Publications by authors named "Claus Fink Jepsen"

Background: Implant fractures are a very rare complication in primary total knee replacement (TKR) surgery and with modern implant designs and improved metals these events have nearly been eliminated. In this case series we report three cases of tibial metal baseplate fractures in uncemented Regenerex® TKR.

Methods: Cases originated from a prospective case series of 80 patients operated between 2013 and 2016.

View Article and Find Full Text PDF

Background and purpose - The stem on the tibial component of total knee arthroplasty provides mechanical resistance to lift-off, shear forces, and torque. We compared tibial components with finned stems (FS) and I-beam block stems (IS) to assess differences in implant migration. Patients and methods - In a patient-blinded RCT, 54 patients/knees (15 men) with knee osteoarthritis at a mean age of 77 years (70-90) were randomly allocated to receive tibial components with either a FS (n = 27) or an IS (n = 27).

View Article and Find Full Text PDF

Background and purpose - Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA).

View Article and Find Full Text PDF

Background And Purpose: There is disagreement in the literature about the importance of patellofemoral joint degeneration and knee pain for the outcome of unicompartmental knee arthroplasty (UKA). We therefore investigated the importance of selected predictors including patellofemoral joint degeneration and the location of preoperative knee pain for the early outcome of UKA.

Patients And Methods: The study group comprised 260 consecutive patients from 5 hospitals who underwent Oxford UKA for anteromedial osteoarthritis.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate whether a change in the femoral graft insertion site between the 1-o'clock (high) and 2-o'clock (low) positions could change the laxity, the score on the 2000 International Knee Documentation Committee (IKDC) Knee Examination Form, or the score on the 2000 subjective IKDC Knee Evaluation Form in the anterior cruciate ligament (ACL)-reconstructed knee.

Methods: The study was designed as a prospective, randomized, double-blind investigation. We randomized 30 patients to the low tunnel position group and 30 to the high tunnel position group.