Publications by authors named "Claudia S A Lipke"

Unlabelled: The aim of the study was to validate the accuracy of the EXINI heart software (EXINI) package in assessing left ventricular end-diastolic/systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-MIBI single-photon emission tomography (SPECT). Cardiac magnetic resonance imaging (cMRI) was used as reference. Furthermore, effects of perfusion defects and image quality in SPECT on correlation between gated SPECT and magnetic resonance imaging were investigated.

View Article and Find Full Text PDF

The aim of this study was to investigate the value of a real-time magnetic resonance imaging (MRI) approach for the assessment of left-ventricular-wall motion in patients with insufficient transthoracic echocardiography in terms of accuracy and temporal expenditure. Twenty-five consecutive patients were examined on a 1.5-Tesla whole-body MR system (ACS-NT, Philips Medical Systems, Best, NL) using a real-time and ECG-gated (the current gold standard) steady-state free-precession (SSFP) sequence.

View Article and Find Full Text PDF

Purpose: The segmentation algorithm ESM based on an elastic surface model was validated for the assessment of left ventricular volumes and ejection fraction from ECG-gated myocardial perfusion SPECT. Additionally, it was compared with the commercially available quantification packages 4D-MSPECT and QGS. Cardiac MRI was used as the reference method.

View Article and Find Full Text PDF

Aims: The aim of the study was to compare, in patients with chronic ischaemic cardiomyopathy, contrast-enhanced cardiovascular magnetic resonance (ce-CMR) imaging and a combined (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and (99m)Tc-sestamibi single-photon emission computed tomography (SPECT) protocols for the prediction of functional recovery after revascularization, as assessed by cine CMR.

Methods And Results: Twenty-nine patients with ischaemic cardiomyopathy (ejection fraction 32 +/- 10%) were investigated with ce-CMR and PET/SPECT. For the assessment of global and regional functions, cine CMR was performed at baseline and at 6 months follow-up.

View Article and Find Full Text PDF

Unlabelled: The goal of this study was to validate the accuracy of the Emory Cardiac Tool Box (ECTB) in assessing left ventricular end-diastolic or end-systolic volume (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT using cardiac MRI (cMRI) as a reference. Furthermore, software-specific characteristics of ECTB were analyzed in comparison with 4D-MSPECT and Quantitative Gated SPECT (QGS) results (all relative to cMRI).

Methods: Seventy patients with suspected or known coronary artery disease were examined using gated (99m)Tc-MIBI SPECT (8 gates/cardiac cycle) 60 min after tracer injection at rest.

View Article and Find Full Text PDF

Unlabelled: Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET.

Methods: Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated (18)F-FDG PET using QGS and 4D-MSPECT.

View Article and Find Full Text PDF

The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography ((99m)Tc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated (99m)Tc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest.

View Article and Find Full Text PDF

The aim of this study was to validate the estimation of left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) as well as wall motion analysis from gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in patients with severe coronary artery disease (CAD) using software originally designed for gated single-photon emission tomography (SPET). Thirty patients with severe CAD referred for myocardial viability diagnostics were investigated using a standard FDG PET protocol enhanced with gated acquisition (8 gates per cardiac cycle). EDV, ESV and LVEF were calculated using standard software designed for gated SPET (QGS).

View Article and Find Full Text PDF