Publications by authors named "Clausse A"

Plasma Foci are pulsed coaxial discharges with numerous radiation applications and interesting scientific phenomena. Although the physics answered much of the processes involved in these discharges, many related fundamental questions still remains doggedly unresolved. One of the obstacles to deeper knowledge is the scarcity of reliable experimental data.

View Article and Find Full Text PDF
Article Synopsis
  • An experiment was conducted using a rectangular channel with four inclined cylindrical rods to measure pressures and pressure drops while varying the rods' angles.
  • The study involved testing three different diameters of rods and applying momentum conservation principles to analyze the data, resulting in dimensionless parameter groups relating pressure to rod characteristics.
  • The findings confirmed that the independence principle applies to most Euler numbers, showing that pressure measurements remain consistent regardless of inclination when normalized by the inlet velocity vertical to the rods, aiding in the design of similar hydraulic systems.
View Article and Find Full Text PDF

Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication.

Study Design: Research and development study.

Animals: A domestic cat.

View Article and Find Full Text PDF

We perform a nonlinear analysis of a fluid-fluid wavy-stratified flow using a simplified two-fluid model (TFM), i.e., the fixed-flux model (FFM), which is an adaptation of the shallow water theory for the two-layer problem.

View Article and Find Full Text PDF

Purpose: Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously explored as potential biomarkers of DR, yet the current literature is inconclusive with respect to their correlation with PDR.

View Article and Find Full Text PDF

The interest in lattice-Boltzmann models in the computational hemodynamics realm has increased in recent years. In this context, the correct choice of numerical parameters for the appropriate simulation of blood flows in major arteries is a crucial aspect. For this reason, we present three parameter-tuning strategies that allow us to reproduce correctly the pulsatile time-dependent flow of an incompressible fluid under physiological regimes.

View Article and Find Full Text PDF

A method to infer the current density distribution in the current sheath of a plasma focus discharge from a magnetic probe is formulated and then applied to experimental data obtained in a 1.1 kJ device. Distortions on the magnetic probe signal caused by current redistribution and by a time-dependent total discharge current are considered simultaneously, leading to an integral equation for the current density.

View Article and Find Full Text PDF

Image segmentation of 3D medical images is a challenging problem with several still not totally solved practical issues, such as noise interference, variable object structures and image artifacts. This paper describes a hybrid 3D image segmentation method which combines region growing and deformable models to obtain accurate and topologically preserving surface structures of anatomical objects of interest. The proposed strategy starts by determining a rough but robust approximation of the objects using a region-growing algorithm.

View Article and Find Full Text PDF

A new flow methodology exploiting the multi-pumping approach was developed for the spectrophotometric determination of ambroxol hydrochloride in pharmaceutical preparations. The flow manifold was implemented by using, exclusively, multiple solenoid-actuated micro-pumps, which acted simultaneously as sample insertion, solutions propelling and reagents commutation units. Linear calibration plots were obtained over an ambroxol concentration ranging from 10 to 200 mg l(-1) (r.

View Article and Find Full Text PDF

A modification of the serum gentamicin immunoenzymatic method (Syva- Biom erieux kit) for sisomicin assay is proposed and compared to the bacteriological reference method. It shows a higher sensitivity (0.1 mg.

View Article and Find Full Text PDF