Publications by authors named "Clyde J Smith"

Near infrared spectroscopy is routinely used in the noninvasive monitoring of cerebral and somatic regional oxygen saturation (rSO) in pediatric patients following surgery for congenital heart disease. We sought to evaluate the association of a bedside rSO thought algorithm with clinical outcomes in a cohort of pediatric patients following cardiac surgery. This was a single-center retrospective cohort study of patients admitted following cardiac surgery over a 42-month period.

View Article and Find Full Text PDF

Introduction: Neonates and infants who undergo congenital cardiac surgery frequently have difficulty with feeding. The factors that predispose these patients to require a gastrostomy tube have not been well defined. We aimed to report the incidence and describe hospital outcomes and characteristics in neonates and infants undergoing congenital cardiac surgery who required gastrostomy tube placement.

View Article and Find Full Text PDF

Background: Electroencephalographic seizures (ESs) after neonatal cardiac surgery are often subclinical and have been associated with poor outcomes. An accurate ES prediction model could allow targeted continuous electroencephalographic monitoring (CEEG) for high-risk neonates.

Methods: ES prediction models were developed and validated in a multicenter prospective cohort where all postoperative neonates who underwent cardiopulmonary bypass (CPB) also underwent CEEG.

View Article and Find Full Text PDF

There is a shortage of pediatric donor hearts for waitlisted children, and yet nearly 50% of organs offered are not transplanted. Donor quality is often cited as a reason for declining organs offered from donors infected with influenza, presumably due to concern about disease transmission at transplant leading to severe disease. We previously described an excellent outcome after heart transplant from a donor infected with influenza B that had been treated with a complete course of oseltamivir.

View Article and Find Full Text PDF

: In practice, asthma control is assessed according to symptom burden and office spirometry. However, spirometry poorly tests peripheral lung function, which may be abnormal in asthma. Impluse oscillometry (IOS) and multiple-breath washout (MBW) are novel methods which measure reactance (X5) and ventilation heterogeneity (VH) in the peripheral lung, but how well these tests reflect asthma control is poorly understood.

View Article and Find Full Text PDF

As heart transplantation demand is increasing without subsequent growth of the donor pool, need for expansion of acceptance criteria is paramount, particularly when considering critically ill, highly sensitized patients. We present a case report of a pediatric heart transplant recipient of an organ refused by 197 prior potential recipients due to the donor being infected with influenza virus. We perform a literature review of recent solid organ transplant cases from influenza-positive donors and conclude that the donor pool may be expandable by allowing donors with treatable infections to be included.

View Article and Find Full Text PDF