The East Antarctic Ice Sheet (EAIS) has its origins ca. 34 million years ago. Since then, the impact of climate change and past fluctuations in the EAIS margin has been reflected in periods of extensive vs.
View Article and Find Full Text PDFMountain uplift and erosion have regulated the balance of carbon between Earth's interior and atmosphere, where prior focus has been placed on the role of silicate mineral weathering in CO drawdown and its contribution to the stability of Earth's climate in a habitable state. However, weathering can also release CO as rock organic carbon (OC) is oxidized at the near surface; this important geological CO flux has remained poorly constrained. We use the trace element rhenium in combination with a spatial extrapolation model to quantify this flux across global river catchments.
View Article and Find Full Text PDFShape-memory polymer (SMP) polyurethane foams have been applied as embolic devices and implanted in multiple animal models. These materials are oxidatively degradable and it is critical to quantify and characterize the degradation for biocompatibility assessments. An image-based method using high-resolution and magnification scans of histology sections was used to estimate the mass loss of the peripheral and neurovascular embolization devices (PED, NED).
View Article and Find Full Text PDFIn this report, we showcase diffusible iodine-based contrast-enhanced computed tomography (DICE-CT) as a method for improving soft tissue visualization and reducing beam hardening artifact within a stented vessel. This technique is commonly used in our pathology lab to image soft tissue specimens with dense metal implants and to ensure reliable morphological analysis through clear delineation of tissue structures. For this report, a porcine right coronary artery with an implanted metal stent was scanned using both conventional and DICE-CT methods.
View Article and Find Full Text PDFHost response to an implanted biomaterial is a complex process involving microscopic changes in extracellular matrix (ECM) composition. Reliable pathology analysis is imperative for accurate assessment of the tissue response to an implanted device. Plastic histology is commonly used for histology evaluation of medical devices to assess the device-tissue interface; however, this technique is prone to variable staining that can confound histology interpretation.
View Article and Find Full Text PDFThe IMPEDE Embolization Plug is a catheter-delivered vascular occlusion device that utilizes a porous shape memory polymer foam as a scaffold for thrombus formation and distal coils to anchor the device within the vessel. In this study, we investigated the biological response of porcine arteries to the IMPEDE device by assessing the extent of healing and overall effectiveness in occluding the vessel at 30, 60, and 90 days. Compared to control devices (Amplatzer Vascular Plug and Nester Embolization Coils), the host response to IMPEDE showed increased cellular infiltration (accommodated by the foam scaffold), which led to advanced healing of the initial thrombus to mature collagenous connective tissue (confirmed by transmission electron microscopy (TEM)).
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
July 2020
Recent studies utilizing shape memory polymer foams to coat embolizing coils have shown potential benefits over current aneurysm treatments. In the current study utilizing a rabbit-elastase aneurysm model, the performance of test article (foam-coated coil [FCC]) and control (bare platinum coils [BPCs]) devices were compared at 30, 90, and 180 days using micro-CT and histological assessments. The host response was measured by identifying the cells regionally present within the aneurysm, and assessing the degree of residual debris and connective tissue.
View Article and Find Full Text PDFLong-term, subcutaneously implanted continuous glucose biosensors have the potential to improve diabetes management and reduce associated complications. However, the innate foreign body reaction (FBR) both alters the local glucose concentrations in the surrounding tissues and compromises glucose diffusion to the biosensor due to the recruitment of high-metabolizing inflammatory cells and the formation of a dense, collagenous fibrous capsule. Minimizing the FBR has mainly focused on "passively antifouling" materials that reduce initial cellular attachment, including poly(ethylene glycol) (PEG).
View Article and Find Full Text PDFPathologic evaluation is crucial to the study of medical devices and integral to the Food and Drug Administration and other regulatory entities' assessment of device safety and efficacy. While pathologic analysis is tailored to the type of device, it generally involves at a minimum gross and microscopic evaluation of the medical device and associated tissues. Due to the complex nature of some implanted devices and specific questions posed by sponsors, pathologic evaluation inherently presents many challenges in accurately assessing medical device safety and efficacy.
View Article and Find Full Text PDFUnlabelled: Cardiovascular implantable electronic devices (CIEDs) typically incorporate leads that directly contact the endocardium. Post-explant pathology evaluation of formalin-fixed CIED lead implant sites and downstream organs (i.e.
View Article and Find Full Text PDFTowards achieveing a subcutaneously implanted glucose biosensor with long-term functionality, a thermoresponsive membrane previously shown to have potential to house a glucose sensing assay was evaluated herein for its ability to minimize the foriegn body reaction (FBR) and the resulting fibrous capsule. The severity of the FBR proportionally reduces diffusion of glucose to the sensor and hence sensor lifetime. However, efforts to reduce the FBR have largedly focused on anti-fouling materials that passively inhibit cellular attachment, particularly poly(ethylene glycol) (PEG).
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
October 2016
Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
October 2017
The endovascular delivery of platinum alloy bare metal coils has been widely adapted to treat intracranial aneurysms. Despite the widespread clinical use of this technique, numerous suboptimal outcomes are possible. These may include chronic inflammation, low volume filling, coil compaction, and recanalization, all of which can lead to aneurysm recurrence, need for retreatment, and/or potential rupture.
View Article and Find Full Text PDFThromboembolism is a common concern in ventricular assist device (VAD) therapy. Precise VAD response to pass-through thromboembolism needs to be studied in a controlled in vitro setting where specific pump parameters (i.e.
View Article and Find Full Text PDFBackground: Deep Bleeder Acoustic Coagulation (DBAC) is an ultrasound image-guided high-intensity focused ultrasound (HIFU) method proposed to automatically detect and localize (D&L) and treat deep, bleeding, combat wounds in the limbs of soldiers. A prototype DBAC system consisting of an applicator and control unit was developed for testing on animals. To enhance control, and thus safety, of the ultimate human DBAC autonomous product system, a thermal coagulation strategy that minimized cavitation, boiling, and non-linear behaviors was used.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
August 2015
Aims: The aim of this study was to validate novel imaging technology for simultaneous morphological and biochemical endogenous optical imaging of coronary atherosclerotic plaque.
Methods And Results: Optical coherence tomography (OCT) generates high-resolution 3D images of plaque morphology and endogenous fluorescence lifetime imaging microscopy (FLIM) characterizes biochemical composition. Both imaging modalities rely on plaque's intrinsic optical characteristics, making contrast agents unnecessary.
Mechanical cardiac unloading with use of a left ventricular assist device (LVAD) is associated with substantial improvements in left ventricular function and enables subsequent LVAD explantation in some patients. We describe the case of a 35-year-old man with dilated nonischemic cardiomyopathy who was supported with an LVAD for 9 months. After the device was removed, he led a normal life for 13 years and 4 months.
View Article and Find Full Text PDFBackground: Glomerulonephropathies are common causes of kidney disease in dogs.
Objective: To determine the prevalence of immune-complex glomerulonephritis (ICGN) in North American dogs biopsied for suspected glomerular disease.
Animals: Renal biopsies (n = 733) submitted to the Texas Veterinary Renal Pathology Service between January 1, 2007 and December 31, 2012 were reviewed.
Background: Human renal biopsies are routinely evaluated with light microscopy (LM) using a panel of histologic stains, transmission electron microscopy (TEM), and immunofluorescence (IF) microscopy to obtain a diagnosis. In contrast, the pathologic evaluation of glomerular disease in veterinary medicine has relied mostly on LM and was of limited utility. To address this problem, recently established veterinary renal diagnostic centers have adopted methods used in human nephropathology for evaluation of renal biopsies.
View Article and Find Full Text PDFPDX1 (pancreatic and duodenal homeobox 1) is overexpressed in pancreatic cancer, and its reduction results in tumor regression. Bi-functional pbi-shRNA PDX1 nanoparticle (OFHIRNA-PDX1) utilizes the endogenous micro-RNA biogenesis pathway to effect cleavage- and non-cleavage-dependent degradation of PDX1 mRNA. We have shown that OFHIRNA-PDX1 reduces pancreatic tumor volume in xenograft models.
View Article and Find Full Text PDFA left atrial pressure (LAP) monitoring system was developed for guiding the management of patients with heart failure. The LAP sensor is implanted into the left atrium via transseptal catheterization and affixed to the interatrial septum by nitinol anchors. The long-term safety of permanent implantation of the LAP sensor in patients was evaluated based on the comparative pathology in animals.
View Article and Find Full Text PDFBackground: Chagas disease (Trypanosomiasis) is a cause of myocarditis in the southern United States causing cardiac conduction abnormalities, arrhythmias, and heart failure.
Objectives: To report clinical findings and outcome in Chagas positive (CP) dogs requiring pacemaker implantation for bradyarrhythmias.
Animals: One hundred and forty-four client-owned dogs requiring pacemaker implantation.
Cerebral aneurysms treated by traditional endovascular methods using platinum coils have a tendency to be unstable, either due to chronic inflammation, compaction of coils, or growth of the aneurysm. We propose to use alternate filling methods for the treatment of intracranial aneurysms using polyurethane-based shape memory polymer (SMP) foams. SMP polyurethane foams were surgically implanted in a porcine aneurysm model to determine biocompatibility, localized thrombogenicity, and their ability to serve as a stable filler material within an aneurysm.
View Article and Find Full Text PDFUnlabelled: Heart failure is a leading cause of death in human populations, and as people live longer, it is becoming an increasingly prominent problem. Because of the insufficient numbers of donor hearts, physicians and engineers are turning to mechanical circulatory support in the form of ventricular assist devices (VADs). Their clinical performance and increasing availability of various types, sizes, and functions are increasing VAD recognition.
View Article and Find Full Text PDF