Background: The current literature suggests that emergency physician (EP)-performed limited compression ultrasound (LCUS) is a rapid and accurate test for deep vein thrombosis (DVT).
Objective: Our primary objective was to determine the sensitivity and specificity of LCUS for the diagnosis of DVT when performed by a large heterogeneous group of EPs.
Methods: This was a prospective diagnostic test assessment of LCUS conducted at two urban academic emergency departments.