Engineers often use finite-element analysis to assess how single crystals deform under bending or thermal loads at synchrotron beamlines.
  • ANSYS Workbench is a popular software choice for these simulations, providing insights into displacements, strains, and stresses.
  • A new method has been developed to extract local reciprocal lattice vectors for X-ray diffraction calculations, applied to a specific double-crystal monochromator project at the Diamond Light Source.
View Article and Find Full Text PDF

Cardiovascular stents are commonly made from 316L stainless steel and are deployed within stenosed arterial lesions using balloon expansion. Deployment involves inflating the balloon and plastically deforming the stent until the required diameter is obtained. This plastic deformation induces static stresses in the stent, which will remain for the lifetime of the device.

View Article and Find Full Text PDF