Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5-2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials.
View Article and Find Full Text PDFJ Synchrotron Radiat
September 2022
The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick-Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution.
View Article and Find Full Text PDFThe aims of this study were to investigate the clinical effectiveness and patient acceptability of a modified glass ionomer cement placed using the atraumatic restorative treatment (ART) technique to treat root caries, and to carry out microbiological analysis of the restored sites. Two clinically visible root surface carious lesions per participant were restored using ART. One was restored with commercial glass ionomer cement (GIC) (ChemFil Superior, DENTSPLY, Konstonz, Germany) which acted as the control.
View Article and Find Full Text PDFA transmission X-ray microscope has been designed and commissioned at the 18-ID Full-field X-ray Imaging beamline at the National Synchrotron Light Source II. This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view of about 40 μm. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under 1 min.
View Article and Find Full Text PDFDetermination of the sludge volume index is key to describing the settling characteristics of sludge in the aeration process of wastewater treatment plants (WWTPs). The two core components of this calculation are the settled sludge volume (SSV) and suspended solids. While the measurement procedure for SSV is generally defined by national or international standards, in practice a wide variety of vessel sizes and shapes are used by operators to monitor WWTP performance.
View Article and Find Full Text PDFWastewater treatment facilities are continually challenged to meet both environmental regulations and reduce running costs (particularly energy and staffing costs). Improving the efficiency of operational monitoring at wastewater treatment plants (WWTPs) requires the development and implementation of appropriate performance metrics; particularly those that are easily measured, strongly correlate to WWTP performance, and can be easily automated, with a minimal amount of maintenance or intervention by human operators. Turbidity is the measure of the relative clarity of a fluid.
View Article and Find Full Text PDFSynchrotron Radiat News
September 2018
The L-shaped laterally graded multilayer mirror is a vital part of the ultrahigh-energy and momentum-resolution inelastic X-ray scattering spectrometer at the National Synchrotron Light Source II. This mirror was designed and implemented as a two-dimensional collimating optic for the analyzer system. Its performance was characterized using a secondary large-divergence source at the 30-ID beamline of the Advanced Photon Source, which yielded an integrated reflectivity of 47% and a collimated beam divergence of 78 µrad with a source size of 10 µm.
View Article and Find Full Text PDFWe demonstrate that a novel actuation scheme, employed in an optical control deformable mirror, can be more convenient than the conventional discrete fixed actuators approach. The Photo-Controlled Deformable Mirror (PCDM) mirror leverages consumer LCD display technology in the wavefront forming control, enabling flexible programmable configuration of the actuation geometry. This new approach simplifies the driving electronics, relaxing the per channel cost of high spatial control of the wavefront forming surface.
View Article and Find Full Text PDFWe have studied the effects of multiple-wave diffraction in a novel optical scheme recently published by Shvyd'ko et al. utilizing Bragg diffraction of x rays in backscattering geometry from asymmetrically cut crystals for achieving energy resolutions beyond the intrinsic width of the Bragg reflection. By numerical simulations based on dynamic x-ray diffraction and by experimentation involving two-dimensional angular scans of the back-reflecting crystal, multiple-wave diffraction was found to contribute up to several tens percent loss of efficiency but can be avoided without degrading the energy resolution of the original scheme by careful choice of azimuthal orientation of the diffracting crystal surface and by tilting of the crystal perpendicular to the dispersion plane.
View Article and Find Full Text PDFCharacterization and testing of an L-shaped laterally graded multilayer mirror are presented. This mirror is designed as a two-dimensional collimating optics for the analyzer system of the ultra-high-resolution inelastic X-ray scattering (IXS) spectrometer at National Synchrotron Light Source II (NSLS-II). The characterization includes point-to-point reflectivity measurements, lattice parameter determination and mirror metrology (figure, slope error and roughness).
View Article and Find Full Text PDFSequence preferences of DNA binding proteins are a primary mechanism by which cells interpret the genome. Despite the central importance of these proteins in physiology, development, and evolution, comprehensive DNA binding specificities have been determined experimentally for only a few proteins. Here, we used microarrays containing all 10-base pair sequences to examine the binding specificities of 104 distinct mouse DNA binding proteins representing 22 structural classes.
View Article and Find Full Text PDFThe sequence specificity of DNA-binding proteins is the primary mechanism by which the cell recognizes genomic features. Here, we describe systematic determination of yeast transcription factor DNA-binding specificities. We obtained binding specificities for 112 DNA-binding proteins representing 19 distinct structural classes.
View Article and Find Full Text PDFThe main applications of adaptive optics are the correction of the effects of atmospheric turbulence on ground-based telescopes and the correction of ocular aberrations in retinal imaging and visual simulation. The requirements for the wavefront corrector, usually a deformable mirror, will depend on the statistics of the aberrations to be corrected; here we compare the spatial statistics of wavefront aberrations expected in these two applications. We also use measured influence functions and numerical simulations to compare the performance of eight commercially available deformable mirrors for these tasks.
View Article and Find Full Text PDFJ Synchrotron Radiat
July 2007
Soc Sci Med
January 2004
This paper describes and critiques the income inequality approach to health inequalities. It then presents an alternative class-based model through a focus on the causes and not only the consequences of income inequalities. In this model, the relationship between income inequality and health appears as a special case within a broader causal chain.
View Article and Find Full Text PDFAn internationally influential model of population health was developed in Canada in the 1990s, shifting the research agenda beyond health care to the social and economic determinants of health. While agreeing that health has important social determinants, the authors believe that this model has serious shortcomings; they critique the model by focusing on its hidden assumptions. Assumptions about how knowledge is produced and an implicit interest group perspective exclude the sociopolitical and class contexts that shape interest group power and citizen health.
View Article and Find Full Text PDFBr J Oral Maxillofac Surg
June 2002
A dedicated bicortical bone screw for temporary intraoperative intermaxillary fixation (IMF) during open reduction and fixation of mandibular fractures offers many benefits to surgeons and patients. We have used this system for 2 years and confirm the benefits over traditional methods of intermaxillary fixation. However, complications can arise.
View Article and Find Full Text PDFThere has been a recent upsurge of interest in the relationship between income inequality and health within nations and between nations. On the latter topic Wilkinson and others believe that, in the advanced capitalist countries, higher income inequality leads to lowered social cohesion which in turn produces poorer health status. I argue that, despite a by-now voluminous literature, not enough attention has been paid to the social context of income inequality--health relationships or to the causes of income inequality itself.
View Article and Find Full Text PDF