Publications by authors named "Clifford Franklin"

Purpose:  Mismatch negativity (MMN) reflects a preperceptual neurophysiological response that is generated subconsciously due to the interruption of a memory trace of ongoing sensory events in the environment. It has been widely used by researchers to understand complex perceptual mechanisms. Furthermore, it has been recommended as an objective tool to investigate disorders related to auditory cognition in hearing aid and cochlear implant users.

View Article and Find Full Text PDF

Background: Frequencies of normal and abnormal heart sounds have previously been reported, but the acoustic analyses of the frequency responses of conventional and amplified stethoscopes for different heart sounds have not yet been reported.

Objectives: To compare the acoustic analysis of frequency responses of three stethoscopes (conventional and amplified) for measuring simulated heart sounds.

Materials And Methods: This exploratory study used Starkey SLI-ST3, Cardionics E-Scope II (both electronic) and Littmann Classic S.

View Article and Find Full Text PDF

Purpose: The primary purpose of this study was to test the effect of the combined use of trained standardized parents and a baby simulator on students' hearing screening and parental counseling knowledge and skills.

Method: A one-group pretest-posttest quasi-experimental study design was used to assess self-ratings of confidence in knowledge and skills and satisfaction of the educational experience with standardized parents and a baby simulator. The mean age of the 14 audiology students participating in this study was 24.

View Article and Find Full Text PDF

The present study was a follow-up investigation to a previous study exploring the relationship between listeners' loudness tolerance and listeners' acceptable noise level among normally hearing adults. The present study compared the same two measures, but data were obtained from listeners with hearing loss; 12 adults with sensorineural hearing loss participated in a loudness tolerance measure using a scaling technique initially established for setting hearing aid output limits, in addition to an acceptable noise level measure. The acceptable noise level procedure used in this study quantified the listeners' acceptance of background noise while listening to speech.

View Article and Find Full Text PDF

Background: The acceptable noise level (ANL) indicates how much background noise a listener is willing to accept while listening to speech. The clinical impact and application of the ANL measure is as a predictor of hearing-aid use. The ANL may also correlate with the percentage of time spent in different listening environments (i.

View Article and Find Full Text PDF
Article Synopsis
  • Health care professionals, including audiologists, are held to strict ethical standards, with a Code of Ethics set by the American Academy of Audiology that applies to both practicing and student members.
  • An online survey of 143 audiology students explored their perceptions of their preceptors' adherence to eight ethical principles, revealing a strong belief that these preceptors follow ethical guidelines.
  • Students feel that while preceptors are ethical, the responsibility for teaching ethics mainly lies with academic faculty rather than the preceptors themselves, suggesting a need for further research on ethics education in audiology.
View Article and Find Full Text PDF

Background: The acceptable noise level (ANL) measure is an indicator of hearing aid use. The majority of research in this area has focused primarily on adults. Research using school-aged listeners, specifically 8 and 12 yr old children, demonstrated that the average ANL values, standard deviations (SDs), and distribution of ANL values for these children were similar to those of adult listeners.

View Article and Find Full Text PDF

This study investigated the relationship between listener loudness tolerance and listener acceptable noise level (ANL). Twenty-five normal hearing adults completed loudness tolerance and acceptable noise level measures. Loudness tolerance was measured using a scaling technique.

View Article and Find Full Text PDF

Purpose: Pulsed and warbled tones are suitable substitutions for pure tones in hearing threshold measurement according to the 2005 American Speech-Language-Hearing Association guidelines. These guidelines also recommend measuring thresholds at 3000 and 6000 Hz. To date, there is no research directly supporting substitution of pulsed or warbled tones for pure tones at 3000 and 6000 Hz for listeners with normal hearing or with hearing loss.

View Article and Find Full Text PDF

Objective: American Speech-Language-Hearing Association (ASHA) guidelines allow pulsed and warbled tones in measuring audiometric thresholds and include test frequencies of 3000 and 6000 Hz. However, no research has examined the relationship between thresholds obtained with these stimuli at these frequencies. This study investigated the relationship between thresholds obtained with pulsed, warbled, and pulsed-warbled tones.

View Article and Find Full Text PDF

A method has been established to measure the maximum acceptable background noise level (BNL) for a listener, while listening to speech at the most comfortable listening level (MCL). The acceptable noise level (ANL) is the difference between BNL and MCL. In the present study, the ANL procedure was used to measure acceptance of noise, first, in the presence of speech at MCL and, then, for speech presented at much lower and higher levels in listeners with normal hearing.

View Article and Find Full Text PDF