Publications by authors named "Colin Hastie"

An automated method for the measurement of blood tacrolimus on volumetric absorptive microsampling (VAMS) devices was developed. VAMS devices prepared by the automated method were compared with those prepared by the existing manual method (n = 284; mean concentration: 8.0 μg/l; range: 0.

View Article and Find Full Text PDF

Genotoxicity testing methods in vitro provide a means to predict the DNA damaging effects of chemicals on human cells. This is hindered in the case of hydrophobic test compounds, however, which will partition to in vitro components such as plastic-ware and medium proteins, in preference to the aqueous phase of the exposure medium. This affects the freely available test chemical concentration, and as this freely dissolved aqueous concentration is that bioavailable to cells, it is important to define and maintain this exposure.

View Article and Find Full Text PDF

Cyclic volatile methylsiloxanes (cVMS) are used in personal care products and are hydrophobic, volatile and persistent. Their environmental water concentrations are low and are difficult to detect using conventional sampling methods. This study shows the potential of passive sampling for cVMS.

View Article and Find Full Text PDF

Monitoring of cyclic volatile methylsiloxanes (cVMS) carried out at Anglian Water's Broadholme sewage treatment plant (STP) is described. The method deployed used headspace gas chromatography/mass spectrometry (HS-GC/MS) and the addition of isotopically labelled cVMS to correct for partitioning in samples containing high levels of particulate and dissolved organic carbon. The method was capable of measuring cVMS in raw sewage samples, with recoveries of 80%, 85% and 71% respectively, for D4, D5 and D6.

View Article and Find Full Text PDF

The cyclic volatile methylsiloxane, decamethylcyclopentasiloxane (D5) is used in a large variety of personal care products. Based on the physical-chemical properties of D5, it is likely that losses due to volatilisation may strongly influence the levels entering the aquatic environment. The aim of this study was to quantify the amount of D5 in waste wash water, after typical application and use in a range of deodorant and anti-perspirant (AP) products.

View Article and Find Full Text PDF

Robust analytical procedures for the measurement of decamethylcyclopentasiloxane (D₅) in river and estuarine sediments and their application in determining environmental concentrations in the UK are presented for the first time in this work. Novel approaches to minimise commonly reported artefacts are utilised, improving the confidence in the concentrations of D₅ reported. Accelerated solvent extraction (ASE) and liquid-solid extraction methods are compared.

View Article and Find Full Text PDF

A method is described for the analysis of decamethylcyclopentasiloxane (D(5)) in river water and treated waste water using headspace gas chromatography/mass spectrometry. Internal standard addition to samples and field blanks was carried out in the field to provide both a measure of recovery and to prevent any exposure of samples to laboratory air, which contained background levels of D(5). Measured levels of D(5) were typically in the range <10-29ngL(-1) in the River Great Ouse (UK) with slightly higher levels in the River Nene (UK).

View Article and Find Full Text PDF