Purpose: Hypothyroidism affects up to 21% of women with breast cancer after supraclavicular node irradiation. The PENTEC (pediatric normal tissue effects in the clinic) initiative highlighted the need to minimize the thyroid dose, albeit without giving a specific constraint. This study aimed to define a reasonable target thyroid mean dose (D) between 10 and 15 Gy using intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) and examine its impact on the hypothyroidism risk.
View Article and Find Full Text PDFIntroduction: Complement factor H (FH) is a major regulator of the complement alternative pathway, its mutations predispose to an uncontrolled activation in the kidney and on blood cells and to secondary C3 deficiency. Plasma exchange has been used to correct for FH deficiency and although the therapeutic potential of purified FH has been suggested by experiments in animal models, a clinical approved FH concentrate is not yet available. We aimed to develop a purification process of FH from a waste fraction rather than whole plasma allowing a more efficient and ethical use of blood and plasma donations.
View Article and Find Full Text PDFAim: Dental agenesis is one of the most frequent dental anomalies, with a prevalence varying from 1.6% to 36.5%, depending on the populations studied.
View Article and Find Full Text PDFPurpose: To investigate the role of infra diaphragmatic intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT) for female Hodgkin Lymphoma (HL) patients and to estimate the risk of secondary cancer and ovarian failure.
Methods: A comparative treatment planning study was performed on 14 patients, and the results were compared according to conventional dose-volume metrics. In addition, estimates of the excess absolute risk (EAR) of secondary cancer induction were determined for the bowel, the bladder and the rectum.
Background: To investigate the role of intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT) for the radiation treatment of thymoma cancer.
Methods: Twenty patients were retrospectively planned for IMPT [with (IMPT_R1 or IMPT_R2 according to the approach adopted) and without robust optimization] and VMAT. The results were compared according to dose-volume metrics on the clinical and planning target volumes (CTV and PTV) and the main organs at risk (heart, breasts, lungs, spinal cord and oesophagus).
Background: To investigate the role of intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT), realised with RapidArc and RapidPlan methods (RA_RP) for neoadjuvant radiotherapy in locally advanced oesophagal cancer.
Methods: Twenty patients were retrospectively planned for IMPT (with two fields, (IMPT_2F) or with three fields (IMPT_3F)) and RA_RP and the results were compared according to dose-volume metrics. Estimates of the excess absolute risk (EAR) of secondary cancer induction were determined for the lungs.
Hematopoietic stem cell transplant-related thrombotic microangiopathy (HSCT-TMA) is a severe complication whose pathophysiology is unknown. We describe 6 patients in which the disease was associated with complement regulatory gene abnormalities received from their respective donors. It is suggested that mutated and transplanted monocyte-derived cells are responsible for production of abnormal proteins, complement dysregulation, and, ultimately, for the disease.
View Article and Find Full Text PDFSeveral mutations have been identified in the gene coding for Complement Factor H (FH) from patients with atypical Hemolytic Uraemic Syndrome (aHUS), Age-related Macular Degeneration (AMD) and Membranoproliferative Glomerulonephritis (MPGN). These data allow for a precise description of the structural changes affecting FH, but a simple test for specifically assessing FH function routinely is not yet of common use. We have produced and characterised a monoclonal antibody (5H5) which discriminates between FH and the smaller FH-like 1 and FH-related proteins and show here that it specifically binds to FH without detecting the smaller isoforms.
View Article and Find Full Text PDFPurpose: To evaluate the performance of a model-based optimisation process for volumetric modulated arc therapy, VMAT, applied to whole breast irradiation.
Methods And Materials: A set of 150 VMAT dose plans with simultaneous integrated boost were selected to train a model for the prediction of dose-volume constraints. The dosimetric validation was done on different groups of patients from three institutes for single (50 cases) and bilateral breast (20 cases).
Background: To evaluate the performance of a broad scope model-based optimisation process for volumetric modulated arc therapy applied to esophageal cancer.
Methods And Materials: A set of 70 previously treated patients in two different institutions, were selected to train a model for the prediction of dose-volume constraints. The model was built with a broad-scope purpose, aiming to be effective for different dose prescriptions and tumour localisations.
Background: Machine Performance Check (MPC) is an application to verify geometry and beam performances of TrueBeam Linacs, through automated checks based on their kV-MV imaging systems. In this study, preliminary tests with MPC were analyzed using all photon beam energies of our TrueBeam, comparing whenever possible with external independent checks.
Methods: Data acquisition comprises a series of 39 images (12 with kV and 27 with MV detector) acquired at predefined positions without and with the IsoCal phantom in the beam, and with particular MLC pattern settings.
Purpose: To evaluate the performance of a model-based optimisation process for volumetric modulated arc therapy applied to advanced lung cancer and to low risk prostate carcinoma patients.
Methods And Materials: Two sets each of 27 previously treated patients, were selected to train models for the prediction of dose-volume constraints. The models were validated on the same sets of plans (closed-loop) and on further two sets each of 25 patients not used for the training (open-loop).
Background: To evaluate in-silico the performance of a model-based optimization process for volumetric modulated arc therapy (RapidArc) applied to hepatocellular cancer treatments.
Patients And Methods: 45 clinically accepted RA plans were selected to train a knowledge-based engine for the prediction of individualized dose-volume constraints. The model was validated on the same plans used for training (closed-loop) and on a set of other 25 plans not used for the training (open-loop).
Background: To appraise the robustness of VMAT dose distributions against uncertainties in the positioning of the patients when single fraction SABRT treatments are planned.
Methods: A set of 18 patients (8 lung, 5 brain, 5 spinal or para-spinal) treated with VMAT in a single fraction of 24Gy were retrospectively analyzed. All approved plans were re-calculated by applying shifts to the isocentre of ±0.
Purpose: Phase-space files for Monte Carlo simulation of the Varian TrueBeam beams have been made available by Varian. The aim of this study is to evaluate the accuracy of the distributed phase-space files for flattening filter free (FFF) beams, against experimental measurements from ten TrueBeam Linacs.
Methods: The phase-space files have been used as input in PRIMO, a recently released Monte Carlo program based on the PENELOPE code.
Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels.
Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters.
Purpose: To demonstrate the feasibility of portal dosimetry with an amorphous silicon mega voltage imager for flattening filter free (FFF) photon beams by means of the GLAaS methodology and to validate it for pretreatment quality assurance of volumetric modulated arc therapy (RapidArc).
Methods: The GLAaS algorithm, developed for flattened beams, was applied to FFF beams of nominal energy of 6 and 10 MV generated by a Varian TrueBeam (TB). The amorphous silicon electronic portal imager [named mega voltage imager (MVI) on TB] was used to generate integrated images that were converted into matrices of absorbed dose to water.
Aims: To retrospectively evaluate and compare the incidence of acute genitourinary (aGU), upper gastrointestinal (uGI) and rectal (lGI) injuries after radiotherapy with hypo-fractionation by volumetric modulation arc therapy (VMAT, the Hypo-RapidArc group) and conventional fractionation by three-dimensional conformal radiotherapy (3DCRT) in patients with localized prostate cancer treated, after radical prostatectomy, with prostatic bed irradiation.
Patients And Methods: Between 2007 and 2012, 84 consecutive patients with clinically localized prostate cancer submitted to radical prostatectomy were also treated with irradiation to the prostate bed. Forty-five received 3DCRT and 39 Hypo-RapidArc.
Int J Radiat Oncol Biol Phys
December 2013
Purpose: To evaluate intensity modulated proton therapy (IMPT) in patients with cervical cancer in terms of coverage, conformity, and dose-volume histogram (DVH) parameters correlated with recommendations from magnetic resonance imaging (MRI)-guided brachytherapy.
Methods And Materials: Eleven patients with histologically proven cervical cancer underwent primary chemoradiation for the pelvic lymph nodes, the uterus, the cervix, and the parametric region, with a symmetric margin of 1 cm. The prescription was for 50.
Purpose: The accuracy of photon dose calculation algorithms in out-of-field regions is often neglected, despite its importance for organs at risk and peripheral dose evaluation. The present work has assessed this for the anisotropic analytical algorithm (AAA) and the Acuros-XB algorithms implemented in the Eclipse treatment planning system. Specifically, the regions shielded by the jaw, or the MLC, or both MLC and jaw for flattened and unflattened beams have been studied.
View Article and Find Full Text PDFBackground: The accuracy of the two dose calculation engines available for RapidArc planning (both released for clinical use) is investigated in comparison to the COMPASS data.
Methods: Two dose calculation algorithms (Acuros-XB and Anisotropic Analytic Algorithm (AAA)) were used to calculate RA plans and compared to calculations with the Collapsed Cone Convolution algorithm (CC) from the COMPASS system (IBA Dosimetry). CC calculations, performed on patient data, are based on experimental fluence measurements with a 2D array of ion chambers mounted on the linac head.
Objective: To evaluate the use of volumetric-modulated arc therapy [VMAT, RapidArc® (RA); Varian Medical Systems, Palo Alto, CA] for the treatment of cutaneous Kaposi's sarcoma (KS) of lower extremities with adequate target coverage and high bone sparing, and to compare VMAT with electron beam therapy.
Methods: 10 patients were planned with either RA or electron beams. The dose was prescribed to 30 Gy, 10 fractions, to mean the planning target volume (PTV), and significant maximum dose to bone was limited to 30 Gy.
Purpose: Complex radiotherapy fields delivered using a tertiary multileaf collimator (MLC) often feature small open segments surrounded by large areas of the beam only shielded by the MLC. The aim of this study was to test the ability of two modern dose calculation algorithms to accurately calculate the dose in these fields which would be common, for example, in volumetric modulated arc treatment (VMAT) and study the impact of variations in dosimetric leaf gap (DLG), focal spot size, and MLC transmission in the beam models.
Methods: Nine test fields with small fields (0.
Background: SBRT is a safe and efficient strategy to locally control multiple metastatic sites. While research in the physics domain for Flattening Filter Free Beams (FFF) beams is increasing, there are few clinical data of FFF beams in clinical practice. Here we reported dosimentric and early clinical data of SBRT and FFF delivery in isolated lymph node oligometastatic patients.
View Article and Find Full Text PDF